510(k) Report

510(k) · Cleared

Cleared

tmCMF Solution

K233874510(k) TraditionalCleared Jul 11, 2024217-day reviewClass II21 CFR 872.4760

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Techmah Cmf · JEY Plate, Bone

Cleared on Jul 11, 2024 as substantially equivalent to K231520 (Techmah Cmf, 2023) and 2 other predicates after a 217-day review. Its family tree reaches back 7 generations to 1993.

Decided
Jul 11, 2024
Review
217 days
Class
Class II
Product code
JEY
Recalls
None
Predicates
3

Its longest line of descent runs back 7 generations to K924630 (1993). 17 ancestors in all, the oldest K924810 (1993). No later device cites it as a predicate yet.

Other ancestors, by generation 1 generation back: 2 other ancestors2 generations back: 3 other ancestors4 generations back: 2 other ancestors5 generations back: 2 other ancestors6 generations back: 1 other ancestor K231520 · tmCMF Solution · Techmah Cmf · 2023K192282 · MedCAD® AccuPlan® System · Medcad · 2020K120956 · VSP System · Medical Modeling, Inc. · 2012K060950 · 3MATIC · Materialise NV · 2006K033849 · Simplant System · Materialise NV · 2004K970617 · CT-Modeller System · Materialise NV · 1997K924630 · Surgicad (TM) View (TM) · Surgicad Corp. · 1993−50
  1. Root · 7 generations backK924630 Surgicad (TM) View (TM)Surgicad Corp. · 1993
  2. 6 generations backK970617 CT-Modeller SystemMaterialise NV · 1997
  3. 5 generations backK033849 Simplant SystemMaterialise NV · 2004
  4. 4 generations backK060950 3MATICMaterialise NV · 2006
  5. 3 generations backK120956 VSP SystemMedical Modeling, Inc. · 2012
  6. 2 generations backK192282 MedCAD® AccuPlan® SystemMedcad · 2020
  7. 1 generation backK231520 tmCMF SolutionTechmah Cmf · 2023
  8. This deviceK233874 tmCMF SolutionTechmah Cmf · 2024
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K924630Surgicad (TM) View (TM)Surgicad Corp.1993—
−6K970617CT-Modeller SystemMaterialise NV1997—
−5K033849Simplant SystemMaterialise NV2004—
−4K0609503MATICMaterialise NV2006—
−3K120956VSP SystemMedical Modeling, Inc.2012—
−2K192282MedCAD® AccuPlan® SystemMedcad2020—
−1K231520tmCMF SolutionTechmah Cmf2023—
0 (this device)K233874tmCMF SolutionTechmah Cmf2024—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199310
200710
200830
200910
201010
201110
201710
201810
FIG. 1 — Lineage of K233874, 1993–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JEY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JEY device

  1. #1 K252246 Leforte MMF Systemscore 15.6 · 16 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K231520tmCMF Solution
Summary page 5
…21 CFR §872.4120 Product Code: JEY Subsequent Product Code: DZJ, LLZ III. LEGALLY MARKETED PREDICATE DEVICES Predicate Number: K231520 Predicate Trade Name: tmCMF Solution Product Code: DZJ & LLZ Use: Primary…
Techmah Cmf2023—
*K173039TruMatch CMF Titanium 3D Printed Implant
Summary page 6
…Page 1 of 21 TechMah CMF LLC K233874/S001 tmCMF Solution 510(k) Submission Predicate Number: K173039 Predicate Trade Name: TruMatch CMF Titanium 3D Printed Implant Product Code: JEY Use:…
Materialise NV2018—
*K170272TruMatch CMF Titanium 3D Printed Implant System
Summary page 6
…cate Trade Name: TruMatch CMF Titanium 3D Printed Implant Product Code: JEY Use: Secondary Predicate Predicate Number: K170272 Predicate Trade Name: TruMatch CMF Titanium 3D Printed Implant System Product Code: JEY Use:…
Materialise NV20172
†K063790The Synthes Matrixmandible Plate and Screw SystemSynthes (Usa)2007—
†K210731KLS Martin Individual Patient SolutionsKLS-Martin L.P.2022—
†K213684SurgiCase ViewerMaterialise NV2022—
†K080331Synthes Craniofacial Plate and Screw SystemSynthes (Usa)2008—
†K050608Synthes Carniofacial Plate and Screw SystemSynthes (Usa)20051
†K083388Synthes Matrixorthognathis Fixation SystemSynthes (Usa)20091

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 31 years and passes through 5 companies; a new generation was cleared every 4.0 years on median.
  • 3 of the 17 ancestors have a recall of any class.

How does its category compare?

All JEY devices

JEY Plate, Bone: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.

FDA decisions per year · JEY

2in 2025

2007: 92008: 72009: 42010: 62011: 52012: 102013: 82014: 62015: 72016: 12017: 52018: 72019: 62020: 62021: 42022: 52023: 22024: 52025: 22026 (partial year): 3
2007high 10 (2012) · low 1 (2016)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JEY

159in 2024

2007: 115 days median2008: 84 days median2009: 121 days median2010: 199 days median2011: 75 days median2012: 194 days median2013: 126 days median2014: 223 days median2015: 160 days median2017: 190 days median2018: 255 days median2019: 163 days median2020: 198 days median2021: 299 days median2022: 135 days median2024: 159 days median2026 (partial year): 258 days median
2007high 299 (2021) · low 75 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JEY

1in 2020

2008: 32009: 62010: 852013: 12020: 1
2007high 85 (2010) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JEY

1,003in 2025

2007: 292008: 242009: 932010: 2152011: 2412012: 4282013: 7662014: 6162015: 7672016: 5582017: 5682018: 6082019: 5952020: 6802021: 4512022: 3442023: 4952024: 6962025: 1,003
2007high 1,003 (2025) · low 24 (2008)2025

MAUDE reports naming product code JEY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20079115029
2008784324
20094121693
2010619985215
20115750241
2012101940428
201381261766
201462230616
201571600767
20161—0558
201751900568
201872550608
201961630595
202061981680
202142990451
202251350344
20232—0495
202451590696
20252—01,003
202632580—

What is it indicated for?

The tmCMF Solution is intended for use as a software system and image segmentation system for the transfer of imaging information from a medical scanner such as a CT-based system. The input data file is processed by the tmCMF Solution, and the result is an output data file that may then be provided as digital models or used as input to a manufacturing portion of the system that produces physical outputs, including anatomical models, surgical guides…

Read the full statement (160 words)

The tmCMF Solution is intended for use as a software system and image segmentation system for the transfer of imaging information from a medical scanner such as a CT-based system. The input data file is processed by the tmCMF Solution, and the result is an output data file that may then be provided as digital models or used as input to a manufacturing portion of the system that produces physical outputs, including anatomical models, surgical guides, dental splints, and implants for use in maxillofacial, midface, and mandibular surgery. Implants are intended for bone fixation and reconstruction, restoration of bone defects, and intended to provide continuity in regions where the bone is missing and/or to augment the bone by means of an onlay device in the maxillofacial skeleton, midface, mandible, and chin in adolescents (greater than 12 to 21 years of age) and adults. The tmCMF Solution is also intended as a preoperative software tool for simulating/evaluating virtual surgical treatment options.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K233874: tmCMF Solution.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K233874

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026