510(k) Report

510(k) · Cleared

Cleared

Raydent SW

K233625510(k) TraditionalCleared May 16, 2024185-day reviewClass II21 CFR 872.5470

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Ray Co., Ltd. · PNN Orthodontic Software

Cleared on May 16, 2024 as substantially equivalent to K180941 (3Shape A/S, 2018) and 1 other predicate after a 185-day review. Its family tree reaches back 4 generations to 2009. 2 later devices descend from it.

Decided
May 16, 2024
Review
185 days
Class
Class II
Product code
PNN
Recalls
None
Predicates
2

Its longest line of descent runs back 4 generations to K082207 (2009). 5 ancestors in all. 2 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2018: 1 other ancestor2025: 1 descendant cleared2026: 1 descendant clearedK082207 · Orthocad IQ · Cadent, Inc. · 2009K152086 · 3Shape Ortho System · 3Shape A/S · 2016K171295 · ULab Systems Treatment Planning Software · Ulab Systems, Inc. · 2018K180941 · Ortho System · 3Shape A/S · 201820052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor 1 generation forward: 2 descendants K180941 · Ortho System · 3Shape A/S · 2018K171295 · ULab Systems Treatment Planning Software · Ulab Systems, Inc. · 2018K152086 · 3Shape Ortho System · 3Shape A/S · 2016K082207 · Orthocad IQ · Cadent, Inc. · 20090
  1. Root · 4 generations backK082207 Orthocad IQCadent, Inc. · 2009
  2. 3 generations backK152086 3Shape Ortho System3Shape A/S · 2016
  3. 2 generations backK171295 ULab Systems Treatment Planning SoftwareUlab Systems, Inc. · 2018
  4. 1 generation backK180941 Ortho System3Shape A/S · 2018
  5. This deviceK233625 Raydent SWRay Co., Ltd. · 2024
  6. Descendant · cites it directly · 0 of its ownK260419 LingOral Dental Design SystemHangzhou ChohoTech Co., Ltd. · 2026
  7. Descendant · cites it directly · 0 of its ownK253343 Celebrace SoftwareCelebrace · 2025

Most influential descendants

Showing 2 of 2 · See all
  • K260419LingOral Dental Design SystemHangzhou ChohoTech Co., Ltd. · 2026 · cites it directly0descendants
  • K253343Celebrace SoftwareCelebrace · 2025 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K082207Orthocad IQCadent, Inc.2009—
−3K1520863Shape Ortho System3Shape A/S2016—
−2K171295ULab Systems Treatment Planning SoftwareUlab Systems, Inc.2018—
−1K180941Ortho System3Shape A/S2018—
0 (this device)K233625Raydent SWRay Co., Ltd.2024—
+1K260419LingOral Dental Design SystemHangzhou ChohoTech Co., Ltd.2026—
+1K253343Celebrace SoftwareCelebrace2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
201810

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202510
202610
FIG. 1 — Lineage of K233625, 2009–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in PNN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new PNN device

  1. #1 K262196 Invisalign Systemscore 14.5 · 9 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K180941Ortho System
Summary page 6
…CEREC Ortho Software ChairsideCAD Manufacturer 3Shape A/S Dentsply Sirona EXOCAD GMBH K180941 K171122 Exemption from 510(K) Number Traditional 510k T…
3Shape A/S2018—
*K171122CEREC Ortho Software
Summary page 6
…ChairsideCAD Manufacturer 3Shape A/S Dentsply Sirona EXOCAD GMBH K180941 K171122 Exemption from 510(K) Number Traditional 510k Traditional 510k Prema…
Dentsply Sirona2018—

Also cleared against K180941: 4 other devices →

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K260419LingOral Dental Design SystemHangzhou ChohoTech Co., Ltd.20260
K253343Celebrace SoftwareCelebrace20250

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 15 years and passes through 4 companies; a new generation was cleared every 5.6 years on median.
  • None of the 5 ancestors has a recall.
  • Of its descendants, K260419 (Hangzhou ChohoTech Co., Ltd., 2026) has gone furthest, with 0 descendants of its own.
  • 4 other devices also cite its predicate K180941.

How does its category compare?

All PNN devices

PNN Orthodontic Software: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.

FDA decisions per year · PNN

2in 2025

2016: 12017: 22018: 52019: 22020: 72021: 42022: 12023: 32024: 42025: 22026 (partial year): 6
2007high 7 (2020) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · PNN

177in 2024

2018: 229 days median2020: 221 days median2021: 58 days median2023: 90 days median2024: 177 days median2026 (partial year): 98 days median
2007high 229 (2018) · low 58 (2021)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · PNN

1in 2022

2021: 12022: 1
2007high 1 (2021) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · PNN

1in 2024

2024: 1
2007high 1 (2024) · low 0 (2007)2025

MAUDE reports naming product code PNN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20161—00
20172—00
2018522900
20192—00
2020722100
202145810
20221—10
202339000
2024417701
20252—00
20266980—

What is it indicated for?

RAYDENT SW is a software designed to assist dental professionals in planning patient treatment and designing treatment devices. The software performs simulations based on patient images, allowing reference to treatment plans, and is used as a tool to design treatment devices based on 3D mesh data. Treatment devices include prosthetic devices (Veneer, Crown, Bridge, In/Onlay) and orthodontic devices (Clear Aligner).

To use RAYDENT SW, users must have the necessary education and domain knowledge in orthodontic or prosthodontic practice and receive dedicated training in the use of the software.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K233625: Raydent SW.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K233625

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026