510(k) Report

510(k) · Cleared

Cleared

Biograph Vision PET/CT Systems; Biograph mCT PET/CT Systems

K251671510(k) SpecialCleared Jul 3, 202534-day reviewClass II21 CFR 892.1200

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Siemens Medical Solutions USA, Inc. · KPS System, Tomography, Computed, Emission

Cleared on Jul 3, 2025 as substantially equivalent to K193248 (Siemens Medical Solutions USA, Inc., 2020) after a 34-day review. Its family tree reaches back 17 generations to 2000.

Decided
Jul 3, 2025
Review
34 days
Class
Class II
Product code
KPS
Recalls
None
Predicates
1

Its longest line of descent runs back 17 generations to K002715 (2000). 23 ancestors in all, the oldest K843696 (1985). No later device cites it as a predicate yet.

Other ancestors, by year cleared 2004: 2 other ancestors2001: 1 other ancestor1998: 1 other ancestor1985: 2 other ancestorsReference device: K231833 · Biograph Vision.X and Biograph Vision.X Edge · Siemens Medical Solutions USA, Inc. · 2023Reference device: K223547 · Biograph Vision Quadra PET/CT System · Siemens Medical Solutions USA, Inc. · 2022Reference device: K230421 · SOMATOM Edge Plus, SOMATOM Confidence, SOMATOM Definition Edge, SOMATOM Definition AS/AS+, SOMATOM Definition AS Open, SOMATOM Drive, SOMATOM Force, SOMATOM Definition Flash · Siemens Medical Solutions USA, Inc. · 2023K002715 · Ecat Pet Scanner · Cti Pet Systems, Inc. · 2000 · recalledK013504 · Modification to: Ecat Lso Pet/CT Scanner · Cti Pet Systems, Inc. · 2001 · recalledK023518 · Ecat Lso Pet/CT 16 · Cti Pet Systems, Inc. · 2002 · recalledK033431 · Lso Pet/CT Hirez and Lso Pet/CT 16 Hirez · Cti Pet Systems, Inc. · 2003 · recalledK042467 · Lso Pet/CT Hirez 64 · Cti Pet Systems, Inc. · 2004 · recalledK050509 · Lso Pet/CT Hirez Series, Models 2I, 6I, 16I, 64I · Cti Pet Systems, Inc. · 2005×2: 2 generations cleared close together, K060060 (2006), K060631 (2006) K081453 · Biograph HD Family · Siemens Medical Solutions USA, Inc. · 2008K101550 · Biograph MCT Family · Siemens Medical Solutions USA, Inc. · 2010K113448 · Biograph MCT Family · Siemens Medical Solutions USA, Inc. · 2011K123737 · Biograph MCT Family · Siemens Medical Solutions USA, Inc. · 2013 · recalledK151486 · Biograph mCT and mCT Flow PET/CT Scanners · Siemens Medical Solutions USA, Inc. · 2015 · recalled×2: 2 generations cleared close together, K173578 (2017), K180811 (2018) K190900 · Biograph Vision · Siemens Medical Solutions USA, Inc. · 2019K193248 · Biograph Vision, Biograph mCT Family of PET/CTs · Siemens Medical Solutions USA, Inc. · 2020 · recalled1990200020102020
