510(k) · Cleared
ClearedCaseBio™ Culture w/HSA (CMH5); CaseBio™ Handling w/HSA (WHH5)
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Casebioscience, Inc. · MQL Media, Reproductive
Cleared on Feb 20, 2026 as substantially equivalent to K242107 (Casebioscience, Inc., 2025) after a 179-day review. Its family tree reaches back 2 generations to 2024.
- Decided
- Feb 20, 2026
- Review
- 179 days
- Class
- Class II
- Product code
- MQL
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 2 generations to K240149 (2024). No later device cites it as a predicate yet.
- Root · 2 generations backK240149 Giftlife™ Fertilization Medium; Giftlife™ Cleavage Medium; Giftlife™…Gimbo Medical Technology Shenzhen Co., Ltd. · 2024
- 1 generation backK242107 CaseMONO™ Culture (CMON); CaseMONO™ w/HEPES (WHMO); CaseBioscience®…Casebioscience, Inc. · 2025
- This deviceK252672 CaseBio™ Culture w/HSA (CMH5); CaseBio™ Handling w/HSA (WHH5)Casebioscience, Inc. · 2026
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K240149 | Giftlife™ Fertilization Medium; Giftlife™ Cleavage Medium; Giftlife™… | Gimbo Medical Technology Shenzhen Co., Ltd. | 2024 | — |
| −1 | K242107 | CaseMONO™ Culture (CMON); CaseMONO™ w/HEPES (WHMO); CaseBioscience® HTF… | Casebioscience, Inc. | 2025 | — |
| 0 (this device) | K252672 | CaseBio™ Culture w/HSA (CMH5); CaseBio™ Handling w/HSA (WHH5) | Casebioscience, Inc. | 2026 | — |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MQL? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new MQL device
- #1 K251305 Ultra-Fast Vitri; Ultra-Fast Warmscore 14.4 · 6 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K242107 | CaseMONO™ Culture (CMON); CaseMONO™ w/HEPES (WHMO); CaseBioscience® HTF (HTFC)…Summary page 5…mber: 884.6180 Product Code: MQL (Media, Reproductive) Regulatory Class: II III. PREDICATE DEVICE CaseMONO™ Culture (CMON); CaseMONO™ w/HEPES (WHMO); (K242107) from CaseBioscience, Inc. The predicate device has not been subject to a design-related recall. IV. DEVICE DESCRIPTION… | 2025 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 2 years and passes through 2 companies; a new generation was cleared every 11 months on median.
- None of the 2 ancestors has a recall.
How does its category compare?
All MQL devicesMQL Media, Reproductive: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.
FDA decisions per year · MQL
9in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · MQL
225in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MQL
1in 2023
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MQL
3in 2025
MAUDE reports naming product code MQL, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 3 | 212 | 0 | 0 |
| 2008 | 12 | 151 | 0 | 0 |
| 2009 | 2 | — | 0 | 0 |
| 2010 | 6 | 235 | 0 | 0 |
| 2011 | 1 | — | 0 | 0 |
| 2012 | 5 | 253 | 1 | 1 |
| 2013 | 0 | — | 0 | 2 |
| 2014 | 5 | 142 | 0 | 3 |
| 2015 | 7 | 87 | 0 | 0 |
| 2016 | 12 | 170 | 0 | 2 |
| 2017 | 10 | 113 | 0 | 0 |
| 2018 | 4 | 94 | 0 | 0 |
| 2019 | 6 | 170 | 0 | 0 |
| 2020 | 8 | 257 | 1 | 0 |
| 2021 | 1 | — | 2 | 0 |
| 2022 | 3 | 316 | 1 | 0 |
| 2023 | 5 | 199 | 1 | 1 |
| 2024 | 12 | 195 | 0 | 6 |
| 2025 | 9 | 225 | 0 | 3 |
| 2026 | 3 | 179 | 0 | — |
What is it indicated for?
CaseBio™ Culture w/HSA is intended for use for culture of embryos from fertilization to the blastocyst stage. This device can be used for transfer of embryos to the uterus.
CaseBio™ Handling w/HSA is intended for use in short-term handling and manipulating gametes and embryos, including washing and intracytoplasmic sperm injection (ICSI). This medium is not intended for transferring embryos to the uterine cavity.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K252672 · printed Nov 4, 2026
Cite this page
510(k) Report. “K252672: CaseBio™ Culture w/HSA (CMH5); CaseBio™ Handling w/HSA (WHH5).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K252672
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026