510(k) · Cleared
ClearedCURIS II RF Generator (REF 360100-05)
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Sutter Medizintechnik GmbH · GEI Electrosurgical, Cutting & Coagulation & Accessories
Cleared on Feb 11, 2026 as substantially equivalent to K171869 (Sutter Medizintechnik GmbH, 2018) after a 243-day review. Its family tree reaches back 5 generations to 1994.
- Decided
- Feb 11, 2026
- Review
- 243 days
- Class
- Class II
- Product code
- GEI
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 5 generations to K933157 (1994). 6 ancestors in all. No later device cites it as a predicate yet.
- Root · 5 generations backK933157 Erbotom Icc 200Erbe USA, Inc. · 1994
- 4 generations backK013255 Surgitron 120 Iec (Also Known as Surgitron 4.0 Dual RFEllman Intl., Inc. · 2001
- 3 generations backK061174 Surgi-MaxEllman Int'L, Inc. · 2006
- 2 generations backK100390 Surgimax/ Surgimax PlusElliquence, LLC · 2010
- 1 generation backK171869 Sutter CURIS RF GeneratorSutter Medizintechnik GmbH · 2018
- This deviceK251813 CURIS II RF Generator (REF 360100-05)Sutter Medizintechnik GmbH · 2026
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −5 | K933157 | Erbotom Icc 200 | Erbe USA, Inc. | 1994 | — |
| −4 | K013255 | Surgitron 120 Iec (Also Known as Surgitron 4.0 Dual RF | Ellman Intl., Inc. | 2001 | — |
| −3 | K061174 | Surgi-Max | Ellman Int'L, Inc. | 2006 | — |
| −2 | K100390 | Surgimax/ Surgimax Plus | Elliquence, LLC | 2010 | — |
| −1 | K171869 | Sutter CURIS RF Generator | Sutter Medizintechnik GmbH | 2018 | — |
| 0 (this device) | K251813 | CURIS II RF Generator (REF 360100-05) | Sutter Medizintechnik GmbH | 2026 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2000 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in GEI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new GEI device
- #1 K231790 The InMode System with the Morpheus8 Applicatorsscore 32.7 · 21 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K171869 | Sutter CURIS RF GeneratorSummary page 6…el: General & Plastic Surgery Regulatory Class: II Product Code: GEI 510k #: K2518113 IV PREDICATE DEVICE K171869 – Sutter CURIS® RF Generator V. DEVICE DESCRIPTION The Sutter CURIS® II RF Generator is a compact source of high radiofrequen… | 2018 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 32 years and passes through 5 companies; a new generation was cleared every 7.5 years on median.
- None of the 6 ancestors has a recall.
How does its category compare?
All GEI devicesGEI Electrosurgical, Cutting & Coagulation & Accessories: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.
FDA decisions per year · GEI
52in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · GEI
113in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · GEI
4in 2025
Class I (14 since 2007) Class II/III not classified
Adverse event reports per year · GEI
7,592in 2025
MAUDE reports naming product code GEI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 50 | 51 | 21 | 2,795 |
| 2008 | 61 | 71 | 19 | 2,556 |
| 2009 | 42 | 130 | 27 | 3,591 |
| 2010 | 46 | 109 | 51 | 3,377 |
| 2011 | 35 | 135 | 32 | 4,463 |
| 2012 | 39 | 133 | 30 | 5,216 |
| 2013 | 48 | 136 | 13 | 4,897 |
| 2014 | 49 | 103 | 3 | 4,908 |
| 2015 | 47 | 123 | 4 | 4,936 |
| 2016 | 64 | 108 | 3 | 5,616 |
| 2017 | 52 | 72 | 2 | 6,073 |
| 2018 | 47 | 93 | 6 | 6,545 |
| 2019 | 48 | 93 | 5 | 7,067 |
| 2020 | 59 | 105 | 1 | 6,490 |
| 2021 | 46 | 146 | 6 | 6,354 |
| 2022 | 55 | 150 | 49 | 6,103 |
| 2023 | 65 | 104 | 27 (4) | 7,176 |
| 2024 | 59 | 125 | 22 (10) | 7,897 |
| 2025 | 52 | 113 | 4 | 7,592 |
| 2026 | 43 | 183 | 8 | — |
What is it indicated for?
The Sutter Sutter CURIS® II RF Generator is intended for: Orthopedic, arthroscopic, spinal and neurosurgical: For resection and coagulation of soft tissues and hemostasis of blood vessels in orthopedic, arthroscopic, spinal and neurosurgical procedures. For soft tissue resection and coagulation during arthroscopic surgical procedures of knee, shoulder, ankle, elbow, hip and wrist. Cutting: Snoring, submucosal palatal shrinkage, traditional…
Read the full statement (164 words)
The Sutter Sutter CURIS® II RF Generator is intended for:
Orthopedic, arthroscopic, spinal and neurosurgical:
For resection and coagulation of soft tissues and hemostasis of blood vessels in orthopedic, arthroscopic, spinal and neurosurgical procedures.
For soft tissue resection and coagulation during arthroscopic surgical procedures of knee, shoulder, ankle, elbow, hip and wrist.
Cutting:
Snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment and turbinate shrinkage, skin incisions, biopsy, cysts, abscesses, tumors, cosmetic repairs, development of skin flaps, skin tags, blepharoplasty.
Blended Cutting and Coagulation:
Snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment and turbinate shrinkage, skin tags, papilloma keloids, keratosis, verrucae, basal cell carcinoma, nevi, fistulas, epithelioma, cosmetic repairs, cysts, abscesses, development of skin flaps.
Hemostasis and nonablative Coagulation:
Control of bleeding, epilation, teleangiectasia.
Bipolar:
Pinpoint, precise coagulation, pinpoint hemostasis in any field (wet or dry), snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment and turbinate shrinkage.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K251813 · printed Nov 6, 2026
Cite this page
510(k) Report. “K251813: CURIS II RF Generator (REF 360100-05).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K251813
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026