510(k) · Cleared
ClearedPediatric Plating Platform I Small-Mini
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
OrthoPediatrics Corp. · HRS Plate, Fixation, Bone
Cleared on Oct 9, 2025 as substantially equivalent to K140814 (Smith & Nephew, Inc., 2014) and 3 other predicates after a 52-day review. Its family tree reaches back 13 generations to 1996.
- Decided
- Oct 9, 2025
- Review
- 52 days
- Class
- Class II
- Product code
- HRS
- Recalls
- None
- Predicates
- 4
Its longest line of descent runs back 13 generations to K962616 (1996). 143 ancestors in all, the oldest K792022 (1979). No later device cites it as a predicate yet.
- Root · 13 generations backK962616 Synthes Dorsal Distal Radius Plate (DDRP) SystemSynthes (Usa) · 1996
- 9 generations between
- 3 generations backK170887 EVOS Small Fragment Plating SystemSmith & Nephew, Inc. · 2017
- 2 generations backK173293 EVOS Small Fragment Upper Extremity PlatesSmith & Nephew, Inc. · 2018
- 1 generation backK190253 EVOS Small Fragment Upper Extremity Plates Line AdditionsSmith & Nephew, Inc. · 2019
- This deviceK252600 Pediatric Plating Platform I Small-MiniOrthoPediatrics Corp. · 2025
Show all 13 generations
- Root · 13 generations backK962616 Synthes Dorsal Distal Radius Plate (DDRP) SystemSynthes (Usa) · 1996
- 12 generations backK982732 Synthes (Usa) Distal Radius Plate System (DRPS)Synthes · 1998
- 11 generations backK023007 Distal Radius Fracture Repair SystemHand Innovations, Inc. · 2002
- 10 generations backK030198 Hand Innovations, Inc. Distal Radius Fracture Repair SystemHand Innovations, Inc. · 2003
- 9 generations backK032705 Distal Radius Fracture Repair SystemHand Innovations, Inc. · 2003
- 8 generations backK050932 Distal Volar Radius Anatomical Plate SystemHand Innovations, Inc. · 2005 · Recalled
- 7 generations backK051735 Peri-Loc Locking Bone Plates and Locking Bone Screws for the Upper…Smith & Nephew, Inc. · 2005
- 6 generations backK061352 Peri-Loc Periarticular Locked Plating System for the Upper ExtremitySmith & Nephew, Inc. · 2006
- 5 generations backK082516 Peri-Loc Periarticular Locked Plating System Hexalobular Bone ScrewsSmith & Nephew, Inc. · 2008
- 4 generations backK100325 Peri-Loc Locking Hole Inserts and Cable AccessoriesSmith & Nephew, Inc. · 2010
- 3 generations backK170887 EVOS Small Fragment Plating SystemSmith & Nephew, Inc. · 2017
- 2 generations backK173293 EVOS Small Fragment Upper Extremity PlatesSmith & Nephew, Inc. · 2018
- 1 generation backK190253 EVOS Small Fragment Upper Extremity Plates Line AdditionsSmith & Nephew, Inc. · 2019
- This deviceK252600 Pediatric Plating Platform I Small-MiniOrthoPediatrics Corp. · 2025
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −13 | K962616 | Synthes Dorsal Distal Radius Plate (DDRP) System | Synthes (Usa) | 1996 | — |
| −12 | K982732 | Synthes (Usa) Distal Radius Plate System (DRPS) | Synthes | 1998 | — |
| −11 | K023007 | Distal Radius Fracture Repair System | Hand Innovations, Inc. | 2002 | — |
| −10 | K030198 | Hand Innovations, Inc. Distal Radius Fracture Repair System | Hand Innovations, Inc. | 2003 | — |
| −9 | K032705 | Distal Radius Fracture Repair System | Hand Innovations, Inc. | 2003 | — |
| −8 | K050932 | Distal Volar Radius Anatomical Plate System | Hand Innovations, Inc. | 2005 | 1 |
| −7 | K051735 | Peri-Loc Locking Bone Plates and Locking Bone Screws for the Upper Extremity | Smith & Nephew, Inc. | 2005 | — |
| −6 | K061352 | Peri-Loc Periarticular Locked Plating System for the Upper Extremity | Smith & Nephew, Inc. | 2006 | — |
| −5 | K082516 | Peri-Loc Periarticular Locked Plating System Hexalobular Bone Screws | Smith & Nephew, Inc. | 2008 | — |
| −4 | K100325 | Peri-Loc Locking Hole Inserts and Cable Accessories | Smith & Nephew, Inc. | 2010 | — |
| −3 | K170887 | EVOS Small Fragment Plating System | Smith & Nephew, Inc. | 2017 | — |
| −2 | K173293 | EVOS Small Fragment Upper Extremity Plates | Smith & Nephew, Inc. | 2018 | — |
| −1 | K190253 | EVOS Small Fragment Upper Extremity Plates Line Additions | Smith & Nephew, Inc. | 2019 | — |
| 0 (this device) | K252600 | Pediatric Plating Platform I Small-Mini | OrthoPediatrics Corp. | 2025 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1979 | 1 | 0 |