Other ancestors, by generation 9 generations back: 1 other ancestor10 generations back: 1 other ancestor11 generations back: 2 other ancestors12 generations back: 2 other ancestors K193248 · Biograph Vision, Biograph mCT Family of PET/CTs · Siemens Medical Solutions USA, Inc. · 2020 · recalledK190900 · Biograph Vision · Siemens Medical Solutions USA, Inc. · 2019K180811 · Biograph Vision · Siemens Medical Solutions USA, Inc. · 2018K173578 · Biograph mCT Family of PET/CT Systems · Siemens Medical Solutions USA, Inc. · 2017 · recalledK151486 · Biograph mCT and mCT Flow PET/CT Scanners · Siemens Medical Solutions USA, Inc. · 2015 · recalledK123737 · Biograph MCT Family · Siemens Medical Solutions USA, Inc. · 2013 · recalledK113448 · Biograph MCT Family · Siemens Medical Solutions USA, Inc. · 2011K101550 · Biograph MCT Family · Siemens Medical Solutions USA, Inc. · 2010K081453 · Biograph HD Family · Siemens Medical Solutions USA, Inc. · 2008K060631 · Biograph 64 and Biograph 40 · Siemens Medical Solutions USA, Inc. · 2006 · recalledK060060 · Biograph 6 · Siemens Medical Solutions USA, Inc. · 2006K050509 · Lso Pet/CT Hirez Series, Models 2I, 6I, 16I, 64I · Cti Pet Systems, Inc. · 2005K042467 · Lso Pet/CT Hirez 64 · Cti Pet Systems, Inc. · 2004 · recalledK033431 · Lso Pet/CT Hirez and Lso Pet/CT 16 Hirez · Cti Pet Systems, Inc. · 2003 · recalledK023518 · Ecat Lso Pet/CT 16 · Cti Pet Systems, Inc. · 2002 · recalledK013504 · Modification to: Ecat Lso Pet/CT Scanner · Cti Pet Systems, Inc. · 2001 · recalledK002715 · Ecat Pet Scanner · Cti Pet Systems, Inc. · 2000 · recalled−15−10−50
  1. Root · 17 generations backK002715 Ecat Pet ScannerCti Pet Systems, Inc. · 2000 · Recalled
  2. 13 generations between
  3. 3 generations backK180811 Biograph VisionSiemens Medical Solutions USA, Inc. · 2018
  4. 2 generations backK190900 Biograph VisionSiemens Medical Solutions USA, Inc. · 2019
  5. 1 generation backK193248 Biograph Vision, Biograph mCT Family of PET/CTsSiemens Medical Solutions USA, Inc. · 2020 · Recalled
  6. This deviceK251671 Biograph Vision PET/CT Systems; Biograph mCT PET/CT SystemsSiemens Medical Solutions USA, Inc. · 2025
Show all 17 generations
  1. Root · 17 generations backK002715 Ecat Pet ScannerCti Pet Systems, Inc. · 2000 · Recalled
  2. 16 generations backK013504 Modification to: Ecat Lso Pet/CT ScannerCti Pet Systems, Inc. · 2001 · Recalled
  3. 15 generations backK023518 Ecat Lso Pet/CT 16Cti Pet Systems, Inc. · 2002 · Recalled
  4. 14 generations backK033431 Lso Pet/CT Hirez and Lso Pet/CT 16 HirezCti Pet Systems, Inc. · 2003 · Recalled
  5. 13 generations backK042467 Lso Pet/CT Hirez 64Cti Pet Systems, Inc. · 2004 · Recalled
  6. 12 generations backK050509 Lso Pet/CT Hirez Series, Models 2I, 6I, 16I, 64ICti Pet Systems, Inc. · 2005
  7. 11 generations backK060060 Biograph 6Siemens Medical Solutions USA, Inc. · 2006
