510(k) Report

510(k) · Cleared

Recalled · Class II · 2026

Elegance® Anterior Cervical plate

K243904510(k) SpecialCleared Jan 14, 202526-day reviewClass II21 CFR 888.3060Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Clariance · KWQ Appliance, Fixation, Spinal Intervertebral Body

Cleared on Jan 14, 2025 as substantially equivalent to K220182 (Clariance, 2022) after a 26-day review. Its family tree reaches back 5 generations to 1995. It has been recalled once.

Decided
Jan 14, 2025
Review
26 days
Class
Class II
Product code
KWQ
Recalls
1
Predicates
1

Its longest line of descent runs back 5 generations to K953730 (1995). No later device cites it as a predicate yet.

  1. Root · 5 generations backK953730 Codman Anterior Cervical Plate SystemJohnson & Johnson Professionals, Inc. · 1995
  2. 4 generations backK013877 Codman Slim-Loc SystemCodman & Shurtleff, Inc. · 2001
  3. 3 generations backK052552 Hybrid Anterior Cervical Plate SystemDepuy Spine, Inc. · 2005 · Recalled
  4. 2 generations backK103491 Skyline Anterior Cervical Plate SystemA Johnson & Johnson Company · 2011
  5. 1 generation backK220182 Aggeris™-CClariance · 2022
  6. This deviceK243904 Elegance® Anterior Cervical plateClariance · 2025
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K953730Codman Anterior Cervical Plate SystemJohnson & Johnson Professionals, Inc.1995—
−4K013877Codman Slim-Loc SystemCodman & Shurtleff, Inc.2001—
−3K052552Hybrid Anterior Cervical Plate SystemDepuy Spine, Inc.20057
−2K103491Skyline Anterior Cervical Plate SystemA Johnson & Johnson Company2011—
−1K220182Aggeris™-CClariance2022—
0 (this device)K243904Elegance® Anterior Cervical plateClariance2025—
FIG. 1 — Lineage of K243904, 1995–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KWQ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KWQ device

  1. #1 K233640 Segmental Plating System (SPS);IdentiTi SPS…score 21.9 · 31 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K220182Aggeris™-C
Summary page 5
…sification Name: Spinal intervertebral body fixation orthosis, 21 CFR § 888.3060 Regulatory Class: Class II Product Code: KWQ Predicate Device: Aggeris™-C, CLARIANCE (K220182) Device Description The Elegance® Anterior Cervical plate is designed for use as a cervical plate system. The devi…
Clariance2022—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Feb 20, 2026Class IIZ-1821-2026Process change controlDue to a quality issue regarding the presence of burr on the finished cervical plate product.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 30 years and passes through 5 companies; a new generation was cleared every 5.3 years on median.
  • 1 of the 5 ancestors has a recall of any class.

How does its category compare?

All KWQ devices

KWQ Appliance, Fixation, Spinal Intervertebral Body: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.

FDA decisions per year · KWQ

7in 2025

2007: 272008: 322009: 232010: 232011: 222012: 262013: 222014: 172015: 252016: 152017: 202018: 222019: 262020: 262021: 172022: 182023: 162024: 172025: 72026 (partial year): 10
2007high 32 (2008) · low 7 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KWQ

64in 2025

2007: 101 days median2008: 70 days median2009: 90 days median2010: 104 days median2011: 95 days median2012: 90 days median2013: 88 days median2014: 124 days median2015: 102 days median2016: 121 days median2017: 67 days median2018: 95 days median2019: 81 days median2020: 55 days median2021: 59 days median2022: 85 days median2023: 59 days median2024: 64 days median2025: 64 days median2026 (partial year): 76 days median
2007high 124 (2014) · low 55 (2020)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KWQ

1in 2018

2007: 22008: 332009: 352010: 22011: 52012: 72013: 62015: 22016: 92017: 82018: 1
2007high 35 (2009) · low 0 (2014)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KWQ

248in 2025

2007: 2882008: 3482009: 3552010: 6912011: 4152012: 5442013: 7962014: 5462015: 5622016: 5022017: 4922018: 3412019: 2982020: 4002021: 5912022: 3922023: 3202024: 4192025: 248
2007high 796 (2013) · low 248 (2025)2025

MAUDE reports naming product code KWQ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007271012288
2008327033348
2009239035355
2010231042691
201122955415
201226907544
201322886796
2014171240546
2015251022562
2016151219502
201720678492
201822951341
201926810298
202026550400
202117590591
202218850392
202316590320
202417640419
20257640248
202610760—

What is it indicated for?

The Elegance® Anterior Cervical plate is intended for anterior fixation to the cervical spine from C2 to C7. The specific clinical indications include:

1. Degenerative disc disease (defined as back pain of discogenic origin with degenerative disc confirmed by patient history and radiographic studies)

2. Spondylolisthesis

3. Spinal stenosis

4. Deformities (i.e., scoliosis, kyphosis, and/or lordosis)

5. Pseudoarthrosis

6. Revision of previous surgery

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K243904: Elegance® Anterior Cervical plate.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K243904

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026