510(k) · Cleared
ClearedMedical Diode Laser (UTU3-F7B,UTU3-F7W,UTU3-G7B,UTU3-G7W,UTU-G20B,UTU-G20W)
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Wuhan Pioon Technology Co., Ltd. · NVK Laser, Dental, Soft Tissue
Cleared on May 8, 2025 as substantially equivalent to K210367 (Guilin Woodpecker Medical Instrument Co., Ltd., 2022) after a 153-day review. Its family tree reaches back 21 generations to 1995.
- Decided
- May 8, 2025
- Review
- 153 days
- Class
- Class II
- Product code
- NVK
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 21 generations to K943450 (1995). 237 ancestors in all, the oldest K800617 (1980). No later device cites it as a predicate yet.
- Root · 21 generations backK943450 Arthrocare Arthroscopic Electrosurgery System Model 970Arthrocare Corp. · 1995
- 17 generations between
- 3 generations backK170500 SIROLaser Advance+Dentsply Sirona · 2017
- 2 generations backK180044 SIROLaser BlueDentsply Sirona · 2018
- 1 generation backK210367 D-Laser Blue, D-Laser 16Guilin Woodpecker Medical Instrument Co., Ltd. · 2022
- This deviceK243764 Medical Diode Laser…Wuhan Pioon Technology Co., Ltd. · 2025
Show all 21 generations
- Root · 21 generations backK943450 Arthrocare Arthroscopic Electrosurgery System Model 970Arthrocare Corp. · 1995
- 20 generations backK961069 Arthrocare Urologic Multi-Electrode Electrosurgery SystemArthrocare Corp. · 1996
- 19 generations backK962445 Arthrocare Dental Electrosurgery SystemArthrocare Corp. · 1996
- 18 generations backK964849 Arthrocare Dermatologic Electrosurgery SystemArthrocare Corp. · 1997
- 17 generations backK973478 Arthrocare Sinus Electrosurgery SystemArthrocare Corp. · 1998
- 16 generations backK981870 Visage Cosmetic Surgery SystemArthrocare Corp. · 1998
- 15 generations backK000944 Thermage Thermacool SystemThermage, Inc. · 2000
- 14 generations backK013034 Modification to: Thermacool IiaThermage, Inc. · 2001
- 13 generations backK013639 Thermage Thermacool TC SystemThermage, Inc. · 2002
- 12 generations backK021402 Thermage Thermacool TC SystemThermage, Inc. · 2002
- 11 generations backK030142 Thermacool TC SystemThermage, Inc. · 2003
- 10 generations backK031671 Polaris WRSyneron Medical, Ltd. · 2003
- 9 generations backK041959 Polaris DS/CometSyneron Medical, Ltd. · 2004
- 8 generations backK053540 Intermedic Diode Laser Family 810NM and 980NM (and the Delivery…Intermedic Arfran, SA · 2006
- 7 generations backK071295 100W Ceralas D 980NM Diode LaserBiolitec, Inc. · 2007
- 6 generations backK072106 150W Ceralas D 980NM Diode LaserBiolitec, Inc. · 2007
- 5 generations backK082938 EzlaseBiolase Technology, Inc. · 2008
- 4 generations backK121286 EPIC 10Biolase Technology, Inc. · 2012
- 3 generations backK170500 SIROLaser Advance+Dentsply Sirona · 2017
- 2 generations backK180044 SIROLaser BlueDentsply Sirona · 2018
- 1 generation backK210367 D-Laser Blue, D-Laser 16Guilin Woodpecker Medical Instrument Co., Ltd. · 2022
- This deviceK243764 Medical Diode Laser…Wuhan Pioon Technology Co., Ltd. · 2025
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −21 | K943450 | Arthrocare Arthroscopic Electrosurgery System Model 970 | Arthrocare Corp. | 1995 | — |
