510(k) Report

510(k) · Cleared

Cleared

Cannulated Screw System

K233396510(k) TraditionalCleared Dec 21, 202379-day reviewClass II21 CFR 888.3040

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Smith & Nephew, Inc. · HWC Screw, Fixation, Bone

Cleared on Dec 21, 2023 as substantially equivalent to K090675 (Smith & Nephew, Inc., 2009) and 2 other predicates after a 79-day review. Its family tree reaches back 15 generations to 1996.

Decided
Dec 21, 2023
Review
79 days
Class
Class II
Product code
HWC
Recalls
None
Predicates
3

Its longest line of descent runs back 15 generations to K962616 (1996). 235 ancestors in all, the oldest K792022 (1979). No later device cites it as a predicate yet.

Other ancestors, by year cleared 2011: 4 other ancestors2009: 7 other ancestors2021: 1 other ancestor2020: 3 other ancestors2019: 1 other ancestor2018: 1 other ancestor2017: 3 other ancestors2016: 3 other ancestors2015: 1 other ancestor2014: 5 other ancestors2012: 1 other ancestor2010: 6 other ancestors2008: 7 other ancestors2007: 7 other ancestors2006: 12 other ancestors2005: 12 other ancestors2003: 7 other ancestors2002: 18 other ancestors2001: 18 other ancestors1999: 8 other ancestors1996: 14 other ancestors1995: 12 other ancestors1994: 7 other ancestors2004: 11 other ancestors2000: 14 other ancestors1997: 9 other ancestors1990: 3 other ancestors1982: 1 other ancestor1979: 1 other ancestor1998: 12 other ancestors1993: 3 other ancestors1991: 1 other ancestor1989: 2 other ancestors1988: 1 other ancestor1984: 1 other ancestor1992: 2 other ancestors1985: 1 other ancestorK962616 · Synthes Dorsal Distal Radius Plate (DDRP) System · Synthes (Usa) · 1996K982732 · Synthes (Usa) Distal Radius Plate System (DRPS) · Synthes · 1998×3: 3 generations cleared close together, K023007 (2002), K030198 (2003), K032705 (2003) ×2: 2 generations cleared close together, K050932 (2005), K051735 (2005) K061352 · Peri-Loc Periarticular Locked Plating System for the Upper Extremity · Smith & Nephew, Inc. · 2006×2: 2 generations cleared close together, K082516 (2008), K083032 (2009) K123055 · Smith & Nephew, Inc Screw and Plate System Instrumentation · Smith & Nephew, Inc. · 2013K140814 · Evos Mini-Fragment Plating System · Smith & Nephew, Inc. · 2014 · recalledK181533 · EVOS Wrist Fracture Plating System · Smith & Nephew, Inc. · 2018K210837 · Smith & Nephew Plates and Screws · Smith & Nephew, Inc. · 2021 · recalledK213126 · Smith & Nephew, Inc. Plates and Screws Systems: EVOS, Peri-Loc, D-Rad, TC-100, VLP Mini-Mod, Compression Hip Screw (CHS), CONQUEST FN, and cannulated screws · Smith & Nephew, Inc. · 2022 · recalled19801990200020102020
Other ancestors, by generation 1 generation back: 2 other ancestors2 generations back: 42 other ancestors3 generations back: 48 other ancestors4 generations back: 49 other ancestors5 generations back: 34 other ancestors6 generations back: 23 other ancestors7 generations back: 13 other ancestors8 generations back: 6 other ancestors9 generations back: 2 other ancestors10 generations back: 1 other ancestor K213126 · Smith & Nephew, Inc. Plates and Screws Systems: EVOS, Peri-Loc, D-Rad, TC-100, VLP Mini-Mod, Compression Hip Screw (CHS), CONQUEST FN, and cannulated screws · Smith & Nephew, Inc. · 2022 · recalledK210837 · Smith & Nephew Plates and Screws · Smith & Nephew, Inc. · 2021 · recalledK181533 · EVOS Wrist Fracture Plating System · Smith & Nephew, Inc. · 2018K140814 · Evos Mini-Fragment Plating System · Smith & Nephew, Inc. · 2014 · recalledK123055 · Smith & Nephew, Inc Screw and Plate System Instrumentation · Smith & Nephew, Inc. · 2013K083032 · Peri-Loc Bone Plating and Screw System · Smith & Nephew, Inc. · 2009 · recalledK082516 · Peri-Loc Periarticular Locked Plating System Hexalobular Bone Screws · Smith & Nephew, Inc. · 2008K061352 · Peri-Loc Periarticular Locked Plating System for the Upper Extremity · Smith & Nephew, Inc. · 2006K051735 · Peri-Loc Locking Bone Plates and Locking Bone Screws for the Upper Extremity · Smith & Nephew, Inc. · 2005K050932 · Distal Volar Radius Anatomical Plate System · Hand Innovations, Inc. · 2005 · recalledK032705 · Distal Radius Fracture Repair System · Hand Innovations, Inc. · 2003K030198 · Hand Innovations, Inc. Distal Radius Fracture Repair System · Hand Innovations, Inc. · 2003K023007 · Distal Radius Fracture Repair System · Hand Innovations, Inc. · 2002K982732 · Synthes (Usa) Distal Radius Plate System (DRPS) · Synthes · 1998K962616 · Synthes Dorsal Distal Radius Plate (DDRP) System · Synthes (Usa) · 1996−15−10−50
