510(k) Report

510(k) · Cleared

Cleared

Brain WMH

K251527510(k) TraditionalCleared Sep 25, 2025129-day reviewClass II21 CFR 892.2050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Quantib B.V. · QIH Automated Radiological Image Processing Software

Cleared on Sep 25, 2025 as substantially equivalent to K213737 (Quantib B.V., 2022) after a 129-day review. Its family tree reaches back 7 generations to 2001.

Decided
Sep 25, 2025
Review
129 days
Class
Class II
Product code
QIH
Recalls
None
Predicates
1

Its longest line of descent runs back 7 generations to K011196 (2001). No later device cites it as a predicate yet.

  1. Root · 7 generations backK011196 Iquantify, Version 1.0Insightful Corporation · 2001
  2. 6 generations backK050703 QbrainMedis Medical Imaging Systems BV · 2005
  3. 5 generations backK153351 Quantib Brain 1Quantib B.V. · 2016
  4. 4 generations backK163013 Quantib Brain 1.2Quantib B.V. · 2017
  5. 3 generations backK173939 Quantib BrainQuantib B.V. · 2018
  6. 2 generations backK182564 Quantib NDQuantib B.V. · 2018
  7. 1 generation backK213737 Quantib NDQuantib B.V. · 2022
  8. This deviceK251527 Brain WMHQuantib B.V. · 2025
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K011196Iquantify, Version 1.0Insightful Corporation2001—
−6K050703QbrainMedis Medical Imaging Systems BV2005—
−5K153351Quantib Brain 1Quantib B.V.2016—
−4K163013Quantib Brain 1.2Quantib B.V.2017—
−3K173939Quantib BrainQuantib B.V.2018—
−2K182564Quantib NDQuantib B.V.2018—
−1K213737Quantib NDQuantib B.V.2022—
0 (this device)K251527Brain WMHQuantib B.V.2025—
FIG. 1 — Lineage of K251527, 2001–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in QIH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new QIH device

  1. #1 K213998 cvi42 Auto Imaging Software Applicationscore 23.5 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K213737Quantib ND
Summary page 5
…sification Names: Medical image management and processing system (892.2050) Regulation Class: II Product Code: QIH 3. Predicate Device Trade Name of Device: Quantib ND (K213737) Common or Usual Name: Medical Image Software Classification Names: Medical image management and processing system (892.2050) Reg…
Quantib B.V.2022—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 24 years and passes through 3 companies; a new generation was cleared every 3.0 years on median.
  • None of the 7 ancestors has a recall.

How does its category compare?

All QIH devices

QIH Automated Radiological Image Processing Software: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.

FDA decisions per year · QIH

94in 2025

2019: 22020: 112021: 192022: 252023: 452024: 642025: 942026 (partial year): 78
2007high 94 (2025) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · QIH

150in 2025

2020: 145 days median2021: 125 days median2022: 134 days median2023: 151 days median2024: 141 days median2025: 150 days median2026 (partial year): 130 days median
2007high 151 (2023) · low 125 (2021)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · QIH

1so far in 2026, the most since 2007

2026 (partial year): 1
2007high 1 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · QIH

4in 2025

2024: 22025: 4
2007high 4 (2025) · low 0 (2007)2025

MAUDE reports naming product code QIH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—00
20192—00
20201114500
20211912500
20222513400
20234515100
20246414102
20259415004
2026781301—

What is it indicated for?

Intended Use Brain WMH is intended for automatic labeling, visualization, and volumetric quantification of WMH from T2w FLAIR MR images. The output consists of segmentations, visualizations and volumetric measurements of WMH. It is intended to provide the trained medical professional with complementary information for the evaluation and assessment of MR brain images and to aid the trained medical professional in quantitative reporting. Intended User…

Read the full statement (120 words)

Intended Use

Brain WMH is intended for automatic labeling, visualization, and volumetric quantification of WMH from T2w FLAIR MR images. The output consists of segmentations, visualizations and volumetric measurements of WMH. It is intended to provide the trained medical professional with complementary information for the evaluation and assessment of MR brain images and to aid the trained medical professional in quantitative reporting.

Intended User Population

The intended users of Brain WMH are trained medical professionals.

Intended Patient Population

Brain WMH is intended for post-processing of brain magnetic resonance imaging (MRI) data from patients 22 years of age or older, without pathologies (e.g. tumor or stroke), and treatment induced features (e.g. from prior surgery or radiation treatment), and without contrast enhancement.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K251527: Brain WMH.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K251527

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026