510(k) Report

510(k) · Cleared

Cleared

Bontree Plus

K251818510(k) TraditionalCleared Mar 6, 2026266-day reviewClass II21 CFR 872.3930

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Hudens Bio Co., Ltd. · LYC Bone Grafting Material, Synthetic

Cleared on Mar 6, 2026 as substantially equivalent to K112716 (Genoss Co., Ltd., 2012) after a 266-day review. Its family tree reaches back 7 generations to 1999.

Decided
Mar 6, 2026
Review
266 days
Class
Class II
Product code
LYC
Recalls
None
Predicates
1

Its longest line of descent runs back 7 generations to K990131 (1999). 8 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 7 generations backK990131 Pro Osteon Implant 500R Resorbable Bone Graft SubstituteInterpore Cross Intl. · 1999
  2. 6 generations backK020986 Mastergraft Resorbable CeramicMedtronic Sofamor Danek, Inc. · 2002
  3. 5 generations backK032268 MBCPBiomatlante · 2003
  4. 4 generations backK043005 Modification to MBCPBiomatlante · 2005
  5. 3 generations backK051885 MBCPBiomatlante · 2005
  6. 2 generations backK062834 Osteon, Models GBG0305, GBG0510, GBG1020, GBG2030, GBG3040, GBG4050Genoss Co., Ltd. · 2007
  7. 1 generation backK112716 Osteon IIGenoss Co., Ltd. · 2012
  8. This deviceK251818 Bontree PlusHudens Bio Co., Ltd. · 2026
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K990131Pro Osteon Implant 500R Resorbable Bone Graft SubstituteInterpore Cross Intl.1999—
−6K020986Mastergraft Resorbable CeramicMedtronic Sofamor Danek, Inc.2002—
−5K032268MBCPBiomatlante2003—
−4K043005Modification to MBCPBiomatlante2005—
−3K051885MBCPBiomatlante2005—
−2K062834Osteon, Models GBG0305, GBG0510, GBG1020, GBG2030, GBG3040, GBG4050Genoss Co., Ltd.2007—
−1K112716Osteon IIGenoss Co., Ltd.2012—
0 (this device)K251818Bontree PlusHudens Bio Co., Ltd.2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200010
FIG. 1 — Lineage of K251818, 1999–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LYC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LYC device

  1. #1 K253317 Cytrans™ Elashieldscore 14.3 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K112716Osteon II
Summary page 5
…: Class II 4. Predicate Device Information • Sponsor: GENOSS Co., Ltd. • Trade Name: OSTEON II • Classification Name: Bone grafting material, Synthetic • 510(k) Number: K112716 • Product Code: LYC • Regulation Number: 21 CFR 872.3930 • Regulation Class: Class II 510(k) Summary…
Genoss Co., Ltd.2012—
†K123633TRS Cranial Bone Void Filler (TRS C-BVF)Tissue Regeneration Systems, Inc.2013—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 27 years and passes through 5 companies; a new generation was cleared every 1.6 years on median.
  • None of the 8 ancestors has a recall.

How does its category compare?

All LYC devices

LYC Bone Grafting Material, Synthetic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.

FDA decisions per year · LYC

3in 2025

2007: 132008: 82009: 142010: 132011: 92012: 52013: 22014: 12016: 22020: 32022: 22025: 32026 (partial year): 3
2007high 14 (2009) · low 0 (2015)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LYC

267in 2025

2007: 80 days median2008: 73 days median2009: 100 days median2010: 164 days median2011: 224 days median2012: 120 days median2020: 156 days median2025: 267 days median2026 (partial year): 266 days median
2007high 267 (2025) · low 73 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LYC

1in 2018

2009: 12010: 22012: 22016: 22018: 1
2007high 2 (2010) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LYC

2in 2025

2007: 232008: 252009: 252010: 282011: 212012: 102013: 122014: 92015: 142016: 1402017: 192018: 142019: 152020: 52021: 122022: 62023: 92024: 62025: 2
2007high 140 (2016) · low 2 (2025)2025

MAUDE reports naming product code LYC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071380023
2008873025
200914100125
201013164228
20119224021
20125120210
20132—012
20141—09
20150—014
20162—2140
20170—019
20180—114
20190—015
2020315605
20210—012
20222—06
20230—09
20240—06
2025326702
202632660—

What is it indicated for?

BONTREE PLUS is intended for use as a bone grafting material to fill, augment or reconstruct periodontal or oral/maxillofacial defects, including

- Periodontal/infrabony defects

- Ridge augmentation

- Extraction sites (implant preparation/placement)

- Sinus lifts

- Cystic cavities

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K251818: Bontree Plus.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K251818

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026