510(k) · Cleared
ClearedAffinity Fusion Oxygenator with Integrated Arterial Filter and Balance Biosurface (BB811); Affinity Fusion Oxygenator with Integrated Arterial Filter and Cardiotomy/Venous Reservoir with Balance Biosurface (BB841); Affinity Fusion Oxygenator with Integrated Arterial Filter and Balance Biosurface NON STERILE (BB811-NS)
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Medtronic Perfusion Systems · DTZ Oxygenator, Cardiopulmonary Bypass
Cleared on Jul 10, 2024 as substantially equivalent to K230640 (Medtronic, Inc., 2023) after a 124-day review. Its family tree reaches back 3 generations to 2019. 1 of the 5 devices in its family, counting itself, has a Class I recall.
- Decided
- Jul 10, 2024
- Review
- 124 days
- Class
- Class II
- Product code
- DTZ
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 3 generations to K183511 (2019). 4 ancestors in all. No later device cites it as a predicate yet. 1 of the 5 devices in this family, counting this one, has a Class I recall.
- Root · 3 generations backK183511 Affinity Pixie™ Oxygenator with Balance™ Biosurface (Model BBP211)…Medtronic, Inc. · 2019 · Recalled (Class I)
- 2 generations backK203111 Affinity Fusion Oxygenator System, Affinity Pixie Oxygenation SystemMedtronic · 2021 · Recalled
- 1 generation backK230640 Affinity Fusion™ Oxygenator SystemMedtronic, Inc. · 2023
- This deviceK240666 Affinity Fusion Oxygenator with Integrated Arterial Filter and…Medtronic Perfusion Systems · 2024
Class I recalls in this family
- K183511 Affinity Pixie™ Oxygenator with Balance™…3 generations back · 2019
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −3 | K183511 | Affinity Pixie™ Oxygenator with Balance™ Biosurface (Model BBP211), Affinity… | Medtronic, Inc. | 2019 | Class I |
| −2 | K203111 | Affinity Fusion Oxygenator System, Affinity Pixie Oxygenation System | Medtronic | 2021 | 6 |
| −1 | K230640 | Affinity Fusion™ Oxygenator System | Medtronic, Inc. | 2023 | — |
| 0 (this device) | K240666 | Affinity Fusion Oxygenator with Integrated Arterial Filter and Balance… | Medtronic Perfusion Systems | 2024 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2019 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DTZ device
- #1 K240934 Quantum Perfusion Blood Oxygenator ECC…score 14.3 · 12 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K230640 | Affinity Fusion™ Oxygenator SystemSummary page 7…Affinity Fusion TM Oxygenator with Integrated Arterial Filter and Balance TM Biosurface (Non-Sterile) (B811-NS) 510(k) K230640 Concurrence Date April 6, 2023 12.3 Device Description The Affinity Fusion Oxygenator with Integrated Arterial… | 2023 |
| † | K191077 | Affinity CP Centrifugal Blood Pump, Affinity CP Centrifugal Blood Pump with Balance… | 2019 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (1 Class I)
No FDA recall names this device.
Relatives with a Class I recall
Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.
- K183511Affinity Pixie™ Oxygenator with Balance™ Biosurface (Model BBP211), Affinity Pixie™ Oxygenator and…Medtronic, Inc. · 2019 · 3 generations back · ◆ on the line of descent in FIG. 110 Class I recalls
What does this lineage say?
- The line of descent spans 5 years and passes through 3 companies; a new generation was cleared every 1.6 years on median.
- 2 of the 4 ancestors have a recall of any class; 1 has a Class I recall.
How does its category compare?
All DTZ devicesDTZ Oxygenator, Cardiopulmonary Bypass: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.
FDA decisions per year · DTZ
2in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DTZ
124in 2024
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DTZ
1in 2025
Class I (3 since 2007) Class II/III not classified
Adverse event reports per year · DTZ
976in 2025
MAUDE reports naming product code DTZ, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 4 | 55 | 7 | 134 |
| 2008 | 3 | 88 | 5 | 105 |
| 2009 | 9 | 210 | 0 | 52 |
| 2010 | 2 | — | 1 | 119 |
| 2011 | 4 | 160 | 13 | 190 |
| 2012 | 9 | 90 | 14 | 215 |
| 2013 | 9 | 28 | 0 | 346 |
| 2014 | 5 | 28 | 2 | 764 |
| 2015 | 9 | 134 | 0 | 658 |
| 2016 | 3 | 62 | 1 | 443 |
| 2017 | 2 | — | 0 | 388 |
| 2018 | 3 | 72 | 2 (2) | 320 |
| 2019 | 5 | 90 | 1 | 489 |
| 2020 | 5 | 93 | 3 | 442 |
| 2021 | 5 | 336 | 1 (1) | 595 |
| 2022 | 2 | — | 6 | 559 |
| 2023 | 5 | 145 | 0 | 738 |
| 2024 | 3 | 124 | 0 | 535 |
| 2025 | 2 | — | 1 | 976 |
| 2026 | 3 | 137 | 0 | — |
What is it indicated for?
The Affinity Fusion Oxygenator with Integrated Arterial Filter and Balance Biosurface is intended to be used in an extracorporeal perfusion circuit to oxygenate and remove carbon dioxide from the blood and to cool or warm the blood during routine cardiopulmonary bypass procedures up to 6 hours in duration. The Affinity Fusion Oxygenator with Integrated Arterial Filter and Balance Biosurface is designed to filter from the circuit microemboli larger than…
Read the full statement (252 words)
The Affinity Fusion Oxygenator with Integrated Arterial Filter and Balance Biosurface is intended to be used in an extracorporeal perfusion circuit to oxygenate and remove carbon dioxide from the blood and to cool or warm the blood during routine cardiopulmonary bypass procedures up to 6 hours in duration.
The Affinity Fusion Oxygenator with Integrated Arterial Filter and Balance Biosurface is designed to filter from the circuit microemboli larger than the specified micron size for periods up to six hours during cardiopulmonary bypass surgery.
The Affinity Fusion Oxygenator with Integrated Arterial Filter and Balance Biosurface is intended to be used in an extracorporeal perfusion circuit to oxygenate and remove carbon dioxide from the blood and to cool or warm the blood during routine cardiopulmonary bypass procedures up to 6 hours in duration.
The Affinity Fusion Oxygenator with Integrated Arterial Filter and Balance Biosurface is designed to filter from the circuit microemboli larger than the specified micron size for periods up to six hours during cardiopulmonary bypass surgery.
The Affinity Fusion CardiotomyNenous Reservoir with Balance Biosurface is intended to be used in an extracorporeal perfusion circuit to collect venous and cardiotomy suctioned blood during routine cardiopulmonary procedures up to 6 hours in duration. The CVR is also intended for use during vacuum assisted venous drainage (VAVD) procedures.
The Affinity Fusion CardiotomyNenous Reservoir with Balance Biosurface is also intended for use after open heart surgery to collect autologous blood from the chest and to aseptically return the blood to the patient for blood volume replacement
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K240666 · printed Nov 6, 2026
Cite this page
510(k) Report. “K240666: Affinity Fusion Oxygenator with Integrated Arterial Filter and Balance Biosurface (BB811); Affinity Fusion Oxygenator with Integrated Arterial Filter and Cardiotomy/Venous Reservoir with Balance Biosurface (BB841); Affinity Fusion Oxygenator with Integrated Arterial Filter and Balance Biosurface NON STERILE (BB811-NS).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K240666
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026