510(k) Report

510(k) · Cleared

Cleared

EasiSlush® Sodium Chloride Solution for Sterile Slush Preparation (BTLE-1250)

K243618510(k) TraditionalCleared Jun 17, 2025207-day reviewClass II21 CFR 876.5880

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Bridge TO Life · KDN System, Perfusion, Kidney

Cleared on Jun 17, 2025 as substantially equivalent to K191006 (Bridge TO Life, Ltd., 2019) after a 207-day review. Its family tree reaches back 3 generations to 1996.

Decided
Jun 17, 2025
Review
207 days
Class
Class II
Product code
KDN
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K944866 (1996). No later device cites it as a predicate yet.

  1. Root · 3 generations backK944866 Viaspan (Belzer UW - CSS)The Dupont Merck Pharmaceutical Co. · 1996 · Recalled
  2. 2 generations backK073693 CostorsolPreservation Solutions, Inc. · 2008 · Recalled
  3. 1 generation backK191006 EasiSlushBridge TO Life, Ltd. · 2019 · Recalled
  4. This deviceK243618 EasiSlush® Sodium Chloride Solution for Sterile Slush Preparation…Bridge TO Life · 2025
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K944866Viaspan (Belzer UW - CSS)The Dupont Merck Pharmaceutical Co.19961
−2K073693CostorsolPreservation Solutions, Inc.20082
−1K191006EasiSlushBridge TO Life, Ltd.20191
0 (this device)K243618EasiSlush® Sodium Chloride Solution for Sterile Slush Preparation (BTLE-1250)Bridge TO Life2025—
FIG. 1 — Lineage of K243618, 1996–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KDN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KDN device

  1. #1 K261644 Perfadex Plusscore 12.9 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K191006EasiSlush
Summary page 6
…0 PREDICATE DEVICE Company Device K Number Date Cleared Bridge to Life EasiSlush® K191006 Sept. 24, 2019 4.0 DEVICE DESCRIPTION EasiSlush® Sodium Chloride Solution for Sterile Slush Preparat…
Bridge TO Life, Ltd.20191

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 29 years and passes through 4 companies; a new generation was cleared every 11.2 years on median.
  • 3 of the 3 ancestors have a recall of any class.

How does its category compare?

All KDN devices

KDN System, Perfusion, Kidney: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.

FDA decisions per year · KDN

5in 2025

2008: 22009: 22010: 12012: 12014: 22015: 12016: 12018: 22019: 22020: 22021: 32022: 12023: 22024: 22025: 52026 (partial year): 3
2007high 5 (2025) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KDN

135in 2025

2021: 238 days median2025: 135 days median2026 (partial year): 66 days median
2007high 238 (2021) · low 135 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KDN

1in 2022

2010: 12022: 12026 (partial year): 1
2007high 1 (2010) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KDN

3in 2025

2008: 12016: 32017: 62018: 42019: 32020: 92021: 12025: 3
2007high 9 (2020) · low 0 (2007)2025

MAUDE reports naming product code KDN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20082—01
20092—00
20101—10
20110—00
20121—00
20130—00
20142—00
20151—00
20161—03
20170—06
20182—04
20192—03
20202—09
2021323801
20221—10
20232—00
20242—00
2025513503
20263661—

What is it indicated for?

EasiSlush® Sodium Chloride Solution for Sterile Slush Preparation (BTLE-1250) is intended for topical cooling of in situ, abdominal donor organs during intraoperative recovery from the donor. It is also intended to maintain organ hypothermia during storage and transport to the transplant recipient. EasiSlush® Sodium Chloride Solution for Sterile Slush Preparation (BTLE-1250) is used to establish, and maintain hypothermia of donor organs during recovery…

Read the full statement (346 words)

EasiSlush® Sodium Chloride Solution for Sterile Slush Preparation (BTLE-1250) is intended for topical cooling of in situ, abdominal donor organs during intraoperative recovery from the donor. It is also intended to maintain organ hypothermia during storage and transport to the transplant recipient. EasiSlush® Sodium Chloride Solution for Sterile Slush Preparation (BTLE-1250) is used to establish, and maintain hypothermia of donor organs during recovery, storage, and transport.

It is also indicated for use during open surgical procedures such as cardiovascular, abdominal, and transplant surgeries.

Organ Recovery

Prior to organ recovery, EasiSlush® Sodium Chloride Solution for Sterile Slush Preparation (BTLE-1250) is delivered to the open peritoneal cavity of the donor to assist in creating hypothermia by topically cooling external surfaces of organs for recovery. During organ recovery, if ice crystals are no longer visible, the temperature of the saline solution will begin to rise and additional slushed solution may be delivered per established transplant team procedures. (Temperature rise may be assessed with temperature probes, being careful that the probe is measuring the solution and is not in contact with the organ).

Organ Storage/Transport

For organ storage/transport, EasiSlush® Sodium Chloride Solution for Sterile Slush Preparation (BTLE-1250) may be used to topically cool external surfaces of a sterile, sealed, primary organ bag containing chilled preservation solution and the organ. In this application, the slushed solution may be added to a secondary bag or to a tertiary hard container to surround the primary organ bag. Once bagged, the organ can be placed in a bed of non-sterile ice in an insulated transport container, which is then closed. Actual use should follow standard practices of the OPO or hospital for transporting and storing specific types of donor organs using sterile, slush solutions.

Surgical Procedure

During surgical procedures, EasiSlush® Sodium Chloride Solution for Sterile Slush Preparation (BTLE-1250) is delivered to assist in creating hypothermia by topically cooling external surfaces of organs. During the procedure, if ice crystals are no longer visible, the temperature of the saline solution will begin to rise and additional slushed solution may be delivered per established surgical team procedures.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K243618: EasiSlush® Sodium Chloride Solution for Sterile Slush Preparation (BTLE-1250).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K243618

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026