510(k) · Cleared
ClearedPhilips IntelliSite Pathology Solution
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Philips Medical Systems Nederland B.V. · PSY Whole Slide Imaging System
Cleared on Dec 2, 2024 after a 158-day review. The FDA summary names no predicate by number.
- Decided
- Dec 2, 2024
- Review
- 158 days
- Class
- Class II
- Product code
- PSY
- Recalls
- None
- Predicates
- 0
The FDA summary names no predicate by number.
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in PSY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new PSY device
- #1 K232202 Aperio GT 450 DXscore 34.5 · 2 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
The FDA summary names no predicate by number.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All PSY devicesPSY Whole Slide Imaging System: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.
FDA decisions per year · PSY
2in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · PSY
265in 2024
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · PSY
1so far in 2026, the most since 2007
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · PSY
1in 2023
MAUDE reports naming product code PSY, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 0 |
| 2011 | 0 | — | 0 | 0 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 0 | — | 0 | 0 |
| 2014 | 0 | — | 0 | 0 |
| 2015 | 0 | — | 0 | 0 |
| 2016 | 0 | — | 0 | 0 |
| 2017 | 2 | — | 0 | 0 |
| 2018 | 0 | — | 0 | 0 |
| 2019 | 2 | — | 0 | 1 |
| 2020 | 0 | — | 0 | 1 |
| 2021 | 2 | — | 0 | 0 |
| 2022 | 1 | — | 0 | 0 |
| 2023 | 1 | — | 0 | 1 |
| 2024 | 9 | 265 | 0 | 0 |
| 2025 | 2 | — | 0 | 0 |
| 2026 | 4 | 253 | 1 | — |
What is it indicated for?
The Philips IntelliSite Pathology Solution (PIPS) is an automated digital slide creation, viewing and management system. The PIPS is intended for in vitro diagnostic use as an aid to the pathologist to review and interpret digital images of surgical pathology slides prepared from formalin-fixed paraffin embedded (FFPE) tissue. The PIPS is not intended for use with frozen section, cytology, or non-FFPE hematopathology specimens. The PIPS comprises the…
Read the full statement (137 words)
The Philips IntelliSite Pathology Solution (PIPS) is an automated digital slide creation, viewing and management system. The PIPS is intended for in vitro diagnostic use as an aid to the pathologist to review and interpret digital images of surgical pathology slides prepared from formalin-fixed paraffin embedded (FFPE) tissue. The PIPS is not intended for use with frozen section, cytology, or non-FFPE hematopathology specimens.
The PIPS comprises the Inage Management System (IMS) the Ultra Fast Scanner (UFS) and Philips PP27QHD display or a Beacon C411W display. The PIPS is for creation and viewing of digital images of scanned glass slides that would otherwise be appropriate for manual visualization by conventional light microscopy. It is the responsibility of a qualified pathologist to employ appropriate procedures and safeguards to assure the validity of the interpretation of images obtained using PIPS.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K241871 · printed Nov 6, 2026
Cite this page
510(k) Report. “K241871: Philips IntelliSite Pathology Solution.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K241871
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026