510(k) Report

510(k) · Cleared

Cleared

Elfor-L

K243852510(k) TraditionalCleared Apr 14, 2025119-day reviewClass II21 CFR 870.2100

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Elfi-Tech, Ltd. · DPW Flowmeter, Blood, Cardiovascular

Cleared on Apr 14, 2025 as substantially equivalent to K974285 (Perimed, Inc., 1998) and 1 other predicate after a 119-day review. Its family tree reaches back 3 generations to 1993.

Decided
Apr 14, 2025
Review
119 days
Class
Class II
Product code
DPW
Recalls
None
Predicates
2

Its longest line of descent runs back 3 generations to K922368 (1993). 7 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2001: 1 other ancestor1994: 1 other ancestor1993: 1 other ancestor1995: 1 other ancestorK922368 · Periflux PF4001 Laser Doppler Flowmeter · Perimed, Inc. · 1993K974285 · Periflux System 5000 Modular Laser Doppler System Main Unit Model PF 5001, Including PF 5010 LDPM Unit · Perimed, Inc. · 1998K152930 · PeriFlux6000 · Perimed AB · 20161990200020102020
  1. Root · 3 generations backK922368 Periflux PF4001 Laser Doppler FlowmeterPerimed, Inc. · 1993
  2. 2 generations backK974285 Periflux System 5000 Modular Laser Doppler System Main Unit Model PF…Perimed, Inc. · 1998
  3. 1 generation backK152930 PeriFlux6000Perimed AB · 2016
  4. This deviceK243852 Elfor-LElfi-Tech, Ltd. · 2025
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K922368Periflux PF4001 Laser Doppler FlowmeterPerimed, Inc.1993—
−2K974285Periflux System 5000 Modular Laser Doppler System Main Unit Model PF 5001…Perimed, Inc.1998—
−1K152930PeriFlux6000Perimed AB2016—
0 (this device)K243852Elfor-LElfi-Tech, Ltd.2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199310
199410
199510
200110
FIG. 1 — Lineage of K243852, 1993–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DPW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DPW device

  1. #1 K251114 FloPatch FP120score 13.7 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K974285Periflux System 5000 Modular Laser Doppler System Main Unit Model PF 5001, Including PF…
Summary page 5
…PW III. PREDICATE DEVICE ELFI-TECH Ltd. believes that Elfor-L is substantially equivalent to the following predicate device: • Perimed Inc. PeriFlux 5000 cleared under K974285, Product code DPW, Regulation number 21 CFR 870.2100 and in subsequent submission under K152930, PeriFlux 6000, Product code…
Perimed, Inc.1998—
*K152930PeriFlux6000
Summary page 5
…following predicate device: • Perimed Inc. PeriFlux 5000 cleared under K974285, Product code DPW, Regulation number 21 CFR 870.2100 and in subsequent submission under K152930, PeriFlux 6000, Product code DPW, Regulation number 21 CFR 870.2100. IV. DEVICE DESCRIPTION The Elfor-L device is making use…
Perimed AB2016—

Also cleared against K974285: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 32 years and passes through 3 companies; a new generation was cleared every 8.9 years on median.
  • None of the 7 ancestors has a recall.
  • 1 other device also cites its predicate K974285.

How does its category compare?

All DPW devices

DPW Flowmeter, Blood, Cardiovascular: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.

FDA decisions per year · DPW

3in 2025

2007: 12008: 12010: 22011: 42012: 12013: 22015: 32016: 12018: 22019: 32020: 22021: 22022: 32023: 12024: 12025: 32026 (partial year): 2
2007high 4 (2011) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DPW

119in 2025

2011: 89 days median2015: 275 days median2019: 169 days median2022: 136 days median2025: 119 days median
2007high 275 (2015) · low 89 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DPW

1in 2025

2007: 42010: 12012: 12017: 12025: 1
2007high 4 (2007) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DPW

6in 2025

2009: 12011: 12013: 32014: 82015: 122016: 12017: 22019: 32020: 42021: 62022: 12023: 22024: 42025: 6
2007high 12 (2015) · low 0 (2007)2025

MAUDE reports naming product code DPW, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—40
20081—00
20090—01
20102—10
201148901
20121—10
20132—03
20140—08
20153275012
20161—01
20170—12
20182—00
2019316903
20202—04
20212—06
2022313601
20231—02
20241—04
2025311916
20262—0—

What is it indicated for?

The Elfor L is intended for measuring micro-vascular perfusion in skin and muscle in humans. It is intended to be used for

clinical research applications and pre clinical research applications.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K243852: Elfor-L.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K243852

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026