510(k) · Cleared
ClearedRespiratory Muscle Trainer
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Chongqing Moffy Innovation Technology Co., Ltd. · BYI Percussor, Powered-Electric
Cleared on Dec 18, 2024 after a 254-day review. FDA’s file for it is a 510(k) statement, which names no predicate.
- Decided
- Dec 18, 2024
- Review
- 254 days
- Class
- Class II
- Product code
- BYI
- Recalls
- None
- Predicates
- 0
FDA’s file for it is a 510(k) statement, which names no predicate.
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in BYI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new BYI device
- #1 K252849 AffloVest® Mobile Airway Clearance Therapyscore 12.5 · 5 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All BYI devicesBYI Percussor, Powered-Electric: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.
FDA decisions per year · BYI
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · BYI
157in 2024
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · BYI
1in 2017
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · BYI
38in 2025
MAUDE reports naming product code BYI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 1 | — | 0 | 8 |
| 2008 | 0 | — | 0 | 5 |
| 2009 | 0 | — | 0 | 8 |
| 2010 | 1 | — | 0 | 7 |
| 2011 | 1 | — | 0 | 17 |
| 2012 | 1 | — | 0 | 8 |
| 2013 | 3 | 225 | 0 | 6 |
| 2014 | 0 | — | 1 | 10 |
| 2015 | 1 | — | 0 | 4 |
| 2016 | 0 | — | 0 | 4 |
| 2017 | 1 | — | 1 | 4 |
| 2018 | 1 | — | 0 | 9 |
| 2019 | 0 | — | 0 | 6 |
| 2020 | 0 | — | 0 | 4 |
| 2021 | 2 | — | 0 | 15 |
| 2022 | 1 | — | 0 | 16 |
| 2023 | 0 | — | 0 | 9 |
| 2024 | 3 | 157 | 0 | 19 |
| 2025 | 1 | — | 0 | 38 |
| 2026 | 1 | — | 0 | — |
What is it indicated for?
Respiratory Muscle Trainer is indicated for use as a Positive Expiratory Pressure (PEP) Device for improving the clearance of mucus secretions from the airways. Respiratory Muscle Trainer vibrates the airway walls to assist in loosening mucus and intermittently increases endobronchial pressure so that the airway patency can be maintained during exhalation, reducing the potential of mucus becoming trapped as it moves up the airways.
The device may also be useful in the removal of mucus from patients who have chronic bronchitis or bronchiectasis and in conjunction with a medical need for positive expiratory pressure (PEP) therapy.
Indications for use as stated in the FDA 510(k) statement.
https://510kreport.com/device/K240959 · printed Nov 6, 2026
Cite this page
510(k) Report. “K240959: Respiratory Muscle Trainer.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K240959
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026