M6-C™ Single Use, Disposable Instrumentation

K241117510(k) TraditionalCleared Jun 21, 202459-day reviewClass II21 CFR 888.4515

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Spinal Kinetics / Orthofix / Seaspine · QLQ Manual Instruments Designed For Use With Total Disc Replacement Devices

Cleared on Jun 21, 2024 as substantially equivalent to K220861 (Spinal Kinetics, LLC, 2022) after a 59-day review. Its family tree reaches back 3 generations to 2020.

Decided
Jun 21, 2024
Review
59 days
Class
Class II
Product code
QLQ
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to P200022 (2020). No later device cites it as a predicate yet.

  1. Root · 3 generations backP200022 Simplify® Cervical Artificial DiscNuvasive, Inc. · 2020 · Recalled
  2. 2 generations backK211757 Simplify DiscNuvasive, Inc. · 2021
  3. 1 generation backK220861 M6-C Artificial Cervical Disc Instruments ASSpinal Kinetics, LLC · 2022
  4. This deviceK241117 M6-C™ Single Use, Disposable InstrumentationSpinal Kinetics / Orthofix / Seaspine · 2024
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3P200022Simplify® Cervical Artificial DiscNuvasive, Inc.20201
−2K211757Simplify DiscNuvasive, Inc.2021—
−1K220861M6-C Artificial Cervical Disc Instruments ASSpinal Kinetics, LLC2022—
0 (this device)K241117M6-C™ Single Use, Disposable InstrumentationSpinal Kinetics / Orthofix / Seaspine2024—
FIG. 1 — Lineage of K241117, 2020–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in QLQ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new QLQ device

  1. #1 K221848 prodisc C SK, prodisc C Nova, and prodisc C…score 12.9 · 1 generation · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K220861M6-C Artificial Cervical Disc Instruments AS
Summary page 4
…me: Orthopedic manual surgical instrumentation for use with total disc replacement devices Primary Predicate: K220861 - M6-C Artificial Cervical Disc Instruments AS Reason for the 510(k) Submission: To introduce a single-use version of the exist…
Spinal Kinetics, LLC2022—

Also cleared against K220861: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 4 years and passes through 3 companies; a new generation was cleared every 11 months on median.
  • 1 of the 3 ancestors has a recall of any class.
  • 1 other device also cites its predicate K220861.

How does its category compare?

All QLQ devices

QLQ Manual Instruments Designed For Use With Total Disc Replacement Devices: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.

FDA decisions per year · QLQ

3so far in 2026, the most since 2007

2021: 12022: 22023: 12024: 22025: 12026 (partial year): 3
2007high 3 (2026) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · QLQ

28in 2026

2026 (partial year): 28 days median
2007high 28 (2026)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · QLQ

No recall names QLQ since 2007.

Adverse event reports per year · QLQ

2in 2022

2021: 12022: 2
2007high 2 (2022) · low 0 (2007)2025

MAUDE reports naming product code QLQ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—00
20190—00
20200—00
20211—01
20222—02
20231—00
20242—00
20251—00
20263280—

What is it indicated for?

The M6-C™ Single Use, Disposable Instrumentation are intended for the placement and positioning of the M6-C Artificial Cervical Disc.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K241117: M6-C™ Single Use, Disposable Instrumentation.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K241117

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026