510(k) Report

510(k) · Cleared

Cleared

X-Wire Guidewire

K244061510(k) TraditionalCleared Aug 26, 2025238-day reviewClass II21 CFR 870.1330

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Imperative Care, Inc. · MOF Guide, Wire, Catheter, Neurovasculature

Cleared on Aug 26, 2025 as substantially equivalent to K231954 (Scientia Vascular, Inc., 2023) and 1 other predicate after a 238-day review. Its family tree reaches back 6 generations to 2000.

Decided
Aug 26, 2025
Review
238 days
Class
Class II
Product code
MOF
Recalls
None
Predicates
2

Its longest line of descent runs back 6 generations to K002212 (2000). 9 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 6 generations backK002212 Mirage Hydrophilic Guidewire, Model 103-0608Micro Therapeutics, Inc. · 2000
  2. 5 generations backK032146 PVS 1300 Synchro 0.014 & PVS 1600 Synchro 0.010 Guide WiresPrecision Vascular Systems, Inc. · 2003 · Recalled
  3. 4 generations backK173235 Aristotle 14 Guidewire, 200cm, Soft Profile, Aristotle 14 Guidewire…Scientia Vascular, LLC · 2018
  4. 3 generations backK183608 Aristotle 18 Guidewire, 200cm, Soft Profile ; Aristotle 18…Scientia Vascular, LLC · 2019
  5. 2 generations backK192783 Aristotle 24 Guidewire, 200cm, Soft Profile ; Aristotle 24…Scientia Vascular, LLC · 2019
  6. 1 generation backK220398 Aristotle 14 Guidewire; Aristotle 18 Guidewire; Aristotle 24…Scientia Vascular, LLC · 2023
  7. This deviceK244061 X-Wire GuidewireImperative Care, Inc. · 2025
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K002212Mirage Hydrophilic Guidewire, Model 103-0608Micro Therapeutics, Inc.2000—
−5K032146PVS 1300 Synchro 0.014 & PVS 1600 Synchro 0.010 Guide WiresPrecision Vascular Systems, Inc.20031
−4K173235Aristotle 14 Guidewire, 200cm, Soft Profile, Aristotle 14 Guidewire, 200cm…Scientia Vascular, LLC2018—
−3K183608Aristotle 18 Guidewire, 200cm, Soft Profile ; Aristotle 18 Guidewire, 200cm…Scientia Vascular, LLC2019—
−2K192783Aristotle 24 Guidewire, 200cm, Soft Profile ; Aristotle 24 Guidewire, 200cm…Scientia Vascular, LLC2019—
−1K220398Aristotle 14 Guidewire; Aristotle 18 Guidewire; Aristotle 24 Guidewire; Volo…Scientia Vascular, LLC2023—
0 (this device)K244061X-Wire GuidewireImperative Care, Inc.2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
201810
202010
202310
FIG. 1 — Lineage of K244061, 2000–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MOF? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MOF device

  1. #1 K253168 0.014” Willow Guidewirescore 17.9 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K231954Aristotle 18 Guidewire; Aristotle 24 Guidewire
Summary page 5
…ive Care, Inc. C. Predicate Devices: Proprietary Names: Aristotle 18 Guidewire; Aristotle 24 Guidewire (K231954) Aristotle 14 Guidewire (K220398) Common/Usual Name: Guidewire…
Scientia Vascular, Inc.2023—
*K220398Aristotle 14 Guidewire; Aristotle 18 Guidewire; Aristotle 24 Guidewire; Volo 14…
Summary page 5
…Aristotle 18 Guidewire; Aristotle 24 Guidewire (K231954) Aristotle 14 Guidewire (K220398) Common/Usual Name: Guidewire Classification Name: Catheter guide wire Product C…
Scientia Vascular, LLC2023—

Also cleared against K231954: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 25 years and passes through 4 companies; a new generation was cleared every 3.0 years on median.
  • 1 of the 9 ancestors has a recall of any class.
  • 2 other devices also cite its predicate K231954.

How does its category compare?

All MOF devices

MOF Guide, Wire, Catheter, Neurovasculature: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.

FDA decisions per year · MOF

11so far in 2026, the most since 2007

2011: 22014: 22015: 32016: 42017: 12018: 22019: 42020: 42022: 12023: 42024: 22025: 52026 (partial year): 11
2007high 11 (2026) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MOF

172in 2025

2015: 133 days median2016: 61 days median2019: 58 days median2020: 36 days median2023: 199 days median2025: 172 days median2026 (partial year): 192 days median
2007high 199 (2023) · low 36 (2020)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MOF

No recall names MOF since 2007.

Adverse event reports per year · MOF

135in 2025

2008: 12012: 22013: 22015: 52016: 32017: 152018: 112019: 122020: 182021: 392022: 922023: 912024: 952025: 135
2007high 135 (2025) · low 0 (2007)2025

MAUDE reports naming product code MOF, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—01
20090—00
20100—00
20112—00
20120—02
20130—02
20142—00
2015313305
201646103
20171—015
20182—011
2019458012
2020436018
20210—039
20221—092
20234199091
20242—095
202551720135
2026111920—

What is it indicated for?

The X-Wire Guidewire is indicated for general intravascular use within the peripheral and neuro vasculature to introduce and position catheters and other interventional devices. The guidewire is not intended for use in the coronary vasculature.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K244061: X-Wire Guidewire.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K244061

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026