510(k) · Cleared
ClearedLinkt Compression Staple System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Trax Surgical · JDR Staple, Fixation, Bone
Cleared on May 14, 2025 as substantially equivalent to K203832 (Wright Medical, 2021) and 2 other predicates after a 65-day review. Its family tree reaches back 6 generations to 1990.
- Decided
- May 14, 2025
- Review
- 65 days
- Class
- Class II
- Product code
- JDR
- Recalls
- None
- Predicates
- 3
Its longest line of descent runs back 6 generations to K902307 (1990). 8 ancestors in all. No later device cites it as a predicate yet.
- Root · 6 generations backK902307 Shaw II Hemostatic Surgery SystemHemostatic Surgery Corp. · 1990 · Recalled
- 5 generations backK993714 Memograph Staple, Warm SystemBiomedical Ent., Inc. · 2000
- 4 generations backK070031 Memometal Memory StaplesMemometal Technologies · 2007
- 3 generations backK124045 Fuseforce Implant SystemSolana Surgical, LLC · 2013
- 2 generations backK210482 Medline UNITE REFLEX Nitinol Staple SystemMedline Industries, Inc. · 2021
- 1 generation backK231885 Medline UNITE® REFLEX® Nitinol Staple SystemMedline Industries, LP · 2023
- This deviceK250712 Linkt Compression Staple SystemTrax Surgical · 2025
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −6 | K902307 | Shaw II Hemostatic Surgery System | Hemostatic Surgery Corp. | 1990 | 2 |
| −5 | K993714 | Memograph Staple, Warm System | Biomedical Ent., Inc. | 2000 | — |
| −4 | K070031 | Memometal Memory Staples | Memometal Technologies | 2007 | — |
| −3 | K124045 | Fuseforce Implant System | Solana Surgical, LLC | 2013 | — |
| −2 | K210482 | Medline UNITE REFLEX Nitinol Staple System | Medline Industries, Inc. | 2021 | — |
| −1 | K231885 | Medline UNITE® REFLEX® Nitinol Staple System | Medline Industries, LP | 2023 | — |
| 0 (this device) | K250712 | Linkt Compression Staple System | Trax Surgical | 2025 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1997 | 1 | 0 |
| 2021 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JDR? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JDR device
- #1 K243658 TMC Compression Implant Systemscore 16.7 · 18 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K203832 | FuseForce™ Flex Dynamic Compression SystemSummary page 5…Device Class: 2 Review Panel: Orthopedic Primary Predicate Device: Wright Medical FuseForce Flex Dynamic Compression System (K203832) Additional Predicate Devices: Medline Unite Reflex Nitinol Staple System (K210482)… | 2021 |
| * | K210482 | Medline UNITE REFLEX Nitinol Staple SystemSummary page 5…cate Device: Wright Medical FuseForce Flex Dynamic Compression System (K203832) Additional Predicate Devices: Medline Unite Reflex Nitinol Staple System (K210482) Medline Unite Reflex Nitinol Staple System (K231885) Device Description The Linkt Compr… | 2021 |
| * | K231885 | Medline UNITE® REFLEX® Nitinol Staple SystemSummary page 5…ional Predicate Devices: Medline Unite Reflex Nitinol Staple System (K210482) Medline Unite Reflex Nitinol Staple System (K231885) Device Description The Linkt Compression Staple System consists of individually packaged, sterile, bone staple implants and a… | 2023 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 35 years and passes through 7 companies; a new generation was cleared every 7.1 years on median.
- 2 of the 8 ancestors have a recall of any class.
- 1 other device also cites its predicate K203832.
How does its category compare?
All JDR devicesJDR Staple, Fixation, Bone: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.
FDA decisions per year · JDR
3in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · JDR
65in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JDR
11in 2022
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JDR
314in 2025
MAUDE reports naming product code JDR, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 8 | 70 | 0 | 3 |
| 2008 | 5 | 89 | 1 | 14 |
| 2009 | 0 | — | 0 | 10 |
| 2010 | 2 | — | 0 | 35 |
| 2011 | 1 | — | 0 | 62 |
| 2012 | 1 | — | 0 | 34 |
| 2013 | 9 | 137 | 0 | 27 |
| 2014 | 11 | 97 | 0 | 49 |
| 2015 | 7 | 111 | 1 | 48 |
| 2016 | 6 | 101 | 0 | 76 |
| 2017 | 9 | 172 | 0 | 116 |
| 2018 | 8 | 107 | 1 | 239 |
| 2019 | 5 | 149 | 0 | 242 |
| 2020 | 4 | 161 | 1 | 234 |
| 2021 | 3 | 62 | 0 | 210 |
| 2022 | 5 | 107 | 11 | 202 |
| 2023 | 9 | 72 | 0 | 175 |
| 2024 | 4 | 29 | 0 | 206 |
| 2025 | 3 | 65 | 0 | 314 |
| 2026 | 2 | — | 2 | — |
What is it indicated for?
The Linkt ™ Compression Staple System is intended to be used for fracture and osteotomy fixation and joint arthrodesis of the hand and foot.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K250712 · printed Nov 6, 2026
Cite this page
510(k) Report. “K250712: Linkt Compression Staple System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K250712
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026