  8. 10 generations backK060631 Biograph 64 and Biograph 40Siemens Medical Solutions USA, Inc. · 2006 · Recalled
  9. 9 generations backK081453 Biograph HD FamilySiemens Medical Solutions USA, Inc. · 2008
  10. 8 generations backK101550 Biograph MCT FamilySiemens Medical Solutions USA, Inc. · 2010
  11. 7 generations backK113448 Biograph MCT FamilySiemens Medical Solutions USA, Inc. · 2011
  12. 6 generations backK123737 Biograph MCT FamilySiemens Medical Solutions USA, Inc. · 2013 · Recalled
  13. 5 generations backK151486 Biograph mCT and mCT Flow PET/CT ScannersSiemens Medical Solutions USA, Inc. · 2015 · Recalled
  14. 4 generations backK173578 Biograph mCT Family of PET/CT SystemsSiemens Medical Solutions USA, Inc. · 2017 · Recalled
  15. 3 generations backK180811 Biograph VisionSiemens Medical Solutions USA, Inc. · 2018
  16. 2 generations backK190900 Biograph VisionSiemens Medical Solutions USA, Inc. · 2019
  17. 1 generation backK193248 Biograph Vision, Biograph mCT Family of PET/CTsSiemens Medical Solutions USA, Inc. · 2020 · Recalled
  18. This deviceK251671 Biograph Vision PET/CT Systems; Biograph mCT PET/CT SystemsSiemens Medical Solutions USA, Inc. · 2025
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−17K002715Ecat Pet ScannerCti Pet Systems, Inc.20002
−16K013504Modification to: Ecat Lso Pet/CT ScannerCti Pet Systems, Inc.20012
−15K023518Ecat Lso Pet/CT 16Cti Pet Systems, Inc.20021
−14K033431Lso Pet/CT Hirez and Lso Pet/CT 16 HirezCti Pet Systems, Inc.20031
−13K042467Lso Pet/CT Hirez 64Cti Pet Systems, Inc.20041
−12K050509Lso Pet/CT Hirez Series, Models 2I, 6I, 16I, 64ICti Pet Systems, Inc.2005—
−11K060060Biograph 6Siemens Medical Solutions USA, Inc.2006—
−10K060631Biograph 64 and Biograph 40Siemens Medical Solutions USA, Inc.20063
−9K081453Biograph HD FamilySiemens Medical Solutions USA, Inc.2008—
−8K101550Biograph MCT FamilySiemens Medical Solutions USA, Inc.2010—
−7K113448Biograph MCT FamilySiemens Medical Solutions USA, Inc.2011—
−6K123737Biograph MCT FamilySiemens Medical Solutions USA, Inc.201317
−5K151486Biograph mCT and mCT Flow PET/CT ScannersSiemens Medical Solutions USA, Inc.201511
−4K173578Biograph mCT Family of PET/CT SystemsSiemens Medical Solutions USA, Inc.20172
−3K180811Biograph VisionSiemens Medical Solutions USA, Inc.2018—
−2K190900Biograph VisionSiemens Medical Solutions USA, Inc.2019—
−1K193248Biograph Vision, Biograph mCT Family of PET/CTsSiemens Medical Solutions USA, Inc.20202
0 (this device)K251671Biograph Vision PET/CT Systems; Biograph mCT PET/CT SystemsSiemens Medical Solutions USA, Inc.2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198520
199810
200110
200420
FIG. 1 — Lineage of K251671, 2000–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KPS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KPS device

