510(k) · Cleared
ClearedLifeScale Gram Negative Kit (LSGN) with the LifeScale AST system
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Affinity Biosensors, LLC · SAN Automated Antimicrobial Susceptibility Test System For Positive Blood Culture Samples
Cleared on Oct 23, 2024 as substantially equivalent to K211815 (Affinity Biosensors, 2024) after a 166-day review. Its family tree reaches back 3 generations to 2017. 1 later device descends from it.
- Decided
- Oct 23, 2024
- Review
- 166 days
- Class
- Class II
- Product code
- SAN
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 3 generations to DEN160032 (2017). 1 later device descends from it, 1 citing it directly.
- Root · 3 generations backDEN160032 Accelerate Pheno system, Accelerate Phenotest BC KitAccelerate Diagnotics · 2017
- 2 generations backK192665 Accelerate Pheno System, Accelerate PhenoTest BC KitAccelerate Diagnostics, Inc. · 2020 · Recalled
- 1 generation backK211815 LifeScale Gram Negative Kit (LSGN) with the LifeScale AST SystemAffinity Biosensors · 2024
- This deviceK241324 LifeScale Gram Negative Kit (LSGN) with the LifeScale AST systemAffinity Biosensors, LLC · 2024
- Descendant · cites it directly · 0 of its ownK251875 LifeScale Gram Negative Kit (LSGN) with the LifeScale AST systemAffinity Biosensors, LLC · 2025
Most influential descendants
Showing 1 of 1 · See all- K251875LifeScale Gram Negative Kit (LSGN) with the LifeScale AST systemAffinity Biosensors, LLC · 2025 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −3 | DEN160032 | Accelerate Pheno system, Accelerate Phenotest BC Kit | Accelerate Diagnotics | 2017 | — |
| −2 | K192665 | Accelerate Pheno System, Accelerate PhenoTest BC Kit | Accelerate Diagnostics, Inc. | 2020 | 2 |
| −1 | K211815 | LifeScale Gram Negative Kit (LSGN) with the LifeScale AST System | Affinity Biosensors | 2024 | — |
| 0 (this device) | K241324 | LifeScale Gram Negative Kit (LSGN) with the LifeScale AST system | Affinity Biosensors, LLC | 2024 | — |
| +1 | K251875 | LifeScale Gram Negative Kit (LSGN) with the LifeScale AST system | Affinity Biosensors, LLC | 2025 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2025 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in SAN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new SAN device
- #1 K211815 LifeScale Gram Negative Kit (LSGN) with the…score 13.4 · 2 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K211815 | LifeScale Gram Negative Kit (LSGN) with the LifeScale AST SystemSummary page 6…g Regulation Number: 21 CFR 866.1650 Regulatory Class: Class II Product Code: SAN, LON Predicate Device: K211815 LifeScaleTM Gram Negative Kit (LSGN) with the LifeScale AST system Purpose for Submission: i. To obtain a substantial equivalenc… | 2024 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K251875 | LifeScale Gram Negative Kit (LSGN) with the LifeScale AST system | 2025 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 7 years and passes through 4 companies; a new generation was cleared every 3.5 years on median.
- 1 of the 3 ancestors has a recall of any class.
- Of its descendants, K251875 (Affinity Biosensors, LLC, 2025) has gone furthest, with 0 descendants of its own.
- 1 other device also cites its predicate K211815.
How does its category compare?
All SAN devicesSAN Automated Antimicrobial Susceptibility Test System For Positive Blood Culture Samples: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.
FDA decisions per year · SAN
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · SAN
577in 2024
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · SAN
No recall names SAN since 2007.
Adverse event reports per year · SAN
No MAUDE report names SAN since 2007.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 0 |
| 2011 | 0 | — | 0 | 0 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 0 | — | 0 | 0 |
| 2014 | 0 | — | 0 | 0 |
| 2015 | 0 | — | 0 | 0 |
| 2016 | 0 | — | 0 | 0 |
| 2017 | 0 | — | 0 | 0 |
| 2018 | 0 | — | 0 | 0 |
| 2019 | 0 | — | 0 | 0 |
| 2020 | 0 | — | 0 | 0 |
| 2021 | 0 | — | 0 | 0 |
| 2022 | 0 | — | 0 | 0 |
| 2023 | 0 | — | 0 | 0 |
| 2024 | 4 | 577 | 0 | 0 |
| 2025 | 1 | — | 0 | 0 |
| 2026 | 3 | 169 | 0 | — |
What is it indicated for?