| −20 | K961069 | Arthrocare Urologic Multi-Electrode Electrosurgery System | Arthrocare Corp. | 1996 | — |
| −19 | K962445 | Arthrocare Dental Electrosurgery System | Arthrocare Corp. | 1996 | — |
| −18 | K964849 | Arthrocare Dermatologic Electrosurgery System | Arthrocare Corp. | 1997 | — |
| −17 | K973478 | Arthrocare Sinus Electrosurgery System | Arthrocare Corp. | 1998 | — |
| −16 | K981870 | Visage Cosmetic Surgery System | Arthrocare Corp. | 1998 | — |
| −15 | K000944 | Thermage Thermacool System | Thermage, Inc. | 2000 | — |
| −14 | K013034 | Modification to: Thermacool Iia | Thermage, Inc. | 2001 | — |
| −13 | K013639 | Thermage Thermacool TC System | Thermage, Inc. | 2002 | — |
| −12 | K021402 | Thermage Thermacool TC System | Thermage, Inc. | 2002 | — |
| −11 | K030142 | Thermacool TC System | Thermage, Inc. | 2003 | — |
| −10 | K031671 | Polaris WR | Syneron Medical, Ltd. | 2003 | — |
| −9 | K041959 | Polaris DS/Comet | Syneron Medical, Ltd. | 2004 | — |
| −8 | K053540 | Intermedic Diode Laser Family 810NM and 980NM (and the Delivery Accessories… | Intermedic Arfran, SA | 2006 | — |
| −7 | K071295 | 100W Ceralas D 980NM Diode Laser | Biolitec, Inc. | 2007 | — |
| −6 | K072106 | 150W Ceralas D 980NM Diode Laser | Biolitec, Inc. | 2007 | — |
| −5 | K082938 | Ezlase | Biolase Technology, Inc. | 2008 | — |
| −4 | K121286 | EPIC 10 | Biolase Technology, Inc. | 2012 | — |
| −3 | K170500 | SIROLaser Advance+ | Dentsply Sirona | 2017 | — |
| −2 | K180044 | SIROLaser Blue | Dentsply Sirona | 2018 | — |
| −1 | K210367 | D-Laser Blue, D-Laser 16 | Guilin Woodpecker Medical Instrument Co., Ltd. | 2022 | — |
| 0 (this device) | K243764 | Medical Diode Laser (UTU3-F7B,UTU3-F7W,UTU3-G7B,UTU3-G7W,UTU-G20B,UTU-G20W) | Wuhan Pioon Technology Co., Ltd. | 2025 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1980 | 1 | 0 |
| 1985 | 1 | 0 |
| 1987 | 2 | 0 |
| 1988 | 1 | 0 |
| 1989 | 2 | 0 |
| 1990 | 2 | 0 |
| 1991 | 3 | 0 |
| 1992 | 4 | 0 |
| 1993 | 6 | 0 |
| 1994 | 9 | 0 |
| 1995 | 14 | 0 |
| 1996 | 16 | 0 |
| 1997 | 22 | 0 |
| 1998 | 14 | 0 |
| 1999 | 11 | 0 |
| 2000 | 16 | 0 |
| 2001 | 17 | 0 |
| 2002 | 22 | 0 |
| 2003 | 19 | 0 |
| 2004 | 11 | 0 |
| 2005 | 7 | 0 |
| 2006 | 2 | 0 |
| 2007 | 6 | 0 |
| 2008 | 4 | 0 |
| 2009 | 2 | 0 |
| 2010 | 1 | 0 |
| 2011 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in NVK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new NVK device
- #1 K210367 D-Laser Blue, D-Laser 16score 20.7 · 20 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K210367 | D-Laser Blue, D-Laser 16Summary page 5…y Class: II Primary Product Code: NVK Secondary Product Code: GEX, ILY 3. Predicate Device Item Predicate Device Reference Devices 510(k) K210367 K232222 K163128 Number Page 1 of 10… | 2022 |
| † | K232222 | Primo Dental Laser (Primo, Primo Komfort, Primo Lite, Primo Blue, and Primo Triplo) | 2023 |
| † | K163128 | Epic Pro | 2017 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 30 years and passes through 9 companies; a new generation was cleared every 10 months on median.
