510(k) Report

510(k) · Cleared

Cleared

0.014” Willow Guidewire

K243756510(k) TraditionalCleared Jul 17, 2025223-day reviewClass II21 CFR 870.1330

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Arbor Endovascular, LLC · MOF Guide, Wire, Catheter, Neurovasculature

Cleared on Jul 17, 2025 as substantially equivalent to K202522 (Stryker Neurovascular, 2020) after a 223-day review. Its family tree reaches back 5 generations to 2000. 4 later devices descend from it.

Decided
Jul 17, 2025
Review
223 days
Class
Class II
Product code
MOF
Recalls
None
Predicates
1

Its longest line of descent runs back 5 generations to K002212 (2000). 7 ancestors in all, the oldest K913074 (1991). 4 later devices descend from it, 1 citing it directly.

  1. Root · 5 generations backK002212 Mirage Hydrophilic Guidewire, Model 103-0608Micro Therapeutics, Inc. · 2000
  2. 4 generations backK032146 PVS 1300 Synchro 0.014 & PVS 1600 Synchro 0.010 Guide WiresPrecision Vascular Systems, Inc. · 2003 · Recalled
  3. 3 generations backK050964 PV 1900 Synchro 0.016 GuidewireBoston Scientific - Precision Vascular · 2005 · Recalled
  4. 2 generations backK053268 PVS 2000 SYNCHRO2 GuidewireBoston Scientific - Precision Vascular · 2006 · Recalled
  5. 1 generation backK202522 Synchro SELECT GuidewireStryker Neurovascular · 2020 · Recalled
  6. This deviceK243756 0.014” Willow GuidewireArbor Endovascular, LLC · 2025
  7. Descendant · cites it directly · 3 of its ownK253168 0.014” Willow GuidewireArbor Endovascular, LLC · 2025
  8. Descendant · 2 generations on · 1 of its ownK260130 Willow 18 GuidewireArbor Endovascular, LLC · 2026
  9. Descendant · 2 generations on · 0 of its ownK262424 Willow 12 GuidewireArbor Endovascular, LLC · 2026
  10. Descendant · 3 generations on · 0 of its ownK260537 Willow 24 GuidewireArbor Endovascular, LLC · 2026

Most influential descendants

Showing 4 of 4 · See all
  • K2531680.014” Willow GuidewireArbor Endovascular, LLC · 2025 · cites it directly3descendants
  • K260130Willow 18 GuidewireArbor Endovascular, LLC · 2026 · 2 generations on1descendant
  • K262424Willow 12 GuidewireArbor Endovascular, LLC · 2026 · 2 generations on0descendants
  • K260537Willow 24 GuidewireArbor Endovascular, LLC · 2026 · 3 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K002212Mirage Hydrophilic Guidewire, Model 103-0608Micro Therapeutics, Inc.2000—
−4K032146PVS 1300 Synchro 0.014 & PVS 1600 Synchro 0.010 Guide WiresPrecision Vascular Systems, Inc.20031
−3K050964PV 1900 Synchro 0.016 GuidewireBoston Scientific - Precision Vascular20056
−2K053268PVS 2000 SYNCHRO2 GuidewireBoston Scientific - Precision Vascular200613
−1K202522Synchro SELECT GuidewireStryker Neurovascular20201
0 (this device)K2437560.014” Willow GuidewireArbor Endovascular, LLC2025—
+1K2531680.014” Willow GuidewireArbor Endovascular, LLC2025—
+2K260130Willow 18 GuidewireArbor Endovascular, LLC2026—
+2K262424Willow 12 GuidewireArbor Endovascular, LLC2026—
+3K260537Willow 24 GuidewireArbor Endovascular, LLC2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199110
199710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202510
202630
FIG. 1 — Lineage of K243756, 2000–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MOF? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MOF device

  1. #1 K253168 0.014” Willow Guidewirescore 17.9 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K202522Synchro SELECT Guidewire
Summary page 5
…21 CFR 870.1330 – Class II Product Code: MOF, DQX Legally Marketed Predicate Device: Synchro SELECT Guidewire (K202522) Device Description: Like the predicate device, the 0.014” Willow Guidewire is a single-use product with a shapeable tip availab…
Stryker Neurovascular20201

Also cleared against K202522: 1 other device →

What descends from it? (4)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K2531680.014” Willow GuidewireArbor Endovascular, LLC20253

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 25 years and passes through 5 companies; a new generation was cleared every 3.0 years on median.
  • 4 of the 7 ancestors have a recall of any class.
  • Of its descendants, K253168 (Arbor Endovascular, LLC, 2025) has gone furthest, with 3 descendants of its own.
  • 1 other device also cites its predicate K202522.

How does its category compare?

All MOF devices

MOF Guide, Wire, Catheter, Neurovasculature: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.

FDA decisions per year · MOF

11so far in 2026, the most since 2007

2011: 22014: 22015: 32016: 42017: 12018: 22019: 42020: 42022: 12023: 42024: 22025: 52026 (partial year): 11
2007high 11 (2026) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MOF

172in 2025

2015: 133 days median2016: 61 days median2019: 58 days median2020: 36 days median2023: 199 days median2025: 172 days median2026 (partial year): 192 days median
2007high 199 (2023) · low 36 (2020)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MOF

No recall names MOF since 2007.

Adverse event reports per year · MOF

135in 2025

2008: 12012: 22013: 22015: 52016: 32017: 152018: 112019: 122020: 182021: 392022: 922023: 912024: 952025: 135
2007high 135 (2025) · low 0 (2007)2025

MAUDE reports naming product code MOF, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—01
20090—00
20100—00
20112—00
20120—02
20130—02
20142—00
2015313305
201646103
20171—015
20182—011
2019458012
2020436018
20210—039
20221—092
20234199091
20242—095
202551720135
2026111920—

What is it indicated for?

The 0.014” Willow Guidewire is intended for general intravascular use, including neurovascular and peripheral vasculatures. It can be used to selectively introduce and position catheters and other interventional devices within the peripheral and neuro vasculature. This device should be used only by physicians trained in percutaneous, intravascular techniques and procedures.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K243756: 0.014” Willow Guidewire.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K243756

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026