# K253173: uCT 780 with uWS-CT-Dual Energy Analysis

- Pathway: 510(k) (Traditional)
- Applicant: Shanghai United Imaging Healthcare Co., Ltd.
- Decided: Jan 20, 2026 after 116 days
- Product code: JAK (System, X-Ray, Tomography, Computed)
- Device class: 2
- Regulation: 21 CFR 892.1750
- Recalls of this device: 1 (0 Class I)
- Data: FDA decisions to Oct 25, 2026; recalls to Oct 12, 2026

## Lineage
Longest line of descent: 17 generations back to K013561 (2001). 60 ancestors in all.
No later device cites it as a predicate yet.
0 of 61 devices in its family (counting itself) have a Class I recall.

## Predicates on the family tree (from the FDA summary)
- K241079: uCT 780, Shanghai United Imaging Healthcare Co., Ltd. (2025) Summary page 5.

## Recalls of this device
- Aug 11, 2026 · Class II · Z-3280-2026: Positron emission tomography and computed tomography x-ray systems have a software problem when Split or Local function is enabled, and multiple RIS exams are merged into a single study, that prevents

## Indications for use
uCT 780 is a computed tomography x-ray system intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data taken at different angles and planes and indicated for the whole body (including head, neck, cardiac and vascular). uCT 780 is intended to be used for low dose CT lung cancer screening for the early detection of lung nodules that may represent cancer. The screening must be performed within the established inclusion criteria of programs / protocols that have been approved and published by either a governmental body or professional medical society. * Please refer to clinical literature, including the results of the National Lung Screening Trial (N Engl J Med 2011; 365:395-409) and subsequent literature, for further information. uWS-CT-Dual Energy Analysis is a post-processing software package that accepts UIH CT images acquired using different tube voltages and/or tube currents of the same anatomical location. The various materials of an anatomical region of interest have different attenuation coefficients, which depend on the used energy. These differences provide information on the chemical composition of the scanned body materials and enable images to be generated at multiple energies within the available spectrum. uWS-CT-Dual Energy Analysis software combines images acquired with low and high energy spectra to visualize this information.