510(k) · Cleared
ClearedCentroVena Central Venous Catheter (CVC) with the CentroVena One Insertion System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Becton Dickinson Inc. (Bd) · SEF Central Venous Catheter With Manual Insertion System
Cleared on Apr 9, 2025 as substantially equivalent to K190855 (Bard Access Systems, Inc. (Bard Has Joined Bd), 2019) after a 237-day review. Its family tree reaches back 10 generations to 2000. 4 of the 26 devices in its family, counting itself, have a Class I recall.
- Decided
- Apr 9, 2025
- Review
- 237 days
- Class
- Class II
- Product code
- SEF
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 10 generations to K001901 (2000). 25 ancestors in all, the oldest K830256 (1983). No later device cites it as a predicate yet. 4 of the 26 devices in this family, counting this one, have a Class I recall.
- Root · 10 generations backK001901 Poly Per-Q-Cath Picc Catheter,Model 3236100 and Poly Per-Q-Cath…C.R. Bard, Inc. · 2000 · Recalled
- 6 generations between
- 3 generations backK061179 Powerhickman Long-Term Intravascular CatheterC.R. Bard, Inc. · 2006
- 2 generations backK071538 Arrow, Arrowg+Ard and Arrowg+Ard Blue Plus Pressure Injectable…Arrow International, Inc. · 2007 · Recalled (Class I)
- 1 generation backK190855 BD Acute Central LineBard Access Systems, Inc. (Bard Has Joined Bd) · 2019
- This deviceK242429 CentroVena Central Venous Catheter (CVC) with the CentroVena One…Becton Dickinson Inc. (Bd) · 2025
Show all 10 generations
- Root · 10 generations backK001901 Poly Per-Q-Cath Picc Catheter,Model 3236100 and Poly Per-Q-Cath…C.R. Bard, Inc. · 2000 · Recalled
- 9 generations backK012902 Poly Per-Q-Cath Single Lumen Picc Catheter, Model 3143100; Poly…C.R. Bard, Inc. · 2001
- 8 generations backK031129 Poly Per-Q-Cath Picc Catheters; Poly RadpiccC.R. Bard, Inc. · 2003
- 7 generations backK033389 Powerpicc Catheters, Models 3175155, 3175135C.R. Bard, Inc. · 2004 · Recalled
- 6 generations backK050185 Powerhohn and Powerline CathetersC.R. Bard, Inc. · 2005
- 5 generations backK051417 6 FR FL Powerhohn and Powerline CatheterC.R. Bard, Inc. · 2005 · Recalled
- 4 generations backK051991 Powerpicc, Poly Per-Q-Cath, 6 FR TL Poly Per-Q-Cath, Power Hohn and…C.R. Bard, Inc. · 2005
- 3 generations backK061179 Powerhickman Long-Term Intravascular CatheterC.R. Bard, Inc. · 2006
- 2 generations backK071538 Arrow, Arrowg+Ard and Arrowg+Ard Blue Plus Pressure Injectable…Arrow International, Inc. · 2007 · Recalled (Class I)
- 1 generation backK190855 BD Acute Central LineBard Access Systems, Inc. (Bard Has Joined Bd) · 2019
- This deviceK242429 CentroVena Central Venous Catheter (CVC) with the CentroVena One…Becton Dickinson Inc. (Bd) · 2025
Class I recalls in this family
- K071538 Arrow, Arrowg+Ard and Arrowg+Ard Blue Plus…2 generations back · 2007
- K993691 Arrowg +Ard Blue Plus Antimicrobial Multi-Lumen…3 generations back · 2000
- K900263 Antimicrobial Multi-Lumen Central Venous Catheter3 generations back · 1990
- K862056 [Central Venous][Multi-Lumen] Catheter W/Flex Tip3 generations back · 1986
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −10 | K001901 | Poly Per-Q-Cath Picc Catheter,Model 3236100 and Poly Per-Q-Cath Midline… | C.R. Bard, Inc. | 2000 | 2 |