| 1982 | 1 | 0 |
| 1986 | 1 | 0 |
| 1989 | 2 | 0 |
| 1990 | 2 | 0 |
| 1991 | 1 | 0 |
| 1993 | 2 | 0 |
| 1994 | 1 | 0 |
| 1995 | 7 | 0 |
| 1996 | 10 | 0 |
| 1997 | 5 | 0 |
| 1998 | 6 | 0 |
| 1999 | 5 | 0 |
| 2000 | 12 | 0 |
| 2001 | 13 | 0 |
| 2002 | 5 | 0 |
| 2003 | 4 | 0 |
| 2004 | 10 | 0 |
| 2005 | 8 | 0 |
| 2006 | 6 | 0 |
| 2007 | 6 | 0 |
| 2008 | 6 | 0 |
| 2009 | 7 | 0 |
| 2010 | 2 | 0 |
| 2011 | 1 | 0 |
| 2013 | 1 | 0 |
| 2014 | 3 | 0 |
| 2016 | 1 | 0 |
| 2017 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in HRS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new HRS device
- #1 K222465 Tyber Medical Anatomical Plating Systemscore 27.5 · 16 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (4)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K140814 | Evos Mini-Fragment Plating SystemSummary page 5…Fixation, Bone III. Predicate Device and Reference Device Primary predicate device: EVOS Mini-Fragment Plating System - Smith & Nephew, Inc. K140814 Additional predicate devices: EVOS Small Fragment Plating System - Smith & Nephew, Inc. K170887 EVOS Small… | 2014 |
| * | K170887 | EVOS Small Fragment Plating SystemSummary page 5…S Mini-Fragment Plating System - Smith & Nephew, Inc. K140814 Additional predicate devices: EVOS Small Fragment Plating System - Smith & Nephew, Inc. K170887 EVOS Small Fragment Upper Extremity Plates - Smith & Nephew, Inc. K190253 PediLoc Fragment System… | 2017 |
| * | K190253 | EVOS Small Fragment Upper Extremity Plates Line AdditionsSummary page 5…evices: EVOS Small Fragment Plating System - Smith & Nephew, Inc. K170887 EVOS Small Fragment Upper Extremity Plates - Smith & Nephew, Inc. K190253 PediLoc Fragment System - OrthoPediatrics Corp. K140431… | 2019 |
| * | K140431 | Pediloc Fragment SystemSummary page 5…K170887 EVOS Small Fragment Upper Extremity Plates - Smith & Nephew, Inc. K190253 PediLoc Fragment System - OrthoPediatrics Corp. K140431 Page 1 of 3 OrthoPediatrics… | 2014 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 29 years and passes through 5 companies; a new generation was cleared every 1.6 years on median.
- 37 of the 143 ancestors have a recall of any class.
- 10 other devices also cite its predicate K140814.
How does its category compare?
All HRS devicesHRS Plate, Fixation, Bone: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.
FDA decisions per year · HRS
54in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · HRS
90in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · HRS
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · HRS
2,306in 2025
MAUDE reports naming product code HRS, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 35 | 63 | 2 | 339 |
| 2008 | 35 | 87 | 11 | 311 |
| 2009 | 47 | 85 | 3 | 435 |
| 2010 | 49 | 100 | 16 | 491 |
| 2011 | 43 | 88 | 5 | 773 |
| 2012 | 59 | 106 | 4 | 1,663 |
| 2013 | 56 | 89 | 11 | 2,643 |
| 2014 | 76 | 57 | 0 | 2,413 |
| 2015 | 56 | 97 | 7 | 3,095 |
| 2016 | 44 | 109 | 5 | 2,276 |
| 2017 | 57 | 122 | 3 | 2,220 |
| 2018 | 40 | 116 | 2 | 2,663 |
| 2019 | 46 | 89 | 25 | 3,359 |
| 2020 | 48 | 88 | 1 | 2,790 |
| 2021 | 40 | 87 | 9 | 2,442 |
| 2022 | 47 | 144 | 3 | 1,700 |
| 2023 | 40 | 120 | 1 | 2,049 |
| 2024 | 54 | 96 | 0 | 1,849 |
| 2025 | 54 | 90 | 1 | 2,306 |
| 2026 | 51 | 82 | 3 | — |
What is it indicated for?
The Pediatric Plating Platform I Small-Mini is indicated for internal fracture fixation, osteotomies, mal-unions, and non-unions of bones and bone fragments of the appendicular skeleton appropriate for the implant size. The Pediatric Plating Platform I Small-mini is intended for children (2-12 years) and adolescents (12-21 years) in which growth plates have fused or in which unfused growth plates will not be compromised by fixation, and adults. If used in the femur, tibia, humerus, patella, or pelvis the Pediatric Plating Platform I Small-Mini can only be used for non-load bearing stabilization and reduction.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K252600 · printed Nov 5, 2026
Cite this page
510(k) Report. “K252600: Pediatric Plating Platform I Small-Mini.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K252600
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026