Shenzhen Nuon Medical Equipment Co., Ltd. · OAP Laser, Comb, Hair

Cleared on Nov 8, 2024 as substantially equivalent to K230597 (Light Tree Ventures Europe B.V., 2023) and 2 other predicates after a 179-day review. Its family tree reaches back 11 generations to 2000.

Decided
Nov 8, 2024
Review
179 days
Class
Class II
Product code
OAP
Recalls
None
Predicates
3

Its longest line of descent runs back 11 generations to K001179 (2000). 30 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 11 generations backK001179 Super Nova, AcubeamLight Force Therapy, Inc. · 2000
  2. 7 generations between
  3. 3 generations backK173729 Revian RedPhotonmd, Inc. · 2018
  4. 2 generations backK211038 Biophotas Celluma RESTOREBiophotas, Inc. · 2021
  5. 1 generation backK230597 Aduro Comb (Model: SZ-22, SZ-22A, SZ-22B)Light Tree Ventures Europe B.V. · 2023
  6. This deviceK241342 Hair Growth Comb (SZ-23,SZ-23A)Shenzhen Nuon Medical Equipment Co., Ltd. · 2024
Show all 11 generations
  1. Root · 11 generations backK001179 Super Nova, AcubeamLight Force Therapy, Inc. · 2000
  2. 10 generations backK020017 Medx 1000 SeriesMedx Electronics, Inc. · 2002
  3. 9 generations backK032816 Quantum Light Therapy SystemStargate International, Inc. · 2004
  4. 8 generations backK091496 Mep-90 Hair Growth Stimulation SystemMidwest Rf, LLC · 2010
  5. 7 generations backK113097 Laser HelmetTheradome, Inc. · 2012
  6. 6 generations backK150613 LaserCap LC Pro and LC EliteTransdermal Cap, Inc. · 2015
  7. 5 generations backK153618 Capillus202Capillus, LLC · 2016
  8. 4 generations backK162782 iHelmet Hair Growth SystemSlinph Technologies Co., Ltd. · 2017
  9. 3 generations backK173729 Revian RedPhotonmd, Inc. · 2018
  10. 2 generations backK211038 Biophotas Celluma RESTOREBiophotas, Inc. · 2021
  11. 1 generation backK230597 Aduro Comb (Model: SZ-22, SZ-22A, SZ-22B)Light Tree Ventures Europe B.V. · 2023
  12. This deviceK241342 Hair Growth Comb (SZ-23,SZ-23A)Shenzhen Nuon Medical Equipment Co., Ltd. · 2024
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−11K001179Super Nova, AcubeamLight Force Therapy, Inc.2000—
−10K020017Medx 1000 SeriesMedx Electronics, Inc.2002—
−9K032816Quantum Light Therapy SystemStargate International, Inc.2004—
−8K091496Mep-90 Hair Growth Stimulation SystemMidwest Rf, LLC2010—
−7K113097Laser HelmetTheradome, Inc.2012—
−6K150613LaserCap LC Pro and LC EliteTransdermal Cap, Inc.2015—
−5K153618Capillus202Capillus, LLC2016—
−4K162782iHelmet Hair Growth SystemSlinph Technologies Co., Ltd.2017—
−3K173729Revian RedPhotonmd, Inc.2018—
−2K211038Biophotas Celluma RESTOREBiophotas, Inc.2021—
−1K230597Aduro Comb (Model: SZ-22, SZ-22A, SZ-22B)Light Tree Ventures Europe B.V.2023—
0 (this device)K241342Hair Growth Comb (SZ-23,SZ-23A)Shenzhen Nuon Medical Equipment Co., Ltd.2024—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200210
200710
200910
201120
201210
201310
201430
201520
201620
201720
202010
202110
202210
FIG. 1 — Lineage of K241342, 2000–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OAP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OAP device

  1. #1 K222790 F65 Laser Systemscore 20.5 · 21 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K230597Aduro Comb (Model: SZ-22, SZ-22A, SZ-22B)
Our reading of the summary gave K230579, FDA’s number for Smart Wedge algorithm (Edwards Lifesciences, LLC). Corrected to the number with two digits swapped whose FDA name carries the summary’s words for the device, “Aduro Comb”.
Light Tree Ventures Europe B.V.2023—
*K211038Biophotas Celluma RESTORE
Summary page 5
…omb, Hair 510(k) Number: K230579 Review Panel: General & Plastic Surgery Product Code: OAP Regulation Number: 21 CFR 890.5500 Regulation Class: II 3.2 Predicate Device (K211038) Sponsor: Biophotas Inc Trade Name: Biophotas Celluma RESTORE Classification Name: Laser, Comb, Hair 510(k) Number: K211038 Revie…
Biophotas, Inc.2021—
*K222477Hair Growth Device
Summary page 6
…Number: K211038 Review Panel: General & Plastic Surgery Product Code: OAP Regulation Number: 21 CFR 890.5500 Regulation Class: II 3.3 Predicate Device 3 (K222477) Sponsor: Dongguan Lescolton Medical Equipment Co., Ltd Trade Name: Hair Growth Device Classification Name: Laser, Comb, Hair 510…
Dongguan Lescolton Medical Equipment Co., Ltd.2022—

Also cleared against K230597: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 24 years and passes through 12 companies; a new generation was cleared every 1.7 years on median.
  • None of the 30 ancestors has a recall.
  • 1 other device also cites its predicate K230597.

How does its category compare?

All OAP devices

OAP Laser, Comb, Hair: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.

FDA decisions per year · OAP

6in 2025

2007: 12009: 12010: 12011: 42012: 22013: 32014: 32015: 82016: 82017: 52018: 152019: 92020: 92021: 52022: 82023: 82024: 102025: 62026 (partial year): 9
2007high 15 (2018) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OAP

87in 2025

2011: 89 days median2013: 262 days median2014: 80 days median2015: 126 days median2016: 83 days median2017: 83 days median2018: 87 days median2019: 89 days median2020: 88 days median2021: 89 days median2022: 99 days median2023: 81 days median2024: 94 days median2025: 87 days median2026 (partial year): 83 days median
2007high 262 (2013) · low 80 (2014)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · OAP

No recall names OAP since 2007.

Adverse event reports per year · OAP

11in 2025

2011: 12013: 12015: 22016: 12017: 12018: 12019: 42021: 32022: 22024: 12025: 11
2007high 11 (2025) · low 0 (2007)2025

MAUDE reports naming product code OAP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20080—00
20091—00
20101—00
201148901
20122—00
2013326201
201438000
2015812602
201688301
201758301
2018158701
201998904
202098800
202158903
202289902
202388100
2024109401
2025687011
20269830—

What is it indicated for?

The Hair Growth Comb (Model: SZ-23 ,SZ-23A,) is indicated to treat Androgenetic Alopecia and promote hair growth in males who have Norwood- Hamilton Classifications of Ila - V patterns of hair loss and to treat Androgenetic Alopecia and promote hair growth in females who have Ludwig-Savin Scale 1-1 to 1-4, 11-1, 11-2 or frontal patterns of hair loss; both with Fitzpatrick Skin Types I - IV.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K241342: Hair Growth Comb (SZ-23,SZ-23A).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K241342

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026