510(k) · Cleared
ClearedVR® Personal Protective Level 3 Gown (VR Gowns)
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
PolyConversions, Inc. · QPC Gown, Non-Sterile, Non-Isolation, Intended To Provide Moderate Or High Barrier Protection
Cleared on Dec 16, 2025 after a 92-day review. FDA’s file for it is a 510(k) statement, which names no predicate.
- Decided
- Dec 16, 2025
- Review
- 92 days
- Class
- Class II
- Product code
- QPC
- Recalls
- None
- Predicates
- 0
FDA’s file for it is a 510(k) statement, which names no predicate.
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in QPC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new QPC device
- #1 K262007 PRIMED AAMI Level 3 Open Back Gownsscore 12.9 · 4 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All QPC devicesQPC Gown, Non-Sterile, Non-Isolation, Intended To Provide Moderate Or High Barrier Protection: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.
FDA decisions per year · QPC
2in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · QPC
Too few QPC 510(k)s in any year since 2007 to give a median.
Recalls per year · QPC
No recall names QPC since 2007.
Adverse event reports per year · QPC
No MAUDE report names QPC since 2007.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 0 |
| 2011 | 0 | — | 0 | 0 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 0 | — | 0 | 0 |
| 2014 | 0 | — | 0 | 0 |
| 2015 | 0 | — | 0 | 0 |
| 2016 | 0 | — | 0 | 0 |
| 2017 | 1 | — | 0 | 0 |
| 2018 | 0 | — | 0 | 0 |
| 2019 | 1 | — | 0 | 0 |
| 2020 | 0 | — | 0 | 0 |
| 2021 | 2 | — | 0 | 0 |
| 2022 | 1 | — | 0 | 0 |
| 2023 | 2 | — | 0 | 0 |
| 2024 | 1 | — | 0 | 0 |
| 2025 | 2 | — | 0 | 0 |
| 2026 | 2 | — | 0 | — |
What is it indicated for?
The VR® Personal Protective Level 3 Gown is intended to protect healthcare patients and health care personnel from the transfer of microorganisms, body fluids and particulate material. The VR® Personal Protective Level 3 Gown is a single use, disposable gown provided non-sterile. The back of the VR Gown is open and non-protective. The VR Gown is not intended for use in the operating room.
Indications for use as stated in the FDA 510(k) statement.
https://510kreport.com/device/K252940 · printed Nov 4, 2026
Cite this page
510(k) Report. “K252940: VR® Personal Protective Level 3 Gown (VR Gowns).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K252940
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026