510(k) Report

510(k) · Cleared

Cleared

Disposable Percutaneous Nephrostomy Dilatation Kit

K250448510(k) TraditionalCleared Jul 3, 2025135-day reviewClass U

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Shenzhen Trious Medical Technology Co., Ltd. · LJE Catheter, Nephrostomy

Cleared on Jul 3, 2025 as substantially equivalent to K170531 (Coloplast Corp., 2017) after a 135-day review. Its family tree reaches back 2 generations to 1996.

Decided
Jul 3, 2025
Review
135 days
Class
Class U
Product code
LJE
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K961904 (1996). No later device cites it as a predicate yet.

  1. Root · 2 generations backK961904 AQ Hydrophilic DilatorsCook Urological, Inc. · 1996
  2. 1 generation backK170531 Ureteral Dilators and Percutaneous Nephrostomy DilatorsColoplast Corp. · 2017 · Recalled
  3. This deviceK250448 Disposable Percutaneous Nephrostomy Dilatation KitShenzhen Trious Medical Technology Co., Ltd. · 2025
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K961904AQ Hydrophilic DilatorsCook Urological, Inc.1996—
−1K170531Ureteral Dilators and Percutaneous Nephrostomy DilatorsColoplast Corp.20171
0 (this device)K250448Disposable Percutaneous Nephrostomy Dilatation KitShenzhen Trious Medical Technology Co., Ltd.2025—
FIG. 1 — Lineage of K250448, 1996–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LJE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LJE device

  1. #1 K222705 Introducer Needlescore 5.7 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K170531Ureteral Dilators and Percutaneous Nephrostomy Dilators
Summary page 5
…Class: Class II Product code: EZN Review Panel: Gastroenterology/Urology III. Predicate Devices 510(k) Number: K170531 Trade name: Ureteral Dilators and Percutaneous Nephrostomy Dilators Common name: Ureteral Dilato…
Coloplast Corp.20171

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 29 years and passes through 3 companies; a new generation was cleared every 20.8 years on median.
  • 1 of the 2 ancestors has a recall of any class.

How does its category compare?

All LJE devices

LJE Catheter, Nephrostomy: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.

FDA decisions per year · LJE

1in 2025

2007: 12008: 12012: 12014: 12016: 12017: 12018: 32019: 42020: 22022: 12023: 12025: 1
2007high 4 (2019) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LJE

254in 2019

2018: 107 days median2019: 254 days median
2007high 254 (2019) · low 107 (2018)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LJE

1in 2025

2007: 12016: 12019: 12020: 22021: 12025: 1
2007high 2 (2020) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LJE

59in 2025

2007: 52008: 82009: 122010: 62011: 152012: 162013: 152014: 42015: 92016: 262017: 602018: 692019: 782020: 502021: 382022: 422023: 1312024: 472025: 59
2007high 131 (2023) · low 4 (2014)2025

MAUDE reports naming product code LJE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—15
20081—08
20090—012
20100—06
20110—015
20121—016
20130—015
20141—04
20150—09
20161—126
20171—060
20183107069
20194254178
20202—250
20210—138
20221—042
20231—0131
20240—047
20251—159
20260—0—

What is it indicated for?

Disposable Percutaneous Nephrostomy Dilators:

Dilator for tract preparation and splittable working sheath to protect the parenchyma.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K250448: Disposable Percutaneous Nephrostomy Dilatation Kit.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K250448

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026