  1. Root · 15 generations backK962616 Synthes Dorsal Distal Radius Plate (DDRP) SystemSynthes (Usa) · 1996
  2. 11 generations between
  3. 3 generations backK181533 EVOS Wrist Fracture Plating SystemSmith & Nephew, Inc. · 2018
  4. 2 generations backK210837 Smith & Nephew Plates and ScrewsSmith & Nephew, Inc. · 2021 · Recalled
  5. 1 generation backK213126 Smith & Nephew, Inc. Plates and Screws Systems: EVOS, Peri-Loc…Smith & Nephew, Inc. · 2022 · Recalled
  6. This deviceK233396 Cannulated Screw SystemSmith & Nephew, Inc. · 2023
Show all 15 generations
  1. Root · 15 generations backK962616 Synthes Dorsal Distal Radius Plate (DDRP) SystemSynthes (Usa) · 1996
  2. 14 generations backK982732 Synthes (Usa) Distal Radius Plate System (DRPS)Synthes · 1998
  3. 13 generations backK023007 Distal Radius Fracture Repair SystemHand Innovations, Inc. · 2002
  4. 12 generations backK030198 Hand Innovations, Inc. Distal Radius Fracture Repair SystemHand Innovations, Inc. · 2003
  5. 11 generations backK032705 Distal Radius Fracture Repair SystemHand Innovations, Inc. · 2003
  6. 10 generations backK050932 Distal Volar Radius Anatomical Plate SystemHand Innovations, Inc. · 2005 · Recalled
  7. 9 generations backK051735 Peri-Loc Locking Bone Plates and Locking Bone Screws for the Upper…Smith & Nephew, Inc. · 2005
  8. 8 generations backK061352 Peri-Loc Periarticular Locked Plating System for the Upper ExtremitySmith & Nephew, Inc. · 2006
  9. 7 generations backK082516 Peri-Loc Periarticular Locked Plating System Hexalobular Bone ScrewsSmith & Nephew, Inc. · 2008
  10. 6 generations backK083032 Peri-Loc Bone Plating and Screw SystemSmith & Nephew, Inc. · 2009 · Recalled
  11. 5 generations backK123055 Smith & Nephew, Inc Screw and Plate System InstrumentationSmith & Nephew, Inc. · 2013
  12. 4 generations backK140814 Evos Mini-Fragment Plating SystemSmith & Nephew, Inc. · 2014 · Recalled
  13. 3 generations backK181533 EVOS Wrist Fracture Plating SystemSmith & Nephew, Inc. · 2018
  14. 2 generations backK210837 Smith & Nephew Plates and ScrewsSmith & Nephew, Inc. · 2021 · Recalled
  15. 1 generation backK213126 Smith & Nephew, Inc. Plates and Screws Systems: EVOS, Peri-Loc…Smith & Nephew, Inc. · 2022 · Recalled
  16. This deviceK233396 Cannulated Screw SystemSmith & Nephew, Inc. · 2023
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−15K962616Synthes Dorsal Distal Radius Plate (DDRP) SystemSynthes (Usa)1996—
−14K982732Synthes (Usa) Distal Radius Plate System (DRPS)Synthes1998—
−13K023007Distal Radius Fracture Repair SystemHand Innovations, Inc.2002—
−12K030198Hand Innovations, Inc. Distal Radius Fracture Repair SystemHand Innovations, Inc.2003—
−11K032705Distal Radius Fracture Repair SystemHand Innovations, Inc.2003—
−10K050932Distal Volar Radius Anatomical Plate SystemHand Innovations, Inc.20051
−9K051735Peri-Loc Locking Bone Plates and Locking Bone Screws for the Upper ExtremitySmith & Nephew, Inc.2005—
−8K061352Peri-Loc Periarticular Locked Plating System for the Upper ExtremitySmith & Nephew, Inc.2006—
−7K082516Peri-Loc Periarticular Locked Plating System Hexalobular Bone ScrewsSmith & Nephew, Inc.2008—
−6K083032Peri-Loc Bone Plating and Screw SystemSmith & Nephew, Inc.20092
−5K123055Smith & Nephew, Inc Screw and Plate System InstrumentationSmith & Nephew, Inc.2013—
−4K140814Evos Mini-Fragment Plating SystemSmith & Nephew, Inc.20142
−3K181533EVOS Wrist Fracture Plating SystemSmith & Nephew, Inc.2018—
−2K210837Smith & Nephew Plates and ScrewsSmith & Nephew, Inc.20211
−1K213126Smith & Nephew, Inc. Plates and Screws Systems: EVOS, Peri-Loc, D-Rad, TC-100…Smith & Nephew, Inc.20221
0 (this device)K233396Cannulated Screw SystemSmith & Nephew, Inc.2023—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
197910
198210
198410
198510
198810
198920
199030
199110
199220
199330
199470
1995120
1996140
199790
1998120
199980
2000140
2001180
2002180
200370
2004110
2005120
2006120
200770
200870
200970
201060
201140
201210
201450
201510
201630
201730
201810
201910
202030
202110
FIG. 1 — Lineage of K233396, 1996–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HWC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HWC device

