510(k) Report

510(k) · Cleared

Recalled · Class II · 2026

RayCare (2024A SP1)

K242992510(k) TraditionalCleared Apr 17, 2025203-day reviewClass II21 CFR 892.5050Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

RaySearch Laboratories AB (PUBL) · MUJ System, Planning, Radiation Therapy Treatment

Cleared on Apr 17, 2025 as substantially equivalent to K200487 (RaySearch Laboratories AB (PUBL), 2020) after a 203-day review. Its family tree reaches back 15 generations to 1996. It has been recalled 2 times.

Decided
Apr 17, 2025
Review
203 days
Class
Class II
Product code
MUJ
Recalls
2
Predicates
1

Its longest line of descent runs back 15 generations to K954874 (1996). 48 ancestors in all, the oldest K885054 (1989). No later device cites it as a predicate yet.

Other ancestors, by year cleared 2008: 1 other ancestor2003: 2 other ancestors2002: 2 other ancestors2000: 4 other ancestors2005: 1 other ancestor2001: 5 other ancestors1995: 2 other ancestors2004: 4 other ancestors1999: 1 other ancestor1997: 2 other ancestors1998: 1 other ancestor1996: 2 other ancestors1991: 3 other ancestors1993: 1 other ancestor1990: 1 other ancestor1989: 1 other ancestorK954874 · Spectef Protocol · GE Medical Systems · 1996K980914 · Emory Cardiac Tool Box · Emory University · 1998K992450 · Emory Cardiac Toolbox* 2.0 Executing on Nuclear Medicine Computers · Emory University · 1999K014033 · Emory Cardiac Toolbox 2.1 Executing on Nuclear Medicine Computers · Syntermed, Inc. · 2002K040141 · Emory Cardiac Toolbox Version 2.6 · Syntermed, Inc. · 2004K052379 · Mim 3.5 (Circa) · Mimvista Corp. · 2005×2: 2 generations cleared close together, K060816 (2006), K062163 (2006) K103785 · Mobile Mim · Mim Software, Inc. · 2011K112930 · Mobile Mim · Mim Software, Inc. · 2011K123230 · Mosaiq Oncology Information System · Impac Medical Systems, Inc. · 2012 · recalledK141572 · Mosaiq Oncology Information System · Impac Medical Systems, Inc. · 2014 · recalledK183034 · MOSAIQ Oncology Information System · Elekta, Inc. · 2018 · recalledK191384 · RayCare 2.3 · RaySearch Laboratories AB (PUBL) · 2019K200487 · RayCare 3.1 · RaySearch Laboratories AB (PUBL) · 2020 · recalled1990200020102020
  1. Root · 15 generations backK954874 Spectef ProtocolGE Medical Systems · 1996
  2. 11 generations between
  3. 3 generations backK183034 MOSAIQ Oncology Information SystemElekta, Inc. · 2018 · Recalled
  4. 2 generations backK191384 RayCare 2.3RaySearch Laboratories AB (PUBL) · 2019
  5. 1 generation backK200487 RayCare 3.1RaySearch Laboratories AB (PUBL) · 2020 · Recalled
  6. This deviceK242992 RayCare (2024A SP1)RaySearch Laboratories AB (PUBL) · 2025
Show all 15 generations
  1. Root · 15 generations backK954874 Spectef ProtocolGE Medical Systems · 1996
  2. 14 generations backK980914 Emory Cardiac Tool BoxEmory University · 1998
  3. 13 generations backK992450 Emory Cardiac Toolbox* 2.0 Executing on Nuclear Medicine ComputersEmory University · 1999
  4. 12 generations backK014033 Emory Cardiac Toolbox 2.1 Executing on Nuclear Medicine ComputersSyntermed, Inc. · 2002
  5. 11 generations backK040141 Emory Cardiac Toolbox Version 2.6Syntermed, Inc. · 2004
  6. 10 generations backK052379 Mim 3.5 (Circa)Mimvista Corp. · 2005
  7. 9 generations backK060816 Mim 4.0 (NeuroMimvista Corp. · 2006 · Recalled
  8. 8 generations backK062163 MimviewerMimvista Corp. · 2006
  9. 7 generations backK103785 Mobile MimMim Software, Inc. · 2011
  10. 6 generations backK112930 Mobile MimMim Software, Inc. · 2011
  11. 5 generations backK123230 Mosaiq Oncology Information SystemImpac Medical Systems, Inc. · 2012 · Recalled
  12. 4 generations backK141572 Mosaiq Oncology Information SystemImpac Medical Systems, Inc. · 2014 · Recalled
  13. 3 generations backK183034 MOSAIQ Oncology Information SystemElekta, Inc. · 2018 · Recalled
  14. 2 generations backK191384 RayCare 2.3RaySearch Laboratories AB (PUBL) · 2019
  15. 1 generation backK200487 RayCare 3.1RaySearch Laboratories AB (PUBL) · 2020 · Recalled
  16. This deviceK242992 RayCare (2024A SP1)RaySearch Laboratories AB (PUBL) · 2025
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−15K954874Spectef ProtocolGE Medical Systems1996—
−14K980914Emory Cardiac Tool BoxEmory University1998—
−13K992450Emory Cardiac Toolbox* 2.0 Executing on Nuclear Medicine ComputersEmory University1999—
−12K014033Emory Cardiac Toolbox 2.1 Executing on Nuclear Medicine ComputersSyntermed, Inc.2002—
−11K040141Emory Cardiac Toolbox Version 2.6Syntermed, Inc.2004—
−10K052379Mim 3.5 (Circa)Mimvista Corp.2005—
−9K060816Mim 4.0 (NeuroMimvista Corp.20061
−8K062163MimviewerMimvista Corp.2006—
−7K103785Mobile MimMim Software, Inc.2011—
−6K112930Mobile MimMim Software, Inc.2011—
−5K123230Mosaiq Oncology Information SystemImpac Medical Systems, Inc.20127
−4K141572Mosaiq Oncology Information SystemImpac Medical Systems, Inc.201411
−3K183034MOSAIQ Oncology Information SystemElekta, Inc.20182
−2K191384RayCare 2.3RaySearch Laboratories AB (PUBL)2019—
−1K200487RayCare 3.1RaySearch Laboratories AB (PUBL)20205
0 (this device)K242992RayCare (2024A SP1)RaySearch Laboratories AB (PUBL)2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198910
199010
199130
199310
199520
199620
199720
199810
199910
200040
200150
200220
200320
200440
200510
200810
FIG. 1 — Lineage of K242992, 1996–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MUJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MUJ device

