Esthetic Medical, Inc. · QAI Powered Microneedle Device
Cleared on Feb 19, 2026 as substantially equivalent to K180778 (Mt. Derm GmbH, 2018) after a 153-day review. Its family tree reaches back 2 generations to 2018.
- Decided
- Feb 19, 2026
- Review
- 153 days
- Class
- Class II
- Product code
- QAI
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 2 generations to DEN160029 (2018). No later device cites it as a predicate yet.
View FIG. 1 as a table
Line of descent and top descendants
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in QAI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new QAI device
- #1 K230420 Dr. pen Microneedling Systemscore 14.8 · 1 generation · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K180778 | Exceed Microneedling DeviceSummary page 5…r: 21 CFR 878.4430 Product Code: QAI Review Panel: General & Plastic Surgery Predicate Device: K180778. Exceed Microneedling Device Intended Use 1 The SkinStylus SteriLock® MicroSystem is intended to be used as a treatment to impr… | 2018 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 8 years and passes through 3 companies; a new generation was cleared every 7.5 years on median.
- None of the 2 ancestors has a recall.
- 3 other devices also cite its predicate K180778.
How does its category compare?
All QAI devicesQAI Powered Microneedle Device: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.
FDA decisions per year · QAI
6in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · QAI
160in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · QAI
1in 2019
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · QAI
11in 2025
MAUDE reports naming product code QAI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 0 |
| 2011 | 0 | — | 0 | 0 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 0 | — | 0 | 0 |
| 2014 | 0 | — | 0 | 0 |
| 2015 | 0 | — | 0 | 0 |
| 2016 | 0 | — | 0 | 0 |
| 2017 | 0 | — | 0 | 0 |
| 2018 | 2 | — | 0 | 0 |
| 2019 | 1 | — | 1 | 0 |
| 2020 | 2 | — | 0 | 1 |
| 2021 | 4 | 226 | 0 | 2 |
| 2022 | 4 | 172 | 0 | 6 |
| 2023 | 2 | — | 0 | 29 |
| 2024 | 3 | 104 | 0 | 5 |
| 2025 | 6 | 160 | 0 | 11 |
| 2026 | 2 | — | 0 | — |
What is it indicated for?
The SkinStylus SteriLock® MicroSystem is a microneedling device and accessories intended to be used as a treatment to improve the appearance of periorbital wrinkles in Fitzpatrick skin types I, II, III, IV, V, and VI in adults aged 34 years or older.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K253002 · printed Nov 4, 2026
Cite this page
510(k) Report. “K253002: SkinStylus SteriLock MicroSystem (MP1209SL).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K253002
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026