510(k) Report

510(k) · Cleared

Cleared

Cary

K251111510(k) TraditionalCleared May 7, 202526-day reviewClass II21 CFR 878.4780

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Excitus AS · JCX Apparatus, Suction, Ward Use, Portable, Ac-Powered

Cleared on May 7, 2025 as substantially equivalent to K120065 (Plaxtron Industrial (M) Sdn. Bhd., 2012) after a 26-day review. Its family tree reaches back 3 generations to 1994.

Decided
May 7, 2025
Review
26 days
Class
Class II
Product code
JCX
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K935218 (1994). No later device cites it as a predicate yet.

  1. Root · 3 generations backK935218 Schuco-Vac Model 178Schuco, Inc. · 1994
  2. 2 generations backK982304 Devilbiss Suction UnitSunrise Medical Hhg, Inc. · 1998 · Recalled
  3. 1 generation backK120065 Plaxtron Suction Unit, Model 88AA51/88AA61 SeriesPlaxtron Industrial (M) Sdn. Bhd. · 2012 · Recalled
  4. This deviceK251111 CaryExcitus AS · 2025
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K935218Schuco-Vac Model 178Schuco, Inc.1994—
−2K982304Devilbiss Suction UnitSunrise Medical Hhg, Inc.19983
−1K120065Plaxtron Suction Unit, Model 88AA51/88AA61 SeriesPlaxtron Industrial (M) Sdn. Bhd.20123
0 (this device)K251111CaryExcitus AS2025—
FIG. 1 — Lineage of K251111, 1994–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JCX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JCX device

  1. #1 K250964 Protable Phlegm Suction Unit (JMA D01)score 12.2 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K120065Plaxtron Suction Unit, Model 88AA51/88AA61 Series
Summary page 5
…se, Portable, Ac-Powered Regulation Number: 878.4780 Product Code: JCX Legally Marketed Predicate Device Predicate: K120065 Predicate Trade Name: Laerdal Compact Suction Unit 4 (LCSU 4) Product Code: JCX Device Descriptio…
Plaxtron Industrial (M) Sdn. Bhd.20123

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 31 years and passes through 4 companies; a new generation was cleared every 13.1 years on median.
  • 2 of the 3 ancestors have a recall of any class.

How does its category compare?

All JCX devices

JCX Apparatus, Suction, Ward Use, Portable, Ac-Powered: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.

FDA decisions per year · JCX

2in 2025

2008: 42009: 12010: 12011: 22012: 22013: 52014: 42016: 22017: 22018: 22019: 32022: 12023: 12024: 12025: 22026 (partial year): 1
2007high 5 (2013) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JCX

30in 2019

2008: 43 days median2013: 144 days median2014: 106 days median2019: 30 days median
2007high 144 (2013) · low 30 (2019)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JCX

1in 2020

2008: 32011: 22013: 22017: 12020: 12026 (partial year): 1
2007high 3 (2008) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JCX

45in 2025

2007: 482008: 572009: 342010: 72011: 92012: 182013: 122014: 682015: 1182016: 1192017: 1022018: 1702019: 1322020: 892021: 2272022: 2152023: 1872024: 1032025: 45
2007high 227 (2021) · low 7 (2010)2025

MAUDE reports naming product code JCX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—048
2008443357
20091—034
20101—07
20112—29
20122—018
20135144212
20144106068
20150—0118
20162—0119
20172—1102
20182—0170
20193300132
20200—189
20210—0227
20221—0215
20231—0187
20241—0103
20252—045
20261—1—

What is it indicated for?

Cary is indicated for removal of fluids from the upper airway. The device creates a negative pressure (vacuum) that draws fluids through disposable suction tube that is connected to a disposable collection canister. The fluids are captured in the collection canister for proper disposal. Cary is for use only on the order of a physician or other licensed practitioner (e.g. Emergency Medical Technician in field use).

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K251111: Cary.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K251111

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026