510(k) · Cleared
ClearedWinForth (LM-E470KA)
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Shenzhen Leaflife Technology Co., Ltd. · PBX Massager, Vacuum, Radio Frequency Induced Heat
Cleared on Aug 14, 2025 after a 140-day review. FDA’s file for it is a 510(k) statement, which names no predicate.
- Decided
- Aug 14, 2025
- Review
- 140 days
- Class
- Class II
- Product code
- PBX
- Recalls
- None
- Predicates
- 0
FDA’s file for it is a 510(k) statement, which names no predicate.
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in PBX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new PBX device
- #1 K210877 Evolve System with the T3 Applicatorscore 23.6 · 24 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All PBX devicesPBX Massager, Vacuum, Radio Frequency Induced Heat: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.
FDA decisions per year · PBX
7in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · PBX
200in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · PBX
1in 2017
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · PBX
4in 2025
MAUDE reports naming product code PBX, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 0 |
| 2011 | 0 | — | 0 | 0 |
| 2012 | 1 | — | 0 | 0 |
| 2013 | 0 | — | 0 | 12 |
| 2014 | 2 | — | 0 | 4 |
| 2015 | 5 | 181 | 0 | 0 |
| 2016 | 7 | 130 | 0 | 2 |
| 2017 | 6 | 132 | 1 | 1 |
| 2018 | 3 | 89 | 0 | 1 |
| 2019 | 8 | 147 | 0 | 4 |
| 2020 | 8 | 134 | 0 | 4 |
| 2021 | 6 | 169 | 0 | 8 |
| 2022 | 7 | 308 | 0 | 7 |
| 2023 | 9 | 227 | 0 | 7 |
| 2024 | 6 | 130 | 0 | 2 |
| 2025 | 7 | 200 | 0 | 4 |
| 2026 | 6 | 225 | 0 | — |
What is it indicated for?
The WinForth is intended to provide topical heating for the purpose of elevating tissue temperature for the treatment of selected medical conditions such as relief of pain, muscle spasms, and increase in local circulation.
The WinForth massage device is intended to provide a temporary reduction in the appearance of cellulite.
Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K250916 · printed Nov 4, 2026
Cite this page
510(k) Report. “K250916: WinForth (LM-E470KA).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K250916
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026