| −9 | K012902 | Poly Per-Q-Cath Single Lumen Picc Catheter, Model 3143100; Poly Per-Q-Cath… | C.R. Bard, Inc. | 2001 | — |
| −8 | K031129 | Poly Per-Q-Cath Picc Catheters; Poly Radpicc | C.R. Bard, Inc. | 2003 | — |
| −7 | K033389 | Powerpicc Catheters, Models 3175155, 3175135 | C.R. Bard, Inc. | 2004 | 1 |
| −6 | K050185 | Powerhohn and Powerline Catheters | C.R. Bard, Inc. | 2005 | — |
| −5 | K051417 | 6 FR FL Powerhohn and Powerline Catheter | C.R. Bard, Inc. | 2005 | 1 |
| −4 | K051991 | Powerpicc, Poly Per-Q-Cath, 6 FR TL Poly Per-Q-Cath, Power Hohn and Power Line | C.R. Bard, Inc. | 2005 | — |
| −3 | K061179 | Powerhickman Long-Term Intravascular Catheter | C.R. Bard, Inc. | 2006 | — |
| −2 | K071538 | Arrow, Arrowg+Ard and Arrowg+Ard Blue Plus Pressure Injectable Central Venous… | Arrow International, Inc. | 2007 | Class I |
| −1 | K190855 | BD Acute Central Line | Bard Access Systems, Inc. (Bard Has Joined Bd) | 2019 | — |
| 0 (this device) | K242429 | CentroVena Central Venous Catheter (CVC) with the CentroVena One Insertion… | Becton Dickinson Inc. (Bd) | 2025 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1983 | 1 | 0 |
| 1986 | 1 | 1 |
| 1989 | 1 | 0 |
| 1990 | 1 | 1 |
| 1996 | 1 | 0 |
| 1997 | 1 | 0 |
| 1999 | 1 | 0 |
| 2000 | 2 | 1 |
| 2001 | 2 | 0 |
| 2003 | 1 | 0 |
| 2004 | 1 | 0 |
| 2005 | 2 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
4 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K190855 | BD Acute Central LineSummary page 7…FOZ Predicate Device Regulation Number: 21 CFR 880.5200 Premarket Notification #: K190855 Manufacturer: Bard Access Systems, Inc… | 2019 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (4 Class I)
No FDA recall names this device.
Relatives with a Class I recall
Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.
- K071538Arrow, Arrowg+Ard and Arrowg+Ard Blue Plus Pressure Injectable Central Venous CatheterArrow International, Inc. · 2007 · 2 generations back · ◆ on the line of descent in FIG. 15 Class I recalls
- K993691Arrowg +Ard Blue Plus Antimicrobial Multi-Lumen Central Venous CatheterArrow Intl., Inc. · 2000 · 3 generations back · ◆ in the 2000 ancestors bar of FIG. 11 Class I recall
- K900263Antimicrobial Multi-Lumen Central Venous CatheterArrow Intl., Inc. · 1990 · 3 generations back · ◆ in the 1990 ancestors bar of FIG. 12 Class I recalls
- K862056[Central Venous][Multi-Lumen] Catheter W/Flex TipArrow Intl., Inc. · 1986 · 3 generations back · ◆ in the 1986 ancestors bar of FIG. 11 Class I recall
What does this lineage say?
- The line of descent spans 25 years and passes through 4 companies; a new generation was cleared every 1.1 years on median.
- 13 of the 25 ancestors have a recall of any class; 4 have a Class I recall.
- 2 other devices also cite its predicate K190855.
How does its category compare?
All SEF devicesSEF Central Venous Catheter With Manual Insertion System: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.
FDA decisions per year · SEF
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · SEF
Too few SEF 510(k)s in any year since 2007 to give a median.
Recalls per year · SEF
No recall names SEF since 2007.
