510(k) Report

510(k) · Cleared

Cleared

BTL-398

K241516510(k) TraditionalCleared Feb 10, 2025257-day reviewClass II21 CFR 876.5320

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

BTL Industries, Inc. · KPI Stimulator, Electrical, Non-Implantable, For Incontinence

Cleared on Feb 10, 2025 as substantially equivalent to K181497 (BTL Industries, Inc., 2018) after a 257-day review. Its family tree reaches back 10 generations to 1995.

Decided
Feb 10, 2025
Review
257 days
Class
Class II
Product code
KPI
Recalls
None
Predicates
1

Its longest line of descent runs back 10 generations to K930530 (1995). 36 ancestors in all, the oldest K813008 (1981). No later device cites it as a predicate yet.

  1. Root · 10 generations backK930530 Incare PRS 9300 Pelvic FL Thera Syst/Treat Uri IncHollister, Inc. · 1995
  2. 6 generations between
  3. 3 generations backK110179 IncontrolIncontrol Medical, LLC · 2012
  4. 2 generations backK134020 IntonemvIncontrol Medical, LLC · 2014
  5. 1 generation backK181497 HPM-6000UFBTL Industries, Inc. · 2018
  6. This deviceK241516 BTL-398BTL Industries, Inc. · 2025
Show all 10 generations
  1. Root · 10 generations backK930530 Incare PRS 9300 Pelvic FL Thera Syst/Treat Uri IncHollister, Inc. · 1995
  2. 9 generations backK961872 Incare Pelvic Floor Therapy System with Desktop ComputerHollister, Inc. · 1996
  3. 8 generations backK974048 Incare Pelvic Floor Therapy System with Desktop ComputerHollister, Inc. · 1997
  4. 7 generations backK013612 Incare Pelvic Floor Therapy SystemHollister, Inc. · 2002
  5. 6 generations backK050483 Evadri Bladder Control SystemsHollister, Inc. · 2005
  6. 5 generations backK053434 Myotrac Infiniti Electrical StimulatorThought Technology, Ltd. · 2006
  7. 4 generations backK080950 Stiwell MED4Otto Bock, Austria GmbH · 2009
  8. 3 generations backK110179 IncontrolIncontrol Medical, LLC · 2012
  9. 2 generations backK134020 IntonemvIncontrol Medical, LLC · 2014
  10. 1 generation backK181497 HPM-6000UFBTL Industries, Inc. · 2018
  11. This deviceK241516 BTL-398BTL Industries, Inc. · 2025
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−10K930530Incare PRS 9300 Pelvic FL Thera Syst/Treat Uri IncHollister, Inc.1995—
−9K961872Incare Pelvic Floor Therapy System with Desktop ComputerHollister, Inc.1996—
−8K974048Incare Pelvic Floor Therapy System with Desktop ComputerHollister, Inc.1997—
−7K013612Incare Pelvic Floor Therapy SystemHollister, Inc.2002—
−6K050483Evadri Bladder Control SystemsHollister, Inc.2005—
−5K053434Myotrac Infiniti Electrical StimulatorThought Technology, Ltd.2006—
−4K080950Stiwell MED4Otto Bock, Austria GmbH2009—
−3K110179IncontrolIncontrol Medical, LLC2012—
−2K134020IntonemvIncontrol Medical, LLC2014—
−1K181497HPM-6000UFBTL Industries, Inc.2018—
0 (this device)K241516BTL-398BTL Industries, Inc.2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198110
198610
198710
198910
199110
199410
199520
199630
199720
199820
200020
200130
200330
200420
201610
FIG. 1 — Lineage of K241516, 1995–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KPI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KPI device

  1. #1 K262353 BTL-299-Fscore 14.8 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K181497HPM-6000UF
Summary page 6
…K241516 Page 2 of 5 3. Predicate Device Identification K181497 HPM-6000UF BTL Industries, Inc. The predicate device was never subjected to a design related recall. 4. Device Description The…
BTL Industries, Inc.2018—

Also cleared against K181497: 5 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 30 years and passes through 5 companies; a new generation was cleared every 3.0 years on median.
  • None of the 36 ancestors has a recall.
  • 5 other devices also cite its predicate K181497.

How does its category compare?

All KPI devices

KPI Stimulator, Electrical, Non-Implantable, For Incontinence: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.

FDA decisions per year · KPI

7so far in 2026, the most since 2007

2007: 12008: 12009: 22011: 12012: 22013: 12014: 32015: 62016: 32017: 12018: 32019: 22020: 12021: 32022: 32023: 32024: 42025: 42026 (partial year): 7
2007high 7 (2026) · low 0 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KPI

263in 2025

2014: 57 days median2015: 260 days median2016: 89 days median2018: 304 days median2021: 217 days median2022: 181 days median2023: 197 days median2024: 172 days median2025: 263 days median2026 (partial year): 248 days median
2007high 304 (2018) · low 57 (2014)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KPI

No recall names KPI since 2007.

Adverse event reports per year · KPI

2in 2024

2013: 12015: 22017: 42019: 22020: 32021: 12022: 22023: 62024: 2
2007high 6 (2023) · low 0 (2007)2025

MAUDE reports naming product code KPI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20081—00
20092—00
20100—00
20111—00
20122—00
20131—01
201435700
2015626002
201638900
20171—04
2018330400
20192—02
20201—03
2021321701
2022318102
2023319706
2024417202
2025426300
202672480—

What is it indicated for?

The device is intended to provide entirely non-invasive electromagnetic stimulation of pelvic floor musculature for the purpose of rehabilitation of weak pelvic muscles and restoration of neuromuscular control for the treatment of male and female urinary incontinence.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K241516: BTL-398.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K241516

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026