510(k) · Cleared
ClearedThe Sensititre 18-24 hour MIC or Breakpoint Susceptibility System with Ciprofloxacin in the dilution range of 0.002-64 ug/mL
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Thermo Fisher Scientific · JWY Manual Antimicrobial Susceptibility Test Systems
Cleared on Jun 30, 2025 after a 91-day review. FDA’s file for it is a 510(k) statement, which names no predicate.
- Decided
- Jun 30, 2025
- Review
- 91 days
- Class
- Class II
- Product code
- JWY
- Recalls
- None
- Predicates
- 0
FDA’s file for it is a 510(k) statement, which names no predicate.
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JWY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JWY device
- #1 K260447 ETEST Gepotidacin (GEP) (0.016-256 µg/mL)score 12.7 · 6 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All JWY devicesJWY Manual Antimicrobial Susceptibility Test Systems: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.
FDA decisions per year · JWY
14in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · JWY
106in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JWY
31in 2022
Class I (13 since 2007) Class II/III not classified
Adverse event reports per year · JWY
1in 2024
MAUDE reports naming product code JWY, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 6 | 85 | 1 | 1 |
| 2009 | 2 | — | 0 | 1 |
| 2010 | 4 | 73 | 0 | 0 |
| 2011 | 4 | 125 | 3 | 0 |
| 2012 | 1 | — | 0 | 0 |
| 2013 | 0 | — | 0 | 0 |
| 2014 | 6 | 106 | 5 | 4 |
| 2015 | 9 | 90 | 6 (4) | 11 |
| 2016 | 4 | 88 | 0 | 20 |
| 2017 | 14 | 61 | 2 | 9 |
| 2018 | 12 | 51 | 0 | 13 |
| 2019 | 18 | 60 | 0 | 10 |
| 2020 | 5 | 66 | 0 | 20 |
| 2021 | 5 | 266 | 0 | 41 |
| 2022 | 0 | — | 31 (9) | 11 |
| 2023 | 7 | 85 | 0 | 9 |
| 2024 | 6 | 90 | 0 | 1 |
| 2025 | 14 | 106 | 0 | 0 |
| 2026 | 2 | — | 0 | — |
What is it indicated for?
The Sensititre 18-24 hour MIC or Breakpoint Susceptibility System is an in vitro diagnostic product for clinical susceptibility testing of non-fastidious isolates. This 510(k) is for ciprofloxacin in the dilution range of 0.002-64 µg/mL for testing non-fastidious gram-negative isolates on The Sensititre 18-24 hour MIC or Breakpoint Susceptibility System. Testing is indicated for Enterobacterales and Pseudomonas aeruginosa, as recognized by the FDA…
Read the full statement (122 words)
The Sensititre 18-24 hour MIC or Breakpoint Susceptibility System is an in vitro diagnostic product for clinical susceptibility testing of non-fastidious isolates.
This 510(k) is for ciprofloxacin in the dilution range of 0.002-64 µg/mL for testing non-fastidious gram-negative isolates on The Sensititre 18-24 hour MIC or Breakpoint Susceptibility System. Testing is indicated for Enterobacterales and Pseudomonas aeruginosa, as recognized by the FDA Susceptibility Test Interpretive Criteria (STIC) webpage.
The Sensititre 18-24 hour MIC or Breakpoint Susceptibility System with Ciprofloxacin in the dilution range of 0.002-64 µg/mL demonstrated acceptable performance with the following organisms:
Enterobacterales (C. freundii, C. koseri, E. cloacae complex, E. coli, K. aerogenes, K. oxytoca, K.pneumoniae, M. morganii, P. mirabilis, P. rettgeri, P. stuartii, P. vulgaris, S. marcescens)
Pseudomonas aeruginosa
Indications for use as stated in the FDA 510(k) statement.
https://510kreport.com/device/K250990 · printed Nov 4, 2026
Cite this page
510(k) Report. “K250990: The Sensititre 18-24 hour MIC or Breakpoint Susceptibility System with Ciprofloxacin in the dilution range of 0.002-64 ug/mL.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K250990
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026