510(k) Report

510(k) · Cleared

Cleared

BioTracker 2.0

K253306510(k) TraditionalCleared Jun 26, 2026270-day review

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Biotracker, LLC

Cleared on Jun 26, 2026 as substantially equivalent to K200141 (Ld Technology, LLC, 2020) and 1 other predicate after a 270-day review. Its family tree reaches back 9 generations to 1991.

Decided
Jun 26, 2026
Review
270 days
Recalls
None
Predicates
2

Its longest line of descent runs back 9 generations to K903134 (1991). 40 ancestors in all, the oldest K853124 (1985). No later device cites it as a predicate yet.

Other ancestors, by year cleared 2020: 1 other ancestor2016: 1 other ancestor2010: 1 other ancestor2008: 2 other ancestors2002: 4 other ancestors2009: 1 other ancestor2006: 1 other ancestor1999: 2 other ancestors1998: 2 other ancestors1997: 2 other ancestors1993: 1 other ancestor2005: 3 other ancestors2003: 1 other ancestor2001: 2 other ancestors1996: 1 other ancestor1995: 1 other ancestor1987: 1 other ancestor2007: 1 other ancestor1992: 1 other ancestor1985: 1 other ancestor2000: 1 other ancestorK903134 · Omron Auto Oscillometric Dig BP Mont/Hem-704C 705C · Omron Marshall Products, Inc. · 1991K970211 · Microlife Automatic Blood Pressure Monitor · Micro Weiss Electronics · 1998K013485 · Microlife Upper Arm Automatic Blood Pressure Monitor, Model BP-3BTO-1, with Optional Thermal Printer, Model PR 1KA1 · Microlife Corp. · 2002K041411 · Microlife Upper Arm Blood Pressure Monitor, Model BP-3BTO-AP · Microlife Corp. · 2004K060686 · Microlife Automatic Blood Pressure Monitor, Model BP3AC1-1PC · Microlife Intellectual Property GmbH · 2006K073198 · Microlife Upper Arm Automatic Digital Blood Pressure Monitor, Model Watchbp Home (BP3MX1-1) · Microlife Intellectual Property GmbH · 2008K082357 · Microlife Upper Arm Automatic Digital Blood Pressure Monitor, Modelwatchbp Office (TWIN200). · Microlife Intellectual Property GmbH · 2008K112845 · Microlife Upper Arm Automatic Digital Blood Pressure Monitor · Microlife Intellectual Property GmbH · 2011K171937 · Microlife Upper Arm Automatic Digital Blood Pressure Monitor · Microlife Intellectual Property GmbH · 20181990200020102020
  1. Root · 9 generations backK903134 Omron Auto Oscillometric Dig BP Mont/Hem-704C 705COmron Marshall Products, Inc. · 1991
  2. 5 generations between
  3. 3 generations backK082357 Microlife Upper Arm Automatic Digital Blood Pressure Monitor…Microlife Intellectual Property GmbH · 2008
  4. 2 generations backK112845 Microlife Upper Arm Automatic Digital Blood Pressure MonitorMicrolife Intellectual Property GmbH · 2011
  5. 1 generation backK171937 Microlife Upper Arm Automatic Digital Blood Pressure MonitorMicrolife Intellectual Property GmbH · 2018
  6. This deviceK253306 BioTracker 2.0Biotracker, LLC · 2026
Show all 9 generations
  1. Root · 9 generations backK903134 Omron Auto Oscillometric Dig BP Mont/Hem-704C 705COmron Marshall Products, Inc. · 1991
  2. 8 generations backK970211 Microlife Automatic Blood Pressure MonitorMicro Weiss Electronics · 1998
  3. 7 generations backK013485 Microlife Upper Arm Automatic Blood Pressure Monitor, Model…Microlife Corp. · 2002
  4. 6 generations backK041411 Microlife Upper Arm Blood Pressure Monitor, Model BP-3BTO-APMicrolife Corp. · 2004
  5. 5 generations backK060686 Microlife Automatic Blood Pressure Monitor, Model BP3AC1-1PCMicrolife Intellectual Property GmbH · 2006
  6. 4 generations backK073198 Microlife Upper Arm Automatic Digital Blood Pressure Monitor, Model…Microlife Intellectual Property GmbH · 2008
  7. 3 generations backK082357 Microlife Upper Arm Automatic Digital Blood Pressure Monitor…Microlife Intellectual Property GmbH · 2008
  8. 2 generations backK112845 Microlife Upper Arm Automatic Digital Blood Pressure MonitorMicrolife Intellectual Property GmbH · 2011
  9. 1 generation backK171937 Microlife Upper Arm Automatic Digital Blood Pressure MonitorMicrolife Intellectual Property GmbH · 2018
  10. This deviceK253306 BioTracker 2.0Biotracker, LLC · 2026
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−9K903134Omron Auto Oscillometric Dig BP Mont/Hem-704C 705COmron Marshall Products, Inc.1991—
−8K970211Microlife Automatic Blood Pressure MonitorMicro Weiss Electronics1998—
−7K013485Microlife Upper Arm Automatic Blood Pressure Monitor, Model BP-3BTO-1, with…Microlife Corp.2002—
−6K041411Microlife Upper Arm Blood Pressure Monitor, Model BP-3BTO-APMicrolife Corp.2004—
−5K060686Microlife Automatic Blood Pressure Monitor, Model BP3AC1-1PCMicrolife Intellectual Property GmbH2006—
−4K073198Microlife Upper Arm Automatic Digital Blood Pressure Monitor, Model Watchbp…Microlife Intellectual Property GmbH2008—
−3K082357Microlife Upper Arm Automatic Digital Blood Pressure Monitor, Modelwatchbp…Microlife Intellectual Property GmbH2008—
−2K112845Microlife Upper Arm Automatic Digital Blood Pressure MonitorMicrolife Intellectual Property GmbH2011—
−1K171937Microlife Upper Arm Automatic Digital Blood Pressure MonitorMicrolife Intellectual Property GmbH2018—
0 (this device)K253306BioTracker 2.0Biotracker, LLC2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198510
198710
199210
199310
199510
199610
199720
199820
199920
200010
200120
200240
200310
200530
200610
200710
200820
200910
201010
201610
202010
FIG. 1 — Lineage of K253306, 1991–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in this category? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K200141Oxi-W System
Summary page 6
…Cardiovascular Primary Predicate Device Predicate Device: Oxi-W System Sponsor LD Technology, LLC 510(K) K200141 Regulation Number: 21 CFR 870.2300, Regulation Name: Cardiac Monitor (including cardiotachometer and rate…
Ld Technology, LLC2020—
*K171937Microlife Upper Arm Automatic Digital Blood Pressure Monitor
Summary page 6
…Monitor, WatchBP Office Central (TWIN200 CBP) Sponsor Microlife Intellectual Property GmbH 510(K) K171937 Regulation Number: 21 CFR 870.1130 Regulation Name: Noninvasive Blood Pressure Measurement System — Micro…
Microlife Intellectual Property GmbH2018—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 35 years and passes through 5 companies; a new generation was cleared every 3.1 years on median.
  • None of the 40 ancestors has a recall.

