510(k) Report

510(k) · Cleared

Cleared

JFord Speculum Sleeve™

K252208510(k) TraditionalCleared Mar 6, 2026234-day reviewClass II21 CFR 884.4530

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Ford Medtech, LLC · HIB Speculum, Vaginal, Nonmetal

Cleared on Mar 6, 2026 as substantially equivalent to K130046 (Clearspec, LLC, 2013) after a 234-day review. Its family tree reaches back 4 generations to 1994.

Decided
Mar 6, 2026
Review
234 days
Class
Class II
Product code
HIB
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to K941272 (1994). 5 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 4 generations backK941272 KleenspecWelch Allyn, Inc. · 1994
  2. 3 generations backK070964 Kleenspec Single Use Vaginal Speculum and 790 Series Cordless…Welch Allyn, Inc. · 2007
  3. 2 generations backK120743 Speculum, Vaginal, NonmetalWelch Allyn, Inc. · 2012 · Recalled
  4. 1 generation backK130046 Clearspec Single Use Vaginal SpeculumClearspec, LLC · 2013
  5. This deviceK252208 JFord Speculum Sleeve™Ford Medtech, LLC · 2026
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K941272KleenspecWelch Allyn, Inc.1994—
−3K070964Kleenspec Single Use Vaginal Speculum and 790 Series Cordless Illumination…Welch Allyn, Inc.2007—
−2K120743Speculum, Vaginal, NonmetalWelch Allyn, Inc.20121
−1K130046Clearspec Single Use Vaginal SpeculumClearspec, LLC2013—
0 (this device)K252208JFord Speculum Sleeve™Ford Medtech, LLC2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200510
FIG. 1 — Lineage of K252208, 1994–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HIB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K130046Clearspec Single Use Vaginal Speculum
Summary page 5
…Regulatory Class: 2 Product Code: HIB 3. Predicate Device Predicate Device: ClearSpec® Single Use Vaginal Speculum (K130046) The predicate has not been subject to a design-related recall. 4. Device Description The JFord Speculum Sleeve™…
Clearspec, LLC2013—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 32 years and passes through 3 companies; a new generation was cleared every 12.6 years on median.
  • 1 of the 5 ancestors has a recall of any class.

How does its category compare?

All HIB devices

HIB Speculum, Vaginal, Nonmetal: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.

FDA decisions per year · HIB

2in 2014

2007: 12008: 22009: 12010: 12011: 12012: 12013: 12014: 22026 (partial year): 1
2007high 2 (2008) · low 0 (2015)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HIB

Too few HIB 510(k)s in any year since 2007 to give a median.

Recalls per year · HIB

1in 2015

2015: 12026 (partial year): 1
2007high 1 (2015) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HIB

3in 2025

2007: 12008: 22009: 12010: 102011: 152012: 152013: 92014: 82015: 52016: 22017: 52018: 32019: 42020: 42021: 42022: 22023: 32024: 22025: 3
2007high 15 (2011) · low 1 (2007)2025

MAUDE reports naming product code HIB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—01
20082—02
20091—01
20101—010
20111—015
20121—015
20131—09
20142—08
20150—15
20160—02
20170—05
20180—03
20190—04
20200—04
20210—04
20220—02
20230—03
20240—02
20250—03
20261—1—

What is it indicated for?

The JFord Speculum Sleeve™ is a single use, inflatable vaginal wall retraction sleeve intended for use with a vaginal speculum to dilate the vagina and expose the interior of the vagina and exterior of the cervix during pelvic examinations and other gynecological procedures.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K252208: JFord Speculum Sleeve™.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K252208

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026