Adverse event reports per year · SEF
No MAUDE report names SEF since 2007.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 0 |
| 2011 | 0 | — | 0 | 0 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 0 | — | 0 | 0 |
| 2014 | 0 | — | 0 | 0 |
| 2015 | 0 | — | 0 | 0 |
| 2016 | 0 | — | 0 | 0 |
| 2017 | 0 | — | 0 | 0 |
| 2018 | 0 | — | 0 | 0 |
| 2019 | 0 | — | 0 | 0 |
| 2020 | 0 | — | 0 | 0 |
| 2021 | 0 | — | 0 | 0 |
| 2022 | 0 | — | 0 | 0 |
| 2023 | 0 | — | 0 | 0 |
| 2024 | 0 | — | 0 | 0 |
| 2025 | 1 | — | 0 | 0 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
CentroVena Central Venous Catheter (CVC) Acute central venous catheters are indicated to provide short term access (< 30 days) to the central venous system. They are designed for administering IV fluids, blood products, drugs and parenteral nutrition solutions, as well as blood withdrawal, central venous pressure monitoring, and power injection of contrast media. 7F Triple Lumen Catheter Size, 16 cm and 20 cm Catheter Length, Distal Lumen, 10 mL/s Power…
Read the full statement (430 words)
CentroVena Central Venous Catheter (CVC)
Acute central venous catheters are indicated to provide short term access (< 30 days) to the central venous system. They are designed for administering IV fluids, blood products, drugs and parenteral nutrition solutions, as well as blood withdrawal, central venous pressure monitoring, and power injection of contrast media.
7F Triple Lumen Catheter Size, 16 cm and 20 cm Catheter Length, Distal Lumen, 10 mL/s Power Injection Flow Rate, 325 psi Maximum Power Injector Pressure Setting
7F Triple Lumen, 16 cm and 20 cm Catheter Length, Medial/Proximal Lumen, 9 mL/s Power Injection Flow Rate, 325 psi Maximum Power Injector Pressure Setting
7F Triple Lumen Catheter Size, 30 cm Catheter Length, Distal Lumen, 9 mL/s Power Injection Flow Rate, 325 psi Maximum Power Injector Pressure Setting
7F Triple Lumen Catheter Size, 30 cm Catheter Length, Medial/Proximal Lumen, 7 mL/s Power Injection Flow Rate, 325 psi Maximum Power Injector Pressure Setting
7F Dual Lumen Catheter Size, 16 cm and 20 cm Catheter Length, Distal Lumen, 10 mL/s Power Injection Flow Rate, 325 psi Maximum Power Injector Pressure Setting
7F Dual Lumen Catheter Size, 16 cm and 20 cm Catheter Length, Medial/Proximal Lumen, 10 mL/s Power Injection Flow Rate, 325 psi Maximum Power Injector Pressure Setting
CentroVena One Insertion System
The CentroVena One Insertion System is indicated to facilitate the insertion of the included central venous catheters.
Acute central venous catheters are indicated to provide short term access (< 30 days) to the central venous system. They are designed for administering IV fluids, blood products, drugs and parenteral nutrition solutions, as well as blood withdrawal, central venous pressure monitoring, and power injection of contrast media.
7F Triple Lumen Catheter Size, 16 cm and 20 cm Catheter Length, Distal Lumen, 10 mL/s Power Injection Flow Rate, 325 psi Maximum Power Injector Pressure Setting
7F Triple Lumen, 16 cm and 20 cm Catheter Length, Medial/Proximal Lumen, 9 mL/s Power Injection Flow Rate, 325 psi Maximum Power Injector Pressure Setting
7F Triple Lumen Catheter Size, 30 cm Catheter Length, Distal Lumen, 9 mL/s Power Injection Flow Rate, 325 psi Maximum Power Injector Pressure Setting
7F Triple Lumen Catheter Size, 30 cm Catheter Length, Medial/Proximal Lumen, 7 mL/s Power Injection Flow Rate, 325 psi Maximum Power Injector Pressure Setting
7F Dual Lumen Catheter Size, 16 cm and 20 cm Catheter Length, Distal Lumen, 10 mL/s Power Injection Flow Rate, 325 psi Maximum Power Injector Pressure Setting
7F Dual Lumen Catheter Size, 16 cm and 20 cm Catheter Length, Medial/Proximal Lumen, 10 mL/s Power Injection Flow Rate, 325 psi Maximum Power Injector Pressure Setting
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K242429 · printed Nov 6, 2026
Cite this page
510(k) Report. “K242429: CentroVena Central Venous Catheter (CVC) with the CentroVena One Insertion System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K242429
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026