K253390510(k) TraditionalCleared Jun 27, 2026270-day reviewClass II21 CFR 882.1400

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Honeynaps Co., Ltd. · OLZ Automatic Event Detection Software For Polysomnograph With Electroencephalograph

Cleared on Jun 27, 2026 as substantially equivalent to K223922 (Honeynaps Co., Ltd., 2023) after a 270-day review. Its family tree reaches back 10 generations to 1997.

Decided
Jun 27, 2026
Review
270 days
Class
Class II
Product code
OLZ
Recalls
None
Predicates
1

Its longest line of descent runs back 10 generations to K962603 (1997). 36 ancestors in all, the oldest K873535 (1987). No later device cites it as a predicate yet.

  1. Root · 10 generations backK962603 Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & CablesMasimo Corp. · 1997
  2. 6 generations between
  3. 3 generations backK153412 Sleep ProfilerAdvanced Brain Monitoring, Inc. · 2016
  4. 2 generations backK162627 EnsoSleepEnsodata, Inc. · 2017
  5. 1 generation backK223922 Somnum (V.1.1.2.)Honeynaps Co., Ltd. · 2023
  6. This deviceK253390 Somnum (Somnum)Honeynaps Co., Ltd. · 2026
Show all 10 generations
  1. Root · 10 generations backK962603 Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & CablesMasimo Corp. · 1997
  2. 9 generations backK973887 Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and…Masimo Corp. · 1998
  3. 8 generations backK990966 Masimo Set 2000 Pulse Oximeter, Masimo Lnop -Adt-Adult/Pediatric…Masimo Corp. · 1999
  4. 7 generations backK040595 ALICE 5Respironics, Inc. · 2004 · Recalled
  5. 6 generations backK112102 Michele Sleep Scoring SystemsYounes Sleep Technologies · 2011
  6. 5 generations backK120450 Sleep ProfilerAdvanced Brain Monitoring, Inc. · 2012
  7. 4 generations backK130007 Sleep ProfilerAdvanced Brain Monitoring, Inc. · 2013
  8. 3 generations backK153412 Sleep ProfilerAdvanced Brain Monitoring, Inc. · 2016
  9. 2 generations backK162627 EnsoSleepEnsodata, Inc. · 2017
  10. 1 generation backK223922 Somnum (V.1.1.2.)Honeynaps Co., Ltd. · 2023
  11. This deviceK253390 Somnum (Somnum)Honeynaps Co., Ltd. · 2026
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−10K962603Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & CablesMasimo Corp.1997—
−9K973887Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and CablesMasimo Corp.1998—
−8K990966Masimo Set 2000 Pulse Oximeter, Masimo Lnop -Adt-Adult/Pediatric Disposable…Masimo Corp.1999—
−7K040595ALICE 5Respironics, Inc.20041
−6K112102Michele Sleep Scoring SystemsYounes Sleep Technologies2011—
−5K120450Sleep ProfilerAdvanced Brain Monitoring, Inc.2012—
−4K130007Sleep ProfilerAdvanced Brain Monitoring, Inc.2013—
−3K153412Sleep ProfilerAdvanced Brain Monitoring, Inc.2016—
−2K162627EnsoSleepEnsodata, Inc.2017—
−1K223922Somnum (V.1.1.2.)Honeynaps Co., Ltd.2023—
0 (this device)K253390Somnum (Somnum)Honeynaps Co., Ltd.2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198710
199210
199420
199620
199720
200020
200120
200210
200320
200420
200720
200810
200930
201120
201210
FIG. 1 — Lineage of K253390, 1997–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OLZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OLZ device

  1. #1 K241960 DeepRESPscore 13.8 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K223922Somnum (V.1.1.2.)
Summary page 5
…view Panel Neurology 3. Predicated Device and Reference Device Information 3.1 Predicated Device 510(k) Number K223922 Applicant Honeynaps Co., Ltd Device Name SOMNUM (V.1.1.2.) Confidenti…
Honeynaps Co., Ltd.2023—
†K210034EnsoSleepEnsodata, Inc.2021—
†K112102Michele Sleep Scoring SystemsYounes Sleep Technologies2011—
†K162627EnsoSleepEnsodata, Inc.2017—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 29 years and passes through 6 companies; a new generation was cleared every 2.9 years on median.
  • 2 of the 36 ancestors have a recall of any class.

How does its category compare?

All OLZ devices

OLZ Automatic Event Detection Software For Polysomnograph With Electroencephalograph: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.

FDA decisions per year · OLZ

4in 2025

2007: 12011: 12012: 12013: 12015: 22016: 32017: 22018: 12019: 22020: 12021: 12022: 12023: 22024: 22025: 42026 (partial year): 3
2007high 4 (2025) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OLZ

185in 2025

2016: 122 days median2025: 185 days median2026 (partial year): 155 days median
2007high 185 (2025) · low 122 (2016)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · OLZ

No recall names OLZ since 2007.

Adverse event reports per year · OLZ

3in 2025

2016: 12022: 22023: 12024: 22025: 3
2007high 3 (2025) · low 0 (2007)2025

MAUDE reports naming product code OLZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20080—00
20090—00
20100—00
20111—00
20121—00
20131—00
20140—00
20152—00
2016312201
20172—00
20181—00
20192—00
20201—00
20211—00
20221—02
20232—01
20242—02
2025418503
202631550—

What is it indicated for?

SOMNUM is an Al-enabled software program intended for use as an aid in the diagnosis of sleep and respiratory-related sleep disorders. SOMNUM is intended to be used for analysis — including automatic scoring using Al/ML algorithms for sleep stage classification, arousal detection, respiratory event detection, and leg movement event detection, as well as manual scoring/re-scoring, display, redisplay (retrieve), summarization, and report generation of digital data collected by monitoring devices typically used to evaluate sleep and respiratory-related sleep disorders.

The device is to be used under the supervision of a physician. Use is restricted to data obtained from adult patients.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K253390: Somnum (Somnum).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K253390

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded Oct 30, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026