510(k) Report

510(k) · Cleared

Cleared

uDR 380i Pro

K242515510(k) TraditionalCleared Oct 10, 202448-day reviewClass II21 CFR 892.1720

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Shanghai United Imaging Healthcare Co., Ltd. · IZL System, X-Ray, Mobile

Cleared on Oct 10, 2024 as substantially equivalent to K222339 (Shanghai United Imaging Healthcare Co., Ltd., 2022) after a 48-day review. Its family tree reaches back 4 generations to 2004.

Decided
Oct 10, 2024
Review
48 days
Class
Class II
Product code
IZL
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to K041763 (2004). No later device cites it as a predicate yet.

  1. Root · 4 generations backK041763 Shimadzu Mobile X-Ray System Mux-100D SeriesShimadzu Corp. · 2004 · Recalled
  2. 3 generations backK120062 DRX-Revolution Mobile X-Ray SystemCarestream Health, Inc. · 2012 · Recalled
  3. 2 generations backK191025 DRX-Revolution Mobile X-ray SystemCarestream Health, Inc. · 2019 · Recalled
  4. 1 generation backK222339 uDR 380i ProShanghai United Imaging Healthcare Co., Ltd. · 2022
  5. This deviceK242515 uDR 380i ProShanghai United Imaging Healthcare Co., Ltd. · 2024
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K041763Shimadzu Mobile X-Ray System Mux-100D SeriesShimadzu Corp.20041
−3K120062DRX-Revolution Mobile X-Ray SystemCarestream Health, Inc.20127
−2K191025DRX-Revolution Mobile X-ray SystemCarestream Health, Inc.20192
−1K222339uDR 380i ProShanghai United Imaging Healthcare Co., Ltd.2022—
0 (this device)K242515uDR 380i ProShanghai United Imaging Healthcare Co., Ltd.2024—
FIG. 1 — Lineage of K242515, 2004–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in IZL? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new IZL device

  1. #1 K242015 TOPAZ Mobile X-ray System (Models : TOPAZ-32D…score 19.9 · 19 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K222339uDR 380i Pro
Summary page 5
…n Number: 21 CFR 892.1720 Review Panel: Radiology 4. Identification of Predicate Device(s) Predicate Device Trade Name: uDR 380i Pro 510(k) Number: K222339 Device Name: Mobile Digital Medical X-ray Imaging System Manufacturer:Shanghai United Imaging Healthcare Co.,Ltd. Re…
Shanghai United Imaging Healthcare Co., Ltd.2022—
†K230175Digital Radiography CXDI-CS01Canon, Inc.2023—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 20 years and passes through 3 companies; a new generation was cleared every 7.1 years on median.
  • 3 of the 4 ancestors have a recall of any class.

How does its category compare?

All IZL devices

IZL System, X-Ray, Mobile: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.

FDA decisions per year · IZL

11in 2025

2007: 32008: 42009: 32010: 32011: 62012: 32014: 72015: 42016: 62017: 72018: 82019: 92020: 92021: 132022: 162023: 32024: 92025: 112026 (partial year): 6
2007high 16 (2022) · low 0 (2013)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · IZL

153in 2025

2007: 30 days median2008: 49 days median2009: 125 days median2010: 65 days median2011: 66 days median2012: 83 days median2014: 104 days median2015: 88 days median2016: 47 days median2017: 45 days median2018: 47 days median2019: 33 days median2020: 43 days median2021: 48 days median2022: 89 days median2023: 55 days median2024: 159 days median2025: 153 days median2026 (partial year): 157 days median
2007high 159 (2024) · low 30 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · IZL

47in 2025

2007: 72010: 42011: 62012: 52013: 102014: 42015: 42019: 22020: 12022: 12023: 62024: 52025: 472026 (partial year): 5
2007high 47 (2025) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · IZL

27in 2025

2007: 162008: 272009: 352010: 752011: 1182012: 242013: 172014: 512015: 302016: 332017: 352018: 272019: 402020: 482021: 472022: 322023: 772024: 392025: 27
2007high 118 (2011) · low 16 (2007)2025

MAUDE reports naming product code IZL, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007330716
2008449027
20093125035
2010365475
20116666118
2012383524
20130—1017
20147104451
2015488430
2016647033
2017745035
2018847027
2019933240
2020943148
20211348047
20221689132
2023355677
20249159539
2025111534727
202661575—

What is it indicated for?

uDR 380i Pro is a mobile digital radiography device intended to acquire X-ray images of the human anatomy for medical diagnosis. uDR 380i Pro can be used on both adult and pediatric patient by a qualified and trained operator. This device is not intended for mammography.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K242515: uDR 380i Pro.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K242515

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026