Imbio, Inc. · QIH Automated Radiological Image Processing Software

Cleared on Aug 30, 2024 as substantially equivalent to K203256 (Imbio, LLC, 2021) after a 65-day review. Its family tree reaches back 8 generations to 1995.

Decided
Aug 30, 2024
Review
65 days
Class
Class II
Product code
QIH
Recalls
None
Predicates
1

Its longest line of descent runs back 8 generations to K945512 (1995). 17 ancestors in all, the oldest K945428 (1995). No later device cites it as a predicate yet.

  1. Root · 8 generations backK945512 HRSW Option for CT Twin FlashElscint, Inc. · 1995
  2. 7 generations backK970980 Cardiac Scoring for CT ScannersElscint, Inc. · 1997
  3. 6 generations backK982004 CT Coronary Artery Calcification Scoring (Cacs) Option for Advantage…General Electric Co. · 1998
  4. 5 generations backK020929 Smartscore 3.5; Smartscore 4.0; Smartscore 4.5GE Medical Systems · 2002
  5. 4 generations backK072737 CSCS-001A Calcium Scoring PackageToshiba America Medical Systems, In.C · 2007
  6. 3 generations backK083446 Cardiac Function Analysis, Calcium ScoringZiosoft, Inc. · 2009
  7. 2 generations backK111373 CT42 Cardiac Computed Tomography (CT) SoftwareCircle Cardiovascular Imaging, Inc. · 2011
  8. 1 generation backK203256 Imbio RV/LV SoftwareImbio, LLC · 2021
  9. This deviceK241847 Imbio PHA (4.0.0)Imbio, Inc. · 2024
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−8K945512HRSW Option for CT Twin FlashElscint, Inc.1995—
−7K970980Cardiac Scoring for CT ScannersElscint, Inc.1997—
−6K982004CT Coronary Artery Calcification Scoring (Cacs) Option for Advantage WindowsGeneral Electric Co.1998—
−5K020929Smartscore 3.5; Smartscore 4.0; Smartscore 4.5GE Medical Systems2002—
−4K072737CSCS-001A Calcium Scoring PackageToshiba America Medical Systems, In.C2007—
−3K083446Cardiac Function Analysis, Calcium ScoringZiosoft, Inc.2009—
−2K111373CT42 Cardiac Computed Tomography (CT) SoftwareCircle Cardiovascular Imaging, Inc.2011—
−1K203256Imbio RV/LV SoftwareImbio, LLC2021—
0 (this device)K241847Imbio PHA (4.0.0)Imbio, Inc.2024—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199510
199610
199710
199910
200020
200110
200220
FIG. 1 — Lineage of K241847, 1995–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in QIH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new QIH device

  1. #1 K213998 cvi42 Auto Imaging Software Applicationscore 23.5 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K203256Imbio RV/LV Software
Summary page 4
…892.2050 Product Code(s) QIH I Legally Marketed Predicate Devices 21 CFR 807.92(a)(3) Predicate # Predicate Trade Name (Primary Predicate is listed first) Product Code K203256 Imbio RV/LV QIH I Device Description Summary 21 CFR 807.92(a)(4) Imbio's PHA Software is a set of medical image…
Imbio, LLC2021—

Also cleared against K203256: 5 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 29 years and passes through 8 companies; a new generation was cleared every 3.5 years on median.
  • None of the 17 ancestors has a recall.
  • 5 other devices also cite its predicate K203256.

How does its category compare?

All QIH devices

QIH Automated Radiological Image Processing Software: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.

FDA decisions per year · QIH

94in 2025

2019: 22020: 112021: 192022: 252023: 452024: 642025: 942026 (partial year): 78
2007high 94 (2025) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · QIH

150in 2025

2020: 145 days median2021: 125 days median2022: 134 days median2023: 151 days median2024: 141 days median2025: 150 days median2026 (partial year): 130 days median
2007high 151 (2023) · low 125 (2021)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · QIH

1so far in 2026, the most since 2007

2026 (partial year): 1
2007high 1 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · QIH

4in 2025

2024: 22025: 4
2007high 4 (2025) · low 0 (2007)2025

MAUDE reports naming product code QIH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—00
20192—00
20201114500
20211912500
20222513400
20234515100
20246414102
20259415004
2026781301—

What is it indicated for?

The Imbio PHA Software device is designed to measure the maximal diameters of the right and left ventricles of the heart, the main pulmonary artery, and the ascending aorta from a volumetric CTPA acquisition and report the RV/LV and Pa/Ao ratios. PHA analyzes cases using an artificial intelligence algorithm to identify the location and measurements of the anatomy. The PHA software provides the user with annotated images showing measurements. Its results are not intended to be used on a stand-alone basis for clinical decision-making or otherwise preclude clinical assessment of CTPA cases.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K241847: Imbio PHA (4.0.0).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K241847

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026