510(k) Report

510(k) · Cleared

Cleared

SteriHub™ Disinfecting Device and Protective Cover

K251592510(k) TraditionalCleared Feb 11, 2026264-day reviewClass II21 CFR 880.5440

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

1World Vista Medical · QBP Cap, Device Disinfectant

Cleared on Feb 11, 2026 as substantially equivalent to K193190 (Becton, Dickinson and Company, 2020) after a 264-day review. Its family tree reaches back 6 generations to 2003.

Decided
Feb 11, 2026
Review
264 days
Class
Class II
Product code
QBP
Recalls
None
Predicates
1

Its longest line of descent runs back 6 generations to K030467 (2003). 9 ancestors in all, the oldest K833182 (1983). No later device cites it as a predicate yet.

  1. Root · 6 generations backK030467 Gravitech TM Flow Controller Primary Set/Gravitech Flow Controller…Iv Medical, Inc. · 2003
  2. 5 generations backK063239 Lifeshield Latex-Free Gravitech Flow Controller I.V. Sets, Models…Hospira, Inc. · 2006 · Recalled
  3. 4 generations backK080579 Effectiv (TM) CapHospira, Inc. · 2008
  4. 3 generations backK083508 SwabcapExcelsior Medical Corp. · 2009
  5. 2 generations backK111992 Curos Port ProtectorIvera Medical, Inc. · 2012
  6. 1 generation backK193190 BD PureHub Disinfecting CapBecton, Dickinson and Company · 2020
  7. This deviceK251592 SteriHub™ Disinfecting Device and Protective Cover1World Vista Medical · 2026
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K030467Gravitech TM Flow Controller Primary Set/Gravitech Flow Controller Extension SetIv Medical, Inc.2003—
−5K063239Lifeshield Latex-Free Gravitech Flow Controller I.V. Sets, Models 17528…Hospira, Inc.20067
−4K080579Effectiv (TM) CapHospira, Inc.2008—
−3K083508SwabcapExcelsior Medical Corp.2009—
−2K111992Curos Port ProtectorIvera Medical, Inc.2012—
−1K193190BD PureHub Disinfecting CapBecton, Dickinson and Company2020—
0 (this device)K251592SteriHub™ Disinfecting Device and Protective Cover1World Vista Medical2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198310
200810
201110
FIG. 1 — Lineage of K251592, 2003–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in QBP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new QBP device

  1. #1 K252006 OTTO™ Disinfecting Capscore 12.3 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K193190BD PureHub Disinfecting Cap
Summary page 5
…ion Name: Intravascular Administration Set Common/Usual Name: Device Disinfectant Cap Regulatory Class: Class II Product Code: QBP 510K Number: K193190 1 4. REFERENCE DEVICE INFORMATION…
Becton, Dickinson and Company2020—
†K112791Sitescrub Ipa DeviceC. R. Bard2012—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 23 years and passes through 6 companies; a new generation was cleared every 3.7 years on median.
  • 1 of the 9 ancestors has a recall of any class.

How does its category compare?

All QBP devices

QBP Cap, Device Disinfectant: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.

FDA decisions per year · QBP

1in 2024

2008: 22009: 12010: 12011: 22012: 42013: 22014: 22015: 12020: 42024: 12026 (partial year): 2
2007high 4 (2012) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · QBP

299in 2020

2012: 129 days median2020: 299 days median
2007high 299 (2020) · low 129 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · QBP

No recall names QBP since 2007.

Adverse event reports per year · QBP

14in 2025

2019: 32021: 12023: 12024: 12025: 14
2007high 14 (2025) · low 0 (2007)2025

MAUDE reports naming product code QBP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20082—00
20091—00
20101—00
20112—00
2012412900
20132—00
20142—00
20151—00
20160—00
20170—00
20180—00
20190—03
2020429900
20210—01
20220—00
20230—01
20241—01
20250—014
20262—0—

What is it indicated for?

The SteriHub TM Disinf ecting Device and Protective Cover is intended for active disinfection of needleless

connectors.

The SteriHub Disinf ecting Device and Protective Cover provides a physical barrier to contamination for up

to 7 days, if not removed. The SteriHub may be used in the home or healthcare facility.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K251592: SteriHub™ Disinfecting Device and Protective Cover.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K251592

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026