510(k) Report

510(k) · Cleared

Cleared

LCD Monitor (C1216W, C822W, C821W)

K253242510(k) SpecialCleared Oct 29, 202530-day reviewClass II21 CFR 892.2050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Shenzhen Beacon Display Technology Co., Ltd. · PGY Display, Diagnostic Radiology

Cleared on Oct 29, 2025 as substantially equivalent to K231026 (Shenzhen Beacon Display Technology Co., Ltd., 2023) and 2 other predicates after a 30-day review. Its family tree reaches back 7 generations to 2000.

Decided
Oct 29, 2025
Review
30 days
Class
Class II
Product code
PGY
Recalls
None
Predicates
3

Its longest line of descent runs back 7 generations to K000293 (2000). 20 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 7 generations backK000293 Barco MGD 221 2 Megapixel Diagnostic DisplayBarco N.V. · 2000
  2. 6 generations backK012099 Monochrome Perfectly Flat Panel Displays, ME SeriesTotoku Electric Co., Ltd. · 2001
  3. 5 generations backK022109 Eizo, Model FC-2091Eizo Nanao Corporation · 2002
  4. 4 generations backK041597 Monochrome LCD Monitor, Model Radiforce G22Eizo Nanao Corporation · 2004
  5. 3 generations backK070131 Radiforce GX220 and GS220 Monochrome LCD MonitorsEizo Nanao Corporation · 2007
  6. 2 generations backK120407 2MP Monochrome LCD Monitor, Radiforce GX240Eizo Nanao Corporation · 2012
  7. 1 generation backK172815 2MP LCD Monitor (G22S+, G22SP+, C22S+, C22SP+)Shenzhen Beacon Display Technology Co., Ltd. · 2017
  8. This deviceK253242 LCD Monitor (C1216W, C822W, C821W)Shenzhen Beacon Display Technology Co., Ltd. · 2025
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K000293Barco MGD 221 2 Megapixel Diagnostic DisplayBarco N.V.2000—
−6K012099Monochrome Perfectly Flat Panel Displays, ME SeriesTotoku Electric Co., Ltd.2001—
−5K022109Eizo, Model FC-2091Eizo Nanao Corporation2002—
−4K041597Monochrome LCD Monitor, Model Radiforce G22Eizo Nanao Corporation2004—
−3K070131Radiforce GX220 and GS220 Monochrome LCD MonitorsEizo Nanao Corporation2007—
−2K1204072MP Monochrome LCD Monitor, Radiforce GX240Eizo Nanao Corporation2012—
−1K1728152MP LCD Monitor (G22S+, G22SP+, C22S+, C22SP+)Shenzhen Beacon Display Technology Co., Ltd.2017—
0 (this device)K253242LCD Monitor (C1216W, C822W, C821W)Shenzhen Beacon Display Technology Co., Ltd.2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
201010
201110
201210
201520
201630
201710
201910
202020
202310
FIG. 1 — Lineage of K253242, 2000–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in PGY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new PGY device

  1. #1 K261213 Medical Monitor (40HT513D)score 13.9 · 9 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K23102612MP Color LCD Monitor C1216W, C12*** (* = 0 to 9, A to Z or blank, and the difference…
Summary page 5
…entification of Predicate Device(s) The identified predicate devices within this submission are as follows. Predicate Device for C1216W  510(k) Number: K231026  Applicant: Shenzhen Beacon Display Technology Co., Ltd.  Trade Name: C1216W Predicate Device for C822W…
Shenzhen Beacon Display Technology Co., Ltd.2023—
*K1728152MP LCD Monitor (G22S+, G22SP+, C22S+, C22SP+)
Summary page 5
…k) Number: K231026  Applicant: Shenzhen Beacon Display Technology Co., Ltd.  Trade Name: C1216W Predicate Device for C822W  510(k) Number: K172815 510(k) Summary 1 LCD Monitors…
Shenzhen Beacon Display Technology Co., Ltd.2017—
*K2008645MP Color LCD Monitors C53S+, C53SP+, 5MP Monochrome LCD Monitors G53S+, G53SP+
Summary page 6
…510(k) Submission  Applicant: Shenzhen Beacon Display Technology Co., Ltd.  Trade Name: C22S+ Predicate Device for C821W  510(k) Number: K200864  Applicant: Shenzhen Beacon Display Technology Co., Ltd.  Trade Name: C53S+ 4. Description of the Device C12…
Shenzhen Beacon Display Technology Co., Ltd.2020—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 25 years and passes through 4 companies; a new generation was cleared every 2.6 years on median.
  • None of the 20 ancestors has a recall.

How does its category compare?

All PGY devices

PGY Display, Diagnostic Radiology: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.

FDA decisions per year · PGY

3in 2025

2014: 142015: 162016: 182017: 112018: 52019: 112020: 122021: 72022: 102023: 172024: 102025: 32026 (partial year): 4
2007high 18 (2016) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · PGY

59in 2025

2014: 24 days median2015: 31 days median2016: 27 days median2017: 30 days median2018: 28 days median2019: 58 days median2020: 61 days median2021: 77 days median2022: 60 days median2023: 60 days median2024: 53 days median2025: 59 days median2026 (partial year): 48 days median
2007high 77 (2021) · low 24 (2014)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · PGY

No recall names PGY since 2007.

Adverse event reports per year · PGY

1in 2017

2017: 1
2007high 1 (2017) · low 0 (2007)2025

MAUDE reports naming product code PGY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
2014142400
2015163100
2016182700
2017113001
201852800
2019115800
2020126100
202177700
2022106000
2023176000
2024105300
202535900
20264480—

What is it indicated for?

-- C822W This Medical Monitor is intended to be used in displaying and viewing digital images for review, analysis and diagnosis by trained medical practitioners. It does not support the display of mammography images for diagnosis. -- C1216W This Medical Monitor is indicated for use in displaying radiological images (including full-field digital mammography and digital breast tomosynthesis) for review, analysis, and diagnosis by trained medical…

Read the full statement (107 words)

-- C822W

This Medical Monitor is intended to be used in displaying and viewing digital images for review, analysis and diagnosis by trained medical practitioners. It does not support the display of mammography images for diagnosis.

-- C1216W

This Medical Monitor is indicated for use in displaying radiological images (including full-field digital mammography and digital breast tomosynthesis) for review, analysis, and diagnosis by trained medical practitioners.

-- C821W

This Medical Monitor is intended to be used in displaying and viewing medical images for diagnosis by trained medical practitioners or certified personnel. It's intended to be used in digital mammography PACS, digital breast tomosynthesis and modalities including FFDM.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K253242: LCD Monitor (C1216W, C822W, C821W).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K253242

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026