510(k) Report

510(k) · Decided

Recalled · Class II · 2026

Orca Air/Water and Suction Valves

K252910510(k) SpecialDecided Oct 9, 202527-day reviewClass II21 CFR 876.1500Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Boston Scientific · ODC Endoscope Channel Accessory

Cleared on Oct 9, 2025 as substantially equivalent to K160403 (Endochoice, Inc., 2016) after a 27-day review. Its family tree reaches back 3 generations to 2000. It has been recalled once.

Decided
Oct 9, 2025
Review
27 days
Class
Class II
Product code
ODC
Recalls
1
Predicates
1

Its longest line of descent runs back 3 generations to K001241 (2000). 4 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 3 generations backK001241 Evis Exera Colonovideoscope CF-Q160 AL/I and PCF-160 AL/IThe Olympus Optical Co. · 2000 · Recalled
  2. 2 generations backK102409 Defendo Disposable Air/Water Valve Model 100304Byrne Medical, Inc. · 2010
  3. 1 generation backK160403 SmartStart Air/Water and Suction ValvesEndochoice, Inc. · 2016
  4. This deviceK252910 Orca Air/Water and Suction ValvesBoston Scientific · 2025
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K001241Evis Exera Colonovideoscope CF-Q160 AL/I and PCF-160 AL/IThe Olympus Optical Co.20001
−2K102409Defendo Disposable Air/Water Valve Model 100304Byrne Medical, Inc.2010—
−1K160403SmartStart Air/Water and Suction ValvesEndochoice, Inc.2016—
0 (this device)K252910Orca Air/Water and Suction ValvesBoston Scientific2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
201010
FIG. 1 — Lineage of K252910, 2000–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in ODC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new ODC device

  1. #1 K232329 Defendo Fujifilm 700 Single Use Biopsy Valve…score 14.0 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K160403SmartStart Air/Water and Suction Valves
Summary page 5
…1500 Product Code: ODC Classification: Class II III. Predicate Device Orca Air/Water and Suction Valves, K160403 This predicate has not been subject to a design-related recall. No reference devices were use…
Endochoice, Inc.2016—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
May 12, 2026Class IIZ-2413-2026Process controlBoston Scientific is initiating a medical device removal of Orca Sterile, Single Use Air/Water and Suction Valves due to a higher than anticipated occurrence of the suction button sticking.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 25 years and passes through 4 companies; a new generation was cleared every 9.4 years on median.
  • 1 of the 4 ancestors has a recall of any class.

How does its category compare?

All ODC devices

ODC Endoscope Channel Accessory: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.

FDA decisions per year · ODC

6in 2025

2008: 32009: 12010: 42011: 42012: 22015: 22016: 12017: 12018: 22019: 42020: 42021: 62022: 82023: 72024: 82025: 62026 (partial year): 1
2007high 8 (2022) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · ODC

106in 2025

2008: 83 days median2010: 67 days median2011: 143 days median2019: 55 days median2020: 128 days median2021: 181 days median2022: 118 days median2023: 126 days median2024: 95 days median2025: 106 days median
2007high 181 (2021) · low 55 (2019)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · ODC

1so far in 2026, the most since 2007

2026 (partial year): 1
2007high 1 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · ODC

91in 2025

2012: 12013: 12014: 22015: 32016: 82017: 122018: 172019: 402020: 542021: 522022: 372023: 432024: 1002025: 91
2007high 100 (2024) · low 0 (2007)2025

MAUDE reports naming product code ODC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
200838300
20091—00
201046700
2011414300
20122—01
20130—01
20140—02
20152—03
20161—08
20171—012
20182—017
2019455040
20204128054
20216181052
20228118037
20237126043
20248950100
20256106091
20261—1—

What is it indicated for?

The Orca Air/Water Valve is intended to be used to control the air/water function on an endoscope during a GI (gastrointestinal) endoscopic procedure.

The Orca Suction Valve is intended to be used to control the suction function on an endoscope during a GI endoscopic procedure.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K252910: Orca Air/Water and Suction Valves.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K252910

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026