510(k) · Cleared
ClearedStrauss Surgical Cystoscopes & Hysteroscopes (STS-2040-302ASA HD-endoscope, STS-2040-302AA HD-endoscope, STS-2040-302BA HD-endoscope, STS-2040-302BSA HD-endoscope, STS-2040-302ESA HD-endoscope, STS-2040-302CA HD-endoscope, STS-2029-302AA HD-endoscope, STS-2029-302BA HD-endoscope, STS-2040-298DSA-RWF-endoscope, STS-2040-298ASA-RWF-endoscope, STS-2040-300GSA-RWF-endoscope, STS-2040-303CA-RWF-endoscope, STS-2040-280ASA-OLY-endoscope, STS-2040-280ESA-OLY-endoscope, STS-2040-283BSA-OLY-endo
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
American Medical Endoscopy, Inc. · FAJ Cystoscope And Accessories, Flexible/Rigid
Cleared on Aug 1, 2025 as substantially equivalent to K150158 (Schoelly Fiberoptic GmbH, 2015) after a 64-day review. Its family tree reaches back 5 generations to 1977. 1 later device descends from it.
- Decided
- Aug 1, 2025
- Review
- 64 days
- Class
- Class II
- Product code
- FAJ
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 5 generations to K770378 (1977). 14 ancestors in all. 1 later device descends from it, 1 citing it directly.
- Root · 5 generations backK770378 Laparoscope, Fiber Light, Palmer-JacobsRichard Wolf Medical Instruments Corp. · 1977
- 4 generations backK962256 Galileo Hysteroscopes and LaparoscopesGalileo Electro-Optics Corp. · 1996
- 3 generations backK031974 Asap Hysteroscope and Gynecologic Laparoscope (Surgery) 10-00018-00…Asap Endoscopic Products GmbH · 2003
- 2 generations backK060899 Flexilux II Cystoscope and HysteroscopeSchoelly Imaging, Inc. · 2007
- 1 generation backK150158 Schoelly Cystoscopes/Hysteroscopes and AccessoriesSchoelly Fiberoptic GmbH · 2015 · Recalled
- This deviceK251652 Strauss Surgical Cystoscopes & Hysteroscopes (STS-2040-302ASA…American Medical Endoscopy, Inc. · 2025
- Descendant · cites it directly · 0 of its ownK253892 Strauss Surgical Cystoscopes & Hysteroscopes (STS-2040-302ASA…Strauss Surgical USA · 2026
Most influential descendants
Showing 1 of 1 · See all- K253892Strauss Surgical Cystoscopes & Hysteroscopes (STS-2040-302ASA HD-endoscope, 4 x 302 mm…Strauss Surgical USA · 2026 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −5 | K770378 | Laparoscope, Fiber Light, Palmer-Jacobs | Richard Wolf Medical Instruments Corp. | 1977 | — |
| −4 | K962256 | Galileo Hysteroscopes and Laparoscopes | Galileo Electro-Optics Corp. | 1996 | — |
| −3 | K031974 | Asap Hysteroscope and Gynecologic Laparoscope (Surgery) 10-00018-00… | Asap Endoscopic Products GmbH | 2003 | — |
| −2 | K060899 | Flexilux II Cystoscope and Hysteroscope | Schoelly Imaging, Inc. | 2007 | — |
| −1 | K150158 | Schoelly Cystoscopes/Hysteroscopes and Accessories | Schoelly Fiberoptic GmbH | 2015 | 1 |
| 0 (this device) | K251652 | Strauss Surgical Cystoscopes & Hysteroscopes (STS-2040-302ASA HD-endoscope… | American Medical Endoscopy, Inc. | 2025 | — |
| +1 | K253892 | Strauss Surgical Cystoscopes & Hysteroscopes (STS-2040-302ASA HD-endoscope, 4… | Strauss Surgical USA | 2026 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1988 | 1 | 0 |
| 1994 | 1 | 0 |
| 1996 | 1 | 0 |
| 1999 | 4 | 0 |
| 2003 | 1 | 0 |
| 2004 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2026 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FAJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FAJ device
- #1 K193095 Ambu aScope 4 Cystoscore 31.5 · 9 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K150158 | Schoelly Cystoscopes/Hysteroscopes and AccessoriesSummary page 5…1500 Product Code(s) FAJ, HIH | Legally Marketed Predicate Devices 21 CFR 807.92(a)(3) Predicate # Predicate Trade Name (Primary Predicate is listed first) Product Code K150158 Schoelly Cystoscopes/Hysteroscopes and accessories FAJ | Device Description Summary 21 CFR 807.92(a)(4) K251652,… | 2015 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K253892 | Strauss Surgical Cystoscopes & Hysteroscopes (STS-2040-302ASA HD-endoscope, 4 x 302 mm… | 2026 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 48 years and passes through 6 companies; a new generation was cleared every 8.0 years on median.
- 2 of the 14 ancestors have a recall of any class.
- Of its descendants, K253892 (Strauss Surgical USA, 2026) has gone furthest, with 0 descendants of its own.
- 4 other devices also cite its predicate K150158.
How does its category compare?
All FAJ devicesFAJ Cystoscope And Accessories, Flexible/Rigid: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.
FDA decisions per year · FAJ
8in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FAJ
98in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FAJ
7in 2023
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · FAJ
2,690in 2025
MAUDE reports naming product code FAJ, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 0 | 9 |
| 2008 | 0 | — | 0 | 10 |
| 2009 | 2 | — | 0 | 10 |
| 2010 | 1 | — | 0 | 9 |
| 2011 | 0 | — | 0 | 13 |
| 2012 | 1 | — | 0 | 8 |
| 2013 | 0 | — | 0 | 12 |
| 2014 | 1 | — | 0 | 6 |
| 2015 | 0 | — | 0 | 28 |
| 2016 | 1 | — | 0 | 75 |
| 2017 | 2 | — | 1 | 79 |
| 2018 | 2 | — | 0 | 79 |
| 2019 | 3 | 207 | 0 | 102 |
| 2020 | 2 | — | 0 | 339 |
| 2021 | 3 | 127 | 0 | 494 |
| 2022 | 5 | 170 | 1 | 744 |
| 2023 | 5 | 207 | 7 | 920 |
| 2024 | 9 | 130 | 0 | 892 |
| 2025 | 8 | 98 | 0 | 2,690 |
| 2026 | 5 | 123 | 0 | — |
What is it indicated for?
Strauss Surgical Cystoscopes are intended to illuminate and visualize the male urethra, prostate, and bladder for the purpose of performing diagnostic and surgical procedures.
Strauss Surgical Hysteroscopes are intended to illuminate and visualize the cervical canal and uterine cavity for the purpose of performing diagnostic and surgical procedures.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K251652 · printed Nov 4, 2026
Cite this page
510(k) Report. “K251652: Strauss Surgical Cystoscopes & Hysteroscopes (STS-2040-302ASA HD-endoscope, STS-2040-302AA HD-endoscope, STS-2040-302BA HD-endoscope, STS-2040-302BSA HD-endoscope, STS-2040-302ESA HD-endoscope, STS-2040-302CA HD-endoscope, STS-2029-302AA HD-endoscope, STS-2029-302BA HD-endoscope, STS-2040-298DSA-RWF-endoscope, STS-2040-298ASA-RWF-endoscope, STS-2040-300GSA-RWF-endoscope, STS-2040-303CA-RWF-endoscope, STS-2040-280ASA-OLY-endoscope, STS-2040-280ESA-OLY-endoscope, STS-2040-283BSA-OLY-endo.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K251652
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026