510(k) Report

510(k) · Cleared

Cleared

Mfuse (MS001)

K250319510(k) TraditionalCleared Dec 15, 2025314-day reviewClass U

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Machina Medical, Inc. · QSY Hemostatic Wound Dressing Without Thrombin Or Other Biologics

Cleared on Dec 15, 2025 as substantially equivalent to K240713 (Cresilon, Inc., 2024) after a 314-day review. Its family tree reaches back 6 generations to 2000.

Decided
Dec 15, 2025
Review
314 days
Class
Class U
Product code
QSY
Recalls
None
Predicates
1

Its longest line of descent runs back 6 generations to K002550 (2000). 13 ancestors in all, the oldest K972914 (1997). No later device cites it as a predicate yet.

  1. Root · 6 generations backK002550 RDH BandageMarine Polymer Technologies, Inc. · 2000
  2. 5 generations backK013390 QuickclotOn Site Gas Systems, Inc. · 2002
  3. 4 generations backK061079 Medtrade Products Celox Topical Hemostatic Granules, Medtrade…Medtrade Products, Ltd. · 2006
  4. 3 generations backK080097 Medtrade Products Celox Hemostatic Granules on SheetMedtrade Products, Ltd. · 2008
  5. 2 generations backK113560 Celox Gauze ProMedtrade Products, Ltd. · 2012
  6. 1 generation backK240713 Traumagel®Cresilon, Inc. · 2024
  7. This deviceK250319 Mfuse (MS001)Machina Medical, Inc. · 2025
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K002550RDH BandageMarine Polymer Technologies, Inc.2000—
−5K013390QuickclotOn Site Gas Systems, Inc.2002—
−4K061079Medtrade Products Celox Topical Hemostatic Granules, Medtrade Products Celox…Medtrade Products, Ltd.2006—
−3K080097Medtrade Products Celox Hemostatic Granules on SheetMedtrade Products, Ltd.2008—
−2K113560Celox Gauze ProMedtrade Products, Ltd.2012—
−1K240713Traumagel®Cresilon, Inc.2024—
0 (this device)K250319Mfuse (MS001)Machina Medical, Inc.2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199710
199810
200220
200710
200910
201010
FIG. 1 — Lineage of K250319, 2000–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in QSY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new QSY device

  1. #1 K240713 Traumagel®score 15.0 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K240713Traumagel®
Summary page 5
…QSY Regulation Number: Not Applicable Predicate Devices: Primary TRAUMAGEL® (K240713) Device Description MFUSE™ is a sterile, single-use, disposable device designed to stop bleeding by creating an barrier over t…
Cresilon, Inc.2024—
†K061079Medtrade Products Celox Topical Hemostatic Granules, Medtrade Products Celox 762…Medtrade Products, Ltd.2006—

Also cleared against K240713: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 25 years and passes through 5 companies; a new generation was cleared every 4.0 years on median.
  • None of the 13 ancestors has a recall.
  • 1 other device also cites its predicate K240713.

How does its category compare?

All QSY devices

QSY Hemostatic Wound Dressing Without Thrombin Or Other Biologics: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.

FDA decisions per year · QSY

2in 2025

2007: 132008: 72009: 92010: 72011: 82012: 72013: 32014: 62015: 62016: 52017: 12018: 52019: 42020: 12021: 12022: 22023: 72024: 42025: 22026 (partial year): 2
2007high 13 (2007) · low 1 (2017)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · QSY

142in 2024

2007: 63 days median2008: 61 days median2009: 55 days median2010: 75 days median2011: 137 days median2012: 239 days median2013: 161 days median2014: 249 days median2015: 171 days median2016: 161 days median2018: 186 days median2019: 336 days median2023: 586 days median2024: 142 days median
2007high 586 (2023) · low 55 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · QSY

No recall names QSY since 2007.

Adverse event reports per year · QSY

14in 2025

2022: 12024: 32025: 14
2007high 14 (2025) · low 0 (2007)2025

MAUDE reports naming product code QSY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007136300
200876100
200995500
201077500
2011813700
2012723900
2013316100
2014624900
2015617100
2016516100
20171—00
2018518600
2019433600
20201—00
20211—00
20222—01
2023758600
2024414203
20252—014
20262—0—

What is it indicated for?

MFUSE™ is indicated for temporary external use for controlling moderate to severe bleeding.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K250319: Mfuse (MS001).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K250319

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026