510(k) Report

510(k) · Cleared

Cleared

KIDS Arterial Filters

K242953510(k) SpecialCleared Dec 20, 202486-day reviewClass II21 CFR 870.4260

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Sorin Group Italia S.R.L. · DTM Filter, Blood, Cardiopulmonary Bypass, Arterial Line

Cleared on Dec 20, 2024 as substantially equivalent to K063255 (Sorin Group Italia S.R.L., 2007) and 1 other predicate after an 86-day review. Its family tree reaches back 4 generations to 1996.

Decided
Dec 20, 2024
Review
86 days
Class
Class II
Product code
DTM
Recalls
None
Predicates
2

Its longest line of descent runs back 4 generations to K961869 (1996). 5 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 4 generations backK961869 Dideco Newborn/Infant Arterial Filters: D735 Micro 20 and D736 Micro…Sorin Biomedical, Inc. · 1996
  2. 3 generations backK033987 D735 Micro 20 and D736 Micro 40 Newborn-Infant Arterial FiltersDideco S.P.A. · 2004
  3. 2 generations backK063255 D130 PH.I.S.I.O Dideco Kids Neonatal Arterial Filter with 40 Micron…Sorin Group Italia S.R.L. · 2007
  4. 1 generation backK072308 D131 PH.I.S.I.O Dideco Kids Infant Arterial Filter with 40 Micron…Sorin Group Italia S.R.L. · 2007
  5. This deviceK242953 KIDS Arterial FiltersSorin Group Italia S.R.L. · 2024
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K961869Dideco Newborn/Infant Arterial Filters: D735 Micro 20 and D736 Micro 40Sorin Biomedical, Inc.1996—
−3K033987D735 Micro 20 and D736 Micro 40 Newborn-Infant Arterial FiltersDideco S.P.A.2004—
−2K063255D130 PH.I.S.I.O Dideco Kids Neonatal Arterial Filter with 40 Micron Screen…Sorin Group Italia S.R.L.2007—
−1K072308D131 PH.I.S.I.O Dideco Kids Infant Arterial Filter with 40 Micron Screen…Sorin Group Italia S.R.L.2007—
0 (this device)K242953KIDS Arterial FiltersSorin Group Italia S.R.L.2024—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200010
FIG. 1 — Lineage of K242953, 1996–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DTM? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DTM device

  1. #1 K251744 Affinity Pixie™ Arterial Filter with Balance™…score 11.0 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K063255D130 PH.I.S.I.O Dideco Kids Neonatal Arterial Filter with 40 Micron Screen…
Summary page 6
…d and unmodified models have the same fundamental scientific technology and intended use: 510(k) Number: K063255 Device Trade Name: D130 PH.I.S.I.O DIDECO KIDS…
Sorin Group Italia S.R.L.2007—
*K072308D131 PH.I.S.I.O Dideco Kids Infant Arterial Filter with 40 Micron Screen…
Summary page 6
…cation: Class II Classification Panel: Cardiovascular 510(k) Number: K072308 Device Trade Name: D131 PH.I.S.I.O DIDECO KIDS…
Sorin Group Italia S.R.L.2007—

Also cleared against K063255: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 28 years and passes through 3 companies; a new generation was cleared every 7.4 years on median.
  • None of the 5 ancestors has a recall.
  • 1 other device also cites its predicate K063255.

How does its category compare?

All DTM devices

DTM Filter, Blood, Cardiopulmonary Bypass, Arterial Line: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.

FDA decisions per year · DTM

2in 2024

2007: 32008: 12009: 52010: 22011: 12012: 22013: 12023: 12024: 22026 (partial year): 1
2007high 5 (2009) · low 0 (2014)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DTM

246in 2009

2007: 60 days median2009: 246 days median
2007high 246 (2009) · low 60 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DTM

1in 2019

2008: 12019: 1
2007high 1 (2008) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DTM

4in 2024

2007: 82008: 22010: 32011: 82012: 62013: 92014: 642015: 342016: 272017: 152018: 232019: 52020: 12021: 12022: 42024: 4
2007high 64 (2014) · low 0 (2009)2025

MAUDE reports naming product code DTM, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200736008
20081—12
2009524600
20102—03
20111—08
20122—06
20131—09
20140—064
20150—034
20160—027
20170—015
20180—023
20190—15
20200—01
20210—01
20220—04
20231—00
20242—04
20250—00
20261—0—

What is it indicated for?

The device is indicated for use on the arterial line of the extracorporeal circuit during any procedure that requires cardiopulmonary bypass.

The device is indicated to trap and remove gaseous emboli as well as particulate debris that may be introduced through the arterial line. The device is indicated for use for 6 hours or less.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K242953: KIDS Arterial Filters.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K242953

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026