The LifeScale AST system is a multiplexed in vitro diagnostic test that uses a microfluidic sensor and resonant frequency to calculate organism concentration and/or mass distribution for quantitative antimicrobial susceptibility testing (AST). Testing is performed directly on blood cultures signaled as positive by a continuous monitoring blood culture system and confirmed by Gram stain. The LifeScale AST system does not provide organism identification…
Read the full statement (355 words)
The LifeScale AST system is a multiplexed in vitro diagnostic test that uses a microfluidic sensor and resonant frequency to calculate organism concentration and/or mass distribution for quantitative antimicrobial susceptibility testing (AST). Testing is performed directly on blood cultures signaled as positive by a continuous monitoring blood culture system and confirmed by Gram stain. The LifeScale AST system does not provide organism identification and is not indicated for use with polymicrobial samples. Interpretive results (Susceptible/Intermediate/Susceptible-dose dependent/Resistant) are provided for specific drug/organism combinations. Results are intended to be used in conjunction with other clinical and laboratory findings. Standard laboratory protocols for processing positive blood cultures should be followed to ensure availability of isolates for supplemental testing as needed. Additionally, subculture of positive blood culture is necessary for the susceptibility testing of organisms present in polymicrobial samples, for testing antimicrobial agents and species not indicated for testing with the device and for epidemiologic testing and for recovery of organisms present in microbial samples.
The LifeScale AST System and the LifeScale Gram-negative Panel (LSGN) are indicated for testing of positive blood culture samples confirmed by Gram stain as containing Gram-negative organisms for the following antimicrobial agents and specific target organisms identified below:
• Amikacin: Acinetobacter spp., Escherichia coli, Klebsiella pneumoniae, Klebsiella aerogenes, Klebsiella oxytoca, Klebsiella variicola, Pseudomonas aeruginosa
• Ampicillin: Escherichia coli
• Aztreonam: Escherichia coli, Klebsiella pneumoniae, Klebsiella aerogenes, Klebsiella oxytoca
• Cefazolin: Escherichia coli, Klebsiella pneumoniae, Klebsiella variicola
• Cefepime: Escherichia coli, Klebsiella pneumoniae, Klebsiella aerogenes, Klebsiella oxytoca, Pseudomonas aeruginosa
• Ceftazidime: Acinetobacter spp. (other than Acinetobacter ursingii), Escherichia coli, Klebsiella aerogenes, Klebsiella oxytoca, Klebsiella variicola, Klebsiella pneumoniae, Pseudomonas aeruginosa
• Ceftazidime-avibactam: Escherichia coli, Klebsiella aerogenes, Klebsiella oxytoca
• Ertapenem: Escherichia coli, Klebsiella aerogenes, Klebsiella pneumoniae, Klebsiella oxytoca
• Gentamicin: Escherichia coli, Klebsiella pneumoniae, Klebsiella aerogenes, Klebsiella oxytoca, Klebsiella variicola, Pseudomonas aeruginosa
• Levofloxacin: Escherichia coli, Klebsiella pneumoniae, Klebsiella aerogenes, Klebsiella oxytoca, Pseudomonas aeruginosa
• Meropenem: Acinetobacter spp., Escherichia coli, Klebsiella pneumoniae, Klebsiella oxytoca, Pseudomonas aeruginosa
• Meropenem-vaborbactam: Escherichia coli, Klebsiella pneumoniae, Klebsiella aerogenes, Klebsiella oxytoca
• Piperacillin-tazobactam: Acinetobacter spp., Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa
• Trimethoprim-sulfamethoxazole: Escherichia coli, Klebsiella aerogenes, Klebsiella oxytoca, Klebsiella variicola
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K241324 · printed Nov 6, 2026
Cite this page
510(k) Report. “K241324: LifeScale Gram Negative Kit (LSGN) with the LifeScale AST system.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K241324
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026