What is it indicated for?

BioTracker 2.0 is software intended to acquire, display, store, organize, and report physiological data obtained from compatible legally marketed physiological acquisition devices for review by licensed healthcare professionals. The software acquires physiological measurements including oxygen saturation (SpO₂), pulse rate, systolic blood pressure, diastolic blood pressure, and mean arterial pressure (MAP). The software performs mathematical analysis of…

Read the full statement (255 words)

BioTracker 2.0 is software intended to acquire, display, store, organize, and report physiological data obtained from compatible legally marketed physiological acquisition devices for review by licensed healthcare professionals.

The software acquires physiological measurements including oxygen saturation (SpO₂), pulse rate, systolic blood pressure, diastolic blood pressure, and mean arterial pressure (MAP).

The software performs mathematical analysis of the acquired physiological measurements and derived pulse waveform data to calculate the following parameters:

• Ankle-Brachial Index (ABI) (right and left)

• Root Mean Square of Successive Differences (RMSSD)

• Standard Deviation of Normal-to-Normal Intervals (SDNN)

• Percentage of Successive NN Intervals Differing by More Than 50 ms (pNN50)

• Low Frequency/High Frequency Ratio (LF/HF)

• Reflection Index (RI)

• Pulse Wave Amplitude Ratio (PWAR)

• Stiffness Index (SI)

Each calculated parameter is displayed individually together with its corresponding unit of measure. BioTracker 2.0 performs mathematical analysis and presentation of physiological data only. The software does not provide diagnostic interpretations, disease classification, patient risk scores, comparative indicators, alarms, treatment recommendations, or aggregated clinical assessments. Interpretation of the reported physiological measurements and calculated parameters is the responsibility of the licensed healthcare professional.

BioTracker 2.0 is intended for spot-check physiological assessments only. It is not intended for continuous physiological monitoring, real-time patient monitoring, life-support applications, or physiological alarm generation.

BioTracker 2.0 is intended for use in primary care practices, family medicine practices, internal medicine practices, outpatient physician offices, and outpatient healthcare clinics.

BioTracker 2.0 is intended for use by licensed healthcare professionals on adult patients 18 years of age or older.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K253306: BioTracker 2.0.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K253306

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded Oct 30, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026