  1. #1 K232799 syngo.via RT Image Suitescore 18.6 · 19 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K200487RayCare 3.1
Summary page 6
…5050 Product Code(s) MUJ Page 1 of 12 III. Legally Marketed Predicate Device Predicate # K200487 Predicate Trade Name RayCare 3B Product Code MUJ IV. Device Description Summary RayCare is an oncology information…
RaySearch Laboratories AB (PUBL)20205

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
May 20, 2026Class IIZ-2646-2026Under Investigation by firmBeam set delivery note issues in which there is potential data loss if the beam set delivery note is modified simultaneously and/or if a note is updated during a treatment session, the user is not notified of the change.
May 20, 2026Class IIZ-2647-2026Under Investigation by firmBeam set delivery note issues in which there is potential data loss if the beam set delivery note is modified simultaneously and/or if a note is updated during a treatment session, the user is not notified of the change.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 29 years and passes through 8 companies; a new generation was cleared every 1.7 years on median.
  • 12 of the 48 ancestors have a recall of any class.

How does its category compare?

All MUJ devices

MUJ System, Planning, Radiation Therapy Treatment: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.

FDA decisions per year · MUJ

10in 2025

2007: 42008: 92009: 162010: 112011: 92012: 82013: 52014: 92015: 132016: 52017: 72018: 72019: 92020: 92021: 112022: 82023: 102024: 92025: 102026 (partial year): 9
2007high 16 (2009) · low 4 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MUJ

186in 2025

2007: 67 days median2008: 63 days median2009: 84 days median2010: 56 days median2011: 103 days median2012: 59 days median2013: 64 days median2014: 108 days median2015: 78 days median2016: 80 days median2017: 30 days median2018: 53 days median2019: 56 days median2020: 104 days median2021: 87 days median2022: 168 days median2023: 140 days median2024: 122 days median2025: 186 days median2026 (partial year): 233 days median
2007high 233 (2026) · low 30 (2017)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MUJ

2in 2023

2007: 42008: 102009: 112010: 232011: 172012: 42013: 62014: 22015: 72016: 132017: 42018: 32019: 42020: 22021: 42022: 32023: 22026 (partial year): 2
2007high 23 (2010) · low 0 (2024)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MUJ

21in 2025

2007: 242008: 512009: 242010: 782011: 732012: 392013: 332014: 352015: 302016: 272017: 162018: 252019: 252020: 262021: 152022: 222023: 762024: 92025: 21
2007high 78 (2010) · low 9 (2024)2025

MAUDE reports naming product code MUJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007467424
20089631051
200916841124
201011562378
201191031773
2012859439
2013564633
20149108235
20151378730
20165801327
2017730416
2018753325
2019956425
20209104226
20211187415
20228168322
202310140276
2024912209
202510186021
202692332—

What is it indicated for?

RayCare is an oncology information system intended to provide information which is used to take decisions for diagnosis, treatment management, treatment planning, scheduling, treatment and follow-up of radiation therapy, medical oncology and surgical oncology. For these disciplines, as applicable, RayCare enables the user to define the clinical treatment intent, prescribe treatment, specify the detailed course of treatment delivery, manage the treatment…

Read the full statement (115 words)

RayCare is an oncology information system intended to provide information which is used to take decisions for diagnosis, treatment management, treatment planning, scheduling, treatment and follow-up of radiation therapy, medical oncology and surgical oncology.

For these disciplines, as applicable, RayCare enables the user to define the clinical treatment intent, prescribe treatment, specify the detailed course of treatment delivery, manage the treatment course and monitor the treatment course.

In the context of radiation therapy, the RayCare image viewer can be used for viewing images, annotating images, performing and saving image registrations as well as image fusion to enable offline image review of patient positioning during treatment delivery.

RayCare is not intended for use in diagnostic activities.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K242992: RayCare (2024A SP1).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K242992

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026