  1. #1 K253564 uMI Panvivo (uMI Panvivo); uMI Panvivo (uMI…score 18.7 · 17 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K193248Biograph Vision, Biograph mCT Family of PET/CTs
Summary page 6
…1 3. Predicate Devices Primary Predicate Device: Product Trade Name: Biograph Vision and Biograph mCT PET/CT Systems 510(k) Number K193248 Clearance Date 02/14/2020 Common Name: Emission computed tomography system (PET)…
Siemens Medical Solutions USA, Inc.20202
†K231833Biograph Vision.X and Biograph Vision.X EdgeSiemens Medical Solutions USA, Inc.2023—
†K223547Biograph Vision Quadra PET/CT SystemSiemens Medical Solutions USA, Inc.2022—
†K230421SOMATOM Edge Plus, SOMATOM Confidence, SOMATOM Definition Edge, SOMATOM Definition…Siemens Medical Solutions USA, Inc.2023—

Also cleared against K193248: 3 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 25 years and passes through 2 companies; a new generation was cleared every 1.0 years on median.
  • 12 of the 23 ancestors have a recall of any class.
  • 3 other devices also cite its predicate K193248.

How does its category compare?

All KPS devices

KPS System, Tomography, Computed, Emission: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.

FDA decisions per year · KPS

12in 2025

2007: 82008: 172009: 92010: 32011: 72012: 62013: 112014: 112015: 32016: 112017: 112018: 132019: 32020: 122021: 152022: 52023: 122024: 112025: 122026 (partial year): 6
2007high 17 (2008) · low 3 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KPS

65in 2025

2007: 38 days median2008: 25 days median2009: 42 days median2010: 91 days median2011: 28 days median2012: 94 days median2013: 84 days median2014: 92 days median2015: 112 days median2016: 65 days median2017: 104 days median2018: 59 days median2019: 60 days median2020: 72 days median2021: 66 days median2022: 60 days median2023: 63 days median2024: 59 days median2025: 65 days median2026 (partial year): 67 days median
2007high 112 (2015) · low 25 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KPS

16in 2025

2007: 222008: 162009: 142010: 42011: 342012: 132013: 132014: 182015: 52016: 162017: 112018: 12, 3 Class I2019: 5, 5 Class I2020: 82021: 42022: 8, 6 Class I2023: 6, 3 Class I2024: 152025: 162026 (partial year): 6
2007high 34 (2011) · low 4 (2010)2026

Class I (17 since 2007) Class II/III not classified

Adverse event reports per year · KPS

36in 2025

2007: 382008: 112009: 152010: 442011: 562012: 342013: 2402014: 332015: 242016: 102017: 312018: 262019: 1052020: 222021: 102022: 152023: 222024: 232025: 36
2007high 240 (2013) · low 10 (2016)2025

MAUDE reports naming product code KPS, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20078382238
200817251611
20099421415
2010391444
20117283456
20126941334
2013118413240
201411921833
20153112524
201611651610
2017111041131
2018135912 (3)26
20193605 (5)105
20201272822
20211566410
20225608 (6)15
202312636 (3)22
202411591523
202512651636
20266676—

What is it indicated for?

The Siemens Biograph systems are combined X-Ray Computed Tomography (CT) and Positron Emission Tomography (PET) scanners that provide registration and fusion of high resolution physiologic and anatomic information. The CT component produces cross-sectional images of the body by computer reconstruction of X-Ray transmission data from either the same axial plane taken at different angles or spiral planes taken at different angles. The PET subsystem images…

Read the full statement (254 words)

The Siemens Biograph systems are combined X-Ray Computed Tomography (CT) and Positron Emission Tomography (PET) scanners that provide registration and fusion of high resolution physiologic and anatomic information.

The CT component produces cross-sectional images of the body by computer reconstruction of X-Ray transmission data from either the same axial plane taken at different angles or spiral planes taken at different angles. The PET subsystem images and measures the distribution of PET radiopharmaceuticals in humans for the purpose of determining various metabolic (molecular) and physiologic functions within the human body and utilizes the CT for fast attenuation correction maps for PEl studies and precise anatomical reference for the fused PET and CT images.

The system maintains independent functionality of the CT and PET devices, allowing for single modality CT and/or PET diagnostic imaging.

These systems are intended to be utilized by appropriately trained health care professionals to aid in detecting, localizing, diagnosing, staging, and restaging of lesions, tumors, disease, and organ function for the evaluation of diseases and disorders such as, but not limited to, cardiovascular disease, neurological disorders, and cancer. The images produced by the system can also be used by the physician to aid in radiotherapy treatment planning and interventional radiology procedures.

This CT system can be used for low dose lung cancer screening in high risk populations. *

* As defined by professional medical societies. Please refer to clinical literature, including the results of the National Lung Screening Trial (N Engl J Med 2011; 365; 395-409) and subsequent literature, for further information.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K251671: Biograph Vision PET/CT Systems; Biograph mCT PET/CT Systems.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K251671

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026