510(k) Report

510(k) · Cleared

Cleared

VitaloJAK Clinic (Model 7100)

K253293510(k) SpecialCleared Dec 3, 202565-day reviewClass II21 CFR 870.2800

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Vitalograph, Ltd. · DSH Recorder, Magnetic Tape, Medical

Cleared on Dec 3, 2025 as substantially equivalent to K110525 (Vitalograph (Ireland), Ltd., 2011) after a 65-day review. Its family tree reaches back 6 generations to 1995.

Decided
Dec 3, 2025
Review
65 days
Class
Class II
Product code
DSH
Recalls
None
Predicates
1

Its longest line of descent runs back 6 generations to K943862 (1995). 12 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 6 generations backK943862 Sonicaid Model MR-63 Ambulatory Ecg RecorderOxford Instruments Medical Systems · 1995
  2. 5 generations backK970902 Medilog FD4Oxford Instruments Medical Systems · 1997
  3. 4 generations backK070818 MEDILOGAR4, MEDILOGAR12Tom Medical Entwicklungs GmbH · 2007
  4. 3 generations backK083820 Vasomedical Biox CB-1305-C, 3 Channel Ecg Holter Monitor, Model…Vasomedical, Inc. · 2009
  5. 2 generations backK101022 Pulmotrack 5050 Wholter, Model 5050Karmelsonix · 2010
  6. 1 generation backK110525 Vitalograph Model 7100 - VitalojakVitalograph (Ireland), Ltd. · 2011
  7. This deviceK253293 VitaloJAK Clinic (Model 7100)Vitalograph, Ltd. · 2025
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K943862Sonicaid Model MR-63 Ambulatory Ecg RecorderOxford Instruments Medical Systems1995—
−5K970902Medilog FD4Oxford Instruments Medical Systems1997—
−4K070818MEDILOGAR4, MEDILOGAR12Tom Medical Entwicklungs GmbH2007—
−3K083820Vasomedical Biox CB-1305-C, 3 Channel Ecg Holter Monitor, Model CB-1305-CVasomedical, Inc.2009—
−2K101022Pulmotrack 5050 Wholter, Model 5050Karmelsonix2010—
−1K110525Vitalograph Model 7100 - VitalojakVitalograph (Ireland), Ltd.2011—
0 (this device)K253293VitaloJAK Clinic (Model 7100)Vitalograph, Ltd.2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199610
199810
199910
200010
200510
200710
FIG. 1 — Lineage of K253293, 1995–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DSH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DSH device

  1. #1 K260157 LifeLens Physiological Monitorscore 17.9 · 22 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K110525Vitalograph Model 7100 - Vitalojak
Summary page 6
…Vitalograph VitaloJAK Clinic Model Vitalograph VitaloJAK Model 7100 7100 (Cough Monitor) (K110525) Model and Device Name Vitalograph VitaloJAK Clinic Model Vitalograph VitaloJAK Model 7100 Yes, same n…
Vitalograph (Ireland), Ltd.2011—

Also cleared against K110525: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 30 years and passes through 6 companies; a new generation was cleared every 2.0 years on median.
  • None of the 12 ancestors has a recall.
  • 1 other device also cites its predicate K110525.

How does its category compare?

All DSH devices

DSH Recorder, Magnetic Tape, Medical: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.

FDA decisions per year · DSH

4in 2025

2007: 12008: 12009: 32010: 22011: 62012: 22013: 22014: 12015: 22016: 22017: 32018: 32019: 32020: 42021: 42022: 42023: 62024: 22025: 42026 (partial year): 2
2007high 6 (2011) · low 1 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DSH

205in 2025

2009: 84 days median2011: 64 days median2017: 91 days median2018: 269 days median2019: 30 days median2020: 122 days median2021: 263 days median2022: 427 days median2023: 198 days median2025: 205 days median
2007high 427 (2022) · low 30 (2019)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DSH

No recall names DSH since 2007.

Adverse event reports per year · DSH

213in 2025

2009: 12010: 82011: 32012: 12013: 22014: 32015: 82016: 62017: 312018: 302019: 762020: 912021: 1132022: 462023: 652024: 882025: 213
2007high 213 (2025) · low 0 (2007)2025

MAUDE reports naming product code DSH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20081—00
200938401
20102—08
201166403
20122—01
20132—02
20141—03
20152—08
20162—06
2017391031
20183269030
2019330076
20204122091
202142630113
20224427046
20236198065
20242—088
202542050213
20262—0—

What is it indicated for?

Vitalograph VitaloJAK Clinic Model 7100 is indicated for use to aid in the assessment of cough in adults and pediatric patients aged 8 years and older under supervision presenting with suspected Chronic Cough.

The Vitalograph VitaloJAK Clinic Model 7100 is a non-invasive battery-operated device intended to acquire, record and store ambulatory cough sounds from patients. The device stores the data on internal memory for later playback, review, and analysis on a windows-based PC.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K253293: VitaloJAK Clinic (Model 7100).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K253293

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.