510(k) · Cleared
ClearedAtlas Spine HiRISE™ Expandable Cervical Corpectomy System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Atlas Spine, Inc. · PLR Spinal Vertebral Body Replacement Device - Cervical
Cleared on Nov 10, 2025 after an 89-day review. FDA’s file for it is a 510(k) statement, which names no predicate.
- Decided
- Nov 10, 2025
- Review
- 89 days
- Class
- Class II
- Product code
- PLR
- Recalls
- None
- Predicates
- 0
FDA’s file for it is a 510(k) statement, which names no predicate.
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in PLR? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new PLR device
- #1 K232481 RIGEL™ 3DR Anterior Cervical Corpectomy Systemscore 13.1 · 24 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All PLR devicesPLR Spinal Vertebral Body Replacement Device - Cervical: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.
FDA decisions per year · PLR
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · PLR
69in 2019
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · PLR
No recall names PLR since 2007.
Adverse event reports per year · PLR
1in 2025
MAUDE reports naming product code PLR, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 0 |
| 2011 | 0 | — | 0 | 0 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 0 | — | 0 | 0 |
| 2014 | 0 | — | 0 | 0 |
| 2015 | 1 | — | 0 | 0 |
| 2016 | 1 | — | 0 | 0 |
| 2017 | 1 | — | 0 | 0 |
| 2018 | 3 | 259 | 0 | 1 |
| 2019 | 5 | 69 | 0 | 1 |
| 2020 | 2 | — | 0 | 2 |
| 2021 | 0 | — | 0 | 4 |
| 2022 | 2 | — | 0 | 1 |
| 2023 | 2 | — | 0 | 0 |
| 2024 | 0 | — | 0 | 0 |
| 2025 | 1 | — | 0 | 1 |
| 2026 | 1 | — | 0 | — |
What is it indicated for?
The Atlas Spine HiRISE™ Expandable Cervical Corpectomy System is indicated for vertebral body replacement in the cervical spine (C2-T1). The System is designed for use with autogenous and/or allogeneic bone graft comprised of cancellous and/or corticocancellous bone graft as an adjunct to fusion. When used in the cervical spine (C2-T1), Atlas Spine HiRISE™ Expandable Cervical Corpectomy System spacers are intended for use in skeletally mature patients to…
Read the full statement (178 words)
The Atlas Spine HiRISE™ Expandable Cervical Corpectomy System is indicated for vertebral body replacement in the cervical spine (C2-T1). The System is designed for use with autogenous and/or allogeneic bone graft comprised of cancellous and/or corticocancellous bone graft as an adjunct to fusion.
When used in the cervical spine (C2-T1), Atlas Spine HiRISE™ Expandable Cervical Corpectomy System spacers are intended for use in skeletally mature patients to replace a diseased or damaged vertebral body caused by tumor, fracture, or osteomyelitis, or for reconstruction following corpectomy performed to achieve decompression of the spinal cord and neural tissues in the cervical degenerative disorders. These spacers are intended to restore the integrity of the spinal column even in the absence of fusion for a limited time period in patients with advanced stage tumors involving the cervical spine in whom life expectancy is of insufficient duration to permit achievement of fusion, with bone graft used at the surgeon's discretion. The System is intended to be used with supplemental fixation that has been cleared by the FDA for use in the cervical spine.
Indications for use as stated in the FDA 510(k) statement.
https://510kreport.com/device/K252560 · printed Nov 6, 2026
Cite this page
510(k) Report. “K252560: Atlas Spine HiRISE™ Expandable Cervical Corpectomy System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K252560
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026