- 10 of the 237 ancestors have a recall of any class.
- 3 other devices also cite its predicate K210367.
How does its category compare?
All NVK devicesNVK Laser, Dental, Soft Tissue: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.
FDA decisions per year · NVK
2in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · NVK
139in 2022
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · NVK
1in 2023
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · NVK
1in 2024
MAUDE reports naming product code NVK, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 1 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 0 |
| 2011 | 0 | — | 0 | 0 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 0 | — | 0 | 0 |
| 2014 | 0 | — | 0 | 0 |
| 2015 | 0 | — | 0 | 4 |
| 2016 | 0 | — | 0 | 0 |
| 2017 | 0 | — | 0 | 0 |
| 2018 | 0 | — | 0 | 0 |
| 2019 | 0 | — | 0 | 0 |
| 2020 | 0 | — | 0 | 0 |
| 2021 | 4 | 277 | 0 | 0 |
| 2022 | 5 | 139 | 0 | 0 |
| 2023 | 1 | — | 1 | 0 |
| 2024 | 2 | — | 0 | 1 |
| 2025 | 2 | — | 0 | 0 |
| 2026 | 2 | — | 0 | — |
What is it indicated for?
The UTU series Medical Diode Laser are intended for intra- and extra-oral surgery including incision, excision, hemostasis, coagulation and vaporization of soft tissue including marginal and inter-dental and epithelial lining of free gingiva and are indicated for: frenectomy; frenotomy; biopsy; operculectomy; implant recovery; gingivectomy; gingivoplasty; gingival troughing; crown lengthening; hemostasis of donor site; removal of granulation tissue…
Read the full statement (259 words)
The UTU series Medical Diode Laser are intended for intra- and extra-oral surgery including incision, excision, hemostasis, coagulation and vaporization of soft tissue including marginal and inter-dental and epithelial lining of free gingiva and are indicated for: frenectomy; frenotomy; biopsy; operculectomy; implant recovery; gingivectomy; gingivoplasty; gingival troughing; crown lengthening; hemostasis of donor site; removal of granulation tissue; laser assisted flap surgery; debridement of diseased epithelial lining; incisions and draining of abscesses; tissue retraction for impressions; papillectomy; vestibuloplasty; excision of lesions; exposure of unerupted/partially erupted teeth; removal of hyperplastic tissues; treatment of aphthous ulcers; leukoplakia; laser removal of diseased, infected, inflamed and necrosed soft tissue within the periodontal pocket; sulcular debridement (removal of diseased, infected, inflamed and necrosed soft tissue in the periodontal pocket to improve clinical indices including gingival index,gingival bleeding index, probe depth, attachment loss and tooth inability); pulpotomy; pulpotomy as adjunct to root canal therapy; fibroma removal; gingival incision and excision; treatment of canker sores; herpetic ulcers of the oral mucosa; laser soft tissue curettage; reduction of gingival hypertrophy.
Whitening: The UTU series Medical Diode Laser are indicated for light activation for bleaching materials for teeth whitening and for laser-assisted whitening/bleaching of teeth.
Low Level Laser Therapy: The UTU series Medical Diode Laser are intended to emit energy in the red and infrared spectrum to provide topical heating for the purpose of elevating tissue temperature for the temporary relief of minor muscle and joint pain and stiffness, minor arthritis pain, or muscle spasm, and for the temporary increase in local blood circulation and/or temporary relaxation of muscles.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K243764 · printed Nov 6, 2026
Cite this page
510(k) Report. “K243764: Medical Diode Laser (UTU3-F7B,UTU3-F7W,UTU3-G7B,UTU3-G7W,UTU-G20B,UTU-G20W).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K243764
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026