  1. #1 K203011 Monster Screw Systemscore 22.2 · 14 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K090675Smith & Nephew, Inc. VLP Foot Plating, Screw System and Accessories
Summary page 4
…oduct Code HWC (primary), HTN I Legally Marketed Predicate Devices 21 CFR 807.92(a)(3) Predicate # Predicate Trade Name (Primary Predicate is listed first) Product Code K090675 Smith & Nephew, Inc. VLP Foot Plating, Screw System and Accg | HWC K111994 Smith & Nephew Cannulated Screws and Washers HWC K2131…
Smith & Nephew, Inc.2009—
*K111994Smith & Nephew Cannulated Screws and Washers
Summary page 4
…807.92(a)(3) Predicate # Predicate Trade Name (Primary Predicate is listed first) Product Code K090675 Smith & Nephew, Inc. VLP Foot Plating, Screw System and Accg | HWC K111994 Smith & Nephew Cannulated Screws and Washers HWC K213126 Smith & Nephew, Inc. Plates and Screws Systems HWC Device Description Su…
Smith & Nephew, Inc.2011—
*K213126Smith & Nephew, Inc. Plates and Screws Systems: EVOS, Peri-Loc, D-Rad, TC-100, VLP…
Summary page 4
…edicate is listed first) Product Code K090675 Smith & Nephew, Inc. VLP Foot Plating, Screw System and Accg | HWC K111994 Smith & Nephew Cannulated Screws and Washers HWC K213126 Smith & Nephew, Inc. Plates and Screws Systems HWC Device Description Summary 21 CFR 807.92(a)(4) The purpose of this Traditiona…
Smith & Nephew, Inc.20221

