510(k) Report

510(k) · Cleared

Cleared

Access Ferritin

K234052510(k) TraditionalCleared Mar 20, 202490-day reviewClass II21 CFR 866.5340

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Beckman Coulter, Inc. · JMG Radioimmunoassay (Two-Site Solid Phase), Ferritin

Cleared on Mar 20, 2024 as substantially equivalent to K926221 (Bio-Rad Laboratories, Inc., 1993) and 1 other predicate after a 90-day review. Its family tree reaches back 2 generations to 1993.

Decided
Mar 20, 2024
Review
90 days
Class
Class II
Product code
JMG
Recalls
None
Predicates
2

Its longest line of descent runs back 2 generations to K926221 (1993). No later device cites it as a predicate yet.

  1. Root · 2 generations backK926221 Access Ferritin AssayBio-Rad Laboratories, Inc. · 1993 · Recalled
  2. 1 generation backK052082 Ferritin on the Access Immunoassay Systems, Model 33020Beckman Coulter, Inc. · 2005 · Recalled
  3. This deviceK234052 Access FerritinBeckman Coulter, Inc. · 2024
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K926221Access Ferritin AssayBio-Rad Laboratories, Inc.19931
−1K052082Ferritin on the Access Immunoassay Systems, Model 33020Beckman Coulter, Inc.20051
0 (this device)K234052Access FerritinBeckman Coulter, Inc.2024—
FIG. 1 — Lineage of K234052, 1993–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JMG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K926221Access Ferritin Assay
Summary page 4
…Name: Access Ferritin Common Name: Ferritin Classification Regulation: 21 CFR 866.5340 Classification Product Code: JMG Predicate Device: Access Ferritin 510(k) Number K926221, k052082 Device Description The Access Ferritin assay is a sandwich immunoenzymatic assay. The Access Ferritin assay consists o…
Bio-Rad Laboratories, Inc.19931
*K052082Ferritin on the Access Immunoassay Systems, Model 33020
Summary page 4
…cess Ferritin Common Name: Ferritin Classification Regulation: 21 CFR 866.5340 Classification Product Code: JMG Predicate Device: Access Ferritin 510(k) Number K926221, k052082 Device Description The Access Ferritin assay is a sandwich immunoenzymatic assay. The Access Ferritin assay consists of the rea…
Beckman Coulter, Inc.20051

Also cleared against K926221: 4 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 31 years and passes through 2 companies; a new generation was cleared every 18.6 years on median.
  • 2 of the 2 ancestors have a recall of any class.
  • 4 other devices also cite its predicate K926221.

How does its category compare?

All JMG devices

JMG Radioimmunoassay (Two-Site Solid Phase), Ferritin: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.

FDA decisions per year · JMG

1in 2024

2024: 1
2007high 1 (2024) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JMG

Too few JMG 510(k)s in any year since 2007 to give a median.

Recalls per year · JMG

1in 2025

2013: 12025: 1
2007high 1 (2013) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JMG

12in 2025

2010: 12013: 122014: 22016: 12017: 12018: 32019: 12020: 42021: 52022: 22023: 132024: 112025: 12
2007high 13 (2023) · low 0 (2007)2025

MAUDE reports naming product code JMG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—01
20110—00
20120—00
20130—112
20140—02
20150—00
20160—01
20170—01
20180—03
20190—01
20200—04
20210—05
20220—02
20230—013
20241—011
20250—112
20260—0—

What is it indicated for?

The Access Ferritin assay is a paramagnetic particle, chemiluminescent immunoassay for the quantitative determination of ferritin levels in human serum and plasma (heparin) using the Access Immunoassay Systems.

Ferritin is used as an aid in the diagnosis of iron deficiency or iron overload.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K234052: Access Ferritin.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K234052

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026