MEDRAD Centargo CT Injection System; MEDRAD Centargo Day Set; MEDRAD Centargo Patient Line; MEDRAD Centargo Replacement Spike; MEDRAD ISI2 Module (ISI2)

K241849510(k) TraditionalCleared Nov 5, 2024131-day reviewClass II21 CFR 870.1650

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Imaxeon Pty, Ltd. · IZQ Injector, Contrast Medium, Automatic

Cleared on Nov 5, 2024 as substantially equivalent to K151048 (Bracco Injeneering, 2016) after a 131-day review. Its family tree reaches back 4 generations to 1995. 1 later device descends from it.

Decided
Nov 5, 2024
Review
131 days
Class
Class II
Product code
IZQ
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to K934086 (1995). 1 later device descends from it, 1 citing it directly.

  1. Root · 4 generations backK934086 Medrad Envision CT Injector and Qwik Fit SyringeMedrad, Inc. · 1995
  2. 3 generations backK983314 Premica CT Contrast Media Delivery SystemNycomed Amersham Imaging · 1999
  3. 2 generations backK062265 CT Expres Iii Contrast Media Delivery SystemSwiss Medical Care S.A. · 2006
  4. 1 generation backK151048 CT Expres 3D Contrast Media Delivery System, Bottle Spike Type B…Bracco Injeneering · 2016
  5. This deviceK241849 MEDRAD Centargo CT Injection System; MEDRAD Centargo Day Set; MEDRAD…Imaxeon Pty, Ltd. · 2024
  6. Descendant · cites it directly · 0 of its ownK252689 MEDRAD Centargo CT Injection System; MEDRAD Centargo Day Set; MEDRAD…Imaxeon Pty, Ltd. · 2025

Most influential descendants

Showing 1 of 1 · See all
  • K252689MEDRAD Centargo CT Injection System; MEDRAD Centargo Day Set; MEDRAD Centargo Patient…Imaxeon Pty, Ltd. · 2025 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K934086Medrad Envision CT Injector and Qwik Fit SyringeMedrad, Inc.1995—
−3K983314Premica CT Contrast Media Delivery SystemNycomed Amersham Imaging1999—
−2K062265CT Expres Iii Contrast Media Delivery SystemSwiss Medical Care S.A.2006—
−1K151048CT Expres 3D Contrast Media Delivery System, Bottle Spike Type B, Day Set III…Bracco Injeneering2016—
0 (this device)K241849MEDRAD Centargo CT Injection System; MEDRAD Centargo Day Set; MEDRAD Centargo…Imaxeon Pty, Ltd.2024—
+1K252689MEDRAD Centargo CT Injection System; MEDRAD Centargo Day Set; MEDRAD Centargo…Imaxeon Pty, Ltd.2025—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202510
FIG. 1 — Lineage of K241849, 1995–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in IZQ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new IZQ device

  1. #1 K241850 ulricheasyINJECT Max 2M (XD 10140)…score 12.7 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K151048CT Expres 3D Contrast Media Delivery System, Bottle Spike Type B, Day Set III HP…
Summary page 6
…èsTM 3D Contrast Media Delivery System PAGE 1 OF 17 MEDRAD® CENTARGO CT INJECTION SYSTEM- 510(K) SUMMARY 510(k) Number: K151048 Common Name: Automatic injector for contrast media Classification Name: Injector, Contrast…
Bracco Injeneering2016—
†K192370MEDRAD Stellant FLEX CT Injection System with Certegra WorkstationBayer Medical Care, Inc.20191

Also cleared against K151048: 1 other device →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K252689MEDRAD Centargo CT Injection System; MEDRAD Centargo Day Set; MEDRAD Centargo Patient…Imaxeon Pty, Ltd.20250

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 29 years and passes through 5 companies; a new generation was cleared every 8.8 years on median.
  • None of the 4 ancestors has a recall.
  • Of its descendants, K252689 (Imaxeon Pty, Ltd., 2025) has gone furthest, with 0 descendants of its own.
  • 1 other device also cites its predicate K151048.

How does its category compare?

All IZQ devices

IZQ Injector, Contrast Medium, Automatic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.

FDA decisions per year · IZQ

3in 2025

2007: 32010: 12016: 22017: 12020: 12021: 12024: 32025: 32026 (partial year): 1
2007high 3 (2007) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · IZQ

119in 2025

2007: 168 days median2024: 131 days median2025: 119 days median
2007high 168 (2007) · low 119 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · IZQ

2in 2011

2008: 12011: 2
2007high 2 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · IZQ

21in 2025

2007: 142008: 722009: 482010: 422011: 412012: 232013: 232014: 142015: 52016: 72017: 32018: 82019: 92020: 132021: 142022: 242023: 162024: 232025: 21
2007high 72 (2008) · low 3 (2017)2025

MAUDE reports naming product code IZQ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20073168014
20080—172
20090—048
20101—042
20110—241
20120—023
20130—023
20140—014
20150—05
20162—07
20171—03
20180—08
20190—09
20201—013
20211—014
20220—024
20230—016
20243131023
20253119021
20261—0—

What is it indicated for?

MEDRAD® Centargo CT Injection System is an automated contrast injection system that is indicated for the controlled, automatic administration, on the venous side, of ULTRAVIST® (lopromide), ISOVUE® (lopamidol), OPTIRAY® (loversol) or OMNIPAQUE™ (lohexol) contrast media as supplied in an approved Imaging Bulk Package (IBP) presentation and 0.9% Sodium Chloride Injection USP (saline) to human subjects undergoing examinations in computed tomography (CT).…

Read the full statement (254 words)

MEDRAD® Centargo CT Injection System is an automated contrast injection system that is

indicated for the controlled, automatic administration, on the venous side, of ULTRAVIST®

(lopromide), ISOVUE® (lopamidol), OPTIRAY® (loversol) or OMNIPAQUE™ (lohexol) contrast

media as supplied in an approved Imaging Bulk Package (IBP) presentation and 0.9% Sodium

Chloride Injection USP (saline) to human subjects undergoing examinations in computed

tomography (CT). The system is to be used by and under quasi-continuous supervision of trained

healthcare professionals in an appropriate licensed healthcare facility, in a room designated for

radiological procedures that involve intravascular administration of contrast agent.

The Day Set is used for a maximum time of twenty four (24) hours, or for a maximum of 25 bottles of

contrast media, whichever comes first. The Patient Line must be discarded after each patient

procedure. The Replacement Spike is for single-container use only and must be discarded with the

fluid container. Contrast media containers are to be discarded after their respective use times have

expired or the Day Set use life has expired, whichever occurs first.

Saline should only be used to deliver multiple single doses to multiple patients when used with the

MEDRAD® Centargo CT Injection System and the provided Saline Tag. Once the port of the saline

container is punctured, it should not be removed from the work area during the entire period of use.

Saline containers are to be discarded with the Day Set.

The ISI2 module is indicated for the specific purpose of allowing an injector to interface with an

imaging scanner.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K241849: MEDRAD Centargo CT Injection System; MEDRAD Centargo Day Set; MEDRAD Centargo Patient Line; MEDRAD Centargo Replacement Spike; MEDRAD ISI2 Module (ISI2).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K241849

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026