Also cleared against K090675: 22 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 27 years and passes through 4 companies; a new generation was cleared every 1.3 years on median.
  • 46 of the 235 ancestors have a recall of any class.
  • 22 other devices also cite its predicate K090675.

How does its category compare?

All HWC devices

HWC Screw, Fixation, Bone: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.

FDA decisions per year · HWC

15in 2025

2007: 352008: 332009: 272010: 232011: 352012: 202013: 252014: 312015: 412016: 262017: 402018: 202019: 302020: 282021: 262022: 262023: 242024: 172025: 152026 (partial year): 21
2007high 41 (2015) · low 15 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HWC

111in 2025

2007: 77 days median2008: 76 days median2009: 113 days median2010: 110 days median2011: 88 days median2012: 99 days median2013: 90 days median2014: 88 days median2015: 85 days median2016: 131 days median2017: 127 days median2018: 106 days median2019: 108 days median2020: 75 days median2021: 84 days median2022: 167 days median2023: 104 days median2024: 90 days median2025: 111 days median2026 (partial year): 125 days median
2007high 167 (2022) · low 75 (2020)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HWC

1in 2025

2007: 252008: 332009: 292010: 72011: 122012: 302013: 142014: 22015: 52016: 42017: 42018: 12019: 52020: 42021: 22022: 132025: 12026 (partial year): 2
2007high 33 (2008) · low 0 (2023)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HWC

2,893in 2025

2007: 6692008: 6602009: 6512010: 7652011: 1,1042012: 3,3392013: 3,8502014: 2,5492015: 2,7112016: 2,2852017: 2,5612018: 3,6622019: 5,4632020: 4,8202021: 4,4462022: 3,9342023: 3,7182024: 3,5752025: 2,893
2007high 5,463 (2019) · low 651 (2009)2025

MAUDE reports naming product code HWC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007357725669
2008337633660
20092711329651
2010231107765
20113588121,104
20122099303,339
20132590143,850
2014318822,549
2015418552,711
20162613142,285
20174012742,561
20182010613,662
20193010855,463
2020287544,820
2021268424,446
202226167133,934
20232410403,718
2024179003,575
20251511112,893
2026211252—

What is it indicated for?

The 4.0 mm Cannulated Screws and associated washers are indicated for arthrodesis and osteotomies of small bones and small joints, and ankle fracture. The 5.5 mm, 6.5 mm, 7.0 mm, and 8.0 mm Cannulated Screws, Cannulated Hip Pins and associated washers are indicated for fracture fixation, osteotomy, and arthrodesis of various bones and bone fragments appropriate for the size of the device. The Smith & Nephew 2.5 mm, 3.0 mm Cannulated and 3.0 mm Headless…

Read the full statement (117 words)

The 4.0 mm Cannulated Screws and associated washers are indicated for arthrodesis and osteotomies of small bones and small joints, and ankle fracture.

The 5.5 mm, 6.5 mm, 7.0 mm, and 8.0 mm Cannulated Screws, Cannulated Hip Pins and associated washers are indicated for fracture fixation, osteotomy, and arthrodesis of various bones and bone fragments appropriate for the size of the device.

The Smith & Nephew 2.5 mm, 3.0 mm Cannulated and 3.0 mm Headless Compression Screws are indicated for fixation of fractures, bunionectomies and osteotomies of small bones, and arthrodesis of small joints.

The Smith & Nephew 2.0 mm QFX Screw is indicated for osteotomies of the lesser metatarsals, and osteotomies and fractures of the phalanges.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K233396: Cannulated Screw System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K233396

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026