510(k) Report

510(k) · Cleared

Cleared

CORUS™ Posterior Cervical Stabilization System 3D (CORUS™ PCSS 3D)

K253676510(k) TraditionalCleared May 14, 2026174-day reviewClass U

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Providence Medical Technology, Inc. · MRW System, Facet Screw Spinal Device

Cleared on May 14, 2026 as substantially equivalent to K241035 (Providence Medical Technology, Inc., 2024) after a 174-day review. Its family tree reaches back 8 generations to 1997.

Decided
May 14, 2026
Review
174 days
Class
Class U
Product code
MRW
Recalls
None
Predicates
1

Its longest line of descent runs back 8 generations to K953076 (1997). 16 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 8 generations backK953076 Townley Facet/Pedicular Screw Plating SystemSofamor Danek USA,Inc. · 1997
  2. 7 generations backK051856 TRANS1 Facet ScrewsTrans1 Incorporated · 2005
  3. 6 generations backK073515 TRANS1 Facet ScrewTrans1 Incorporated · 2008
  4. 5 generations backK092568 Spartan S3 Facet SystemAmendia, Inc. · 2009
  5. 4 generations backK120340 Venus Facet Screw SystemApollo Spine, Inc. · 2012
  6. 3 generations backK183589 PMT Facet ScrewProvidence Medical Technology, Inc. · 2019
  7. 2 generations backK220951 PMT Facet Fixation System (PMT FFS)Providence Medical Technology, Inc. · 2022
  8. 1 generation backK241035 PMT Posterior Cervical Stabilization System (PCSS)Providence Medical Technology, Inc. · 2024
  9. This deviceK253676 CORUS™ Posterior Cervical Stabilization System 3D (CORUS™ PCSS 3D)Providence Medical Technology, Inc. · 2026
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−8K953076Townley Facet/Pedicular Screw Plating SystemSofamor Danek USA,Inc.1997—
−7K051856TRANS1 Facet ScrewsTrans1 Incorporated2005—
−6K073515TRANS1 Facet ScrewTrans1 Incorporated2008—
−5K092568Spartan S3 Facet SystemAmendia, Inc.2009—
−4K120340Venus Facet Screw SystemApollo Spine, Inc.2012—
−3K183589PMT Facet ScrewProvidence Medical Technology, Inc.2019—
−2K220951PMT Facet Fixation System (PMT FFS)Providence Medical Technology, Inc.2022—
−1K241035PMT Posterior Cervical Stabilization System (PCSS)Providence Medical Technology, Inc.2024—
0 (this device)K253676CORUS™ Posterior Cervical Stabilization System 3D (CORUS™ PCSS 3D)Providence Medical Technology, Inc.2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200010
200120
200210
200310
200510
200810
201010
FIG. 1 — Lineage of K253676, 1997–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MRW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MRW device

  1. #1 K230840 PMT Facet Fixation System, Lumbar (PMT FFS-LX)score 26.0 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K241035PMT Posterior Cervical Stabilization System (PCSS)
Summary page 5
…edic and Rehabilitation Devices Panel Predicate Device: PMT Posterior Cervical Stabilization System (PCSS), K241035 Reference Device: iFuse Implant System; iFuse-3D Implant, K162733 P…
Providence Medical Technology, Inc.2024—
†K162733iFuse Implant System® - iFuse-3D implantSI-BONE, Inc.2017—
†K230297PMT Expandable Cage (PMT EXP)Providence Medical Technology, Inc.2023—

Also cleared against K241035: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 29 years and passes through 5 companies; a new generation was cleared every 2.9 years on median.
  • 1 of the 16 ancestors has a recall of any class.
  • 2 other devices also cite its predicate K241035.

How does its category compare?

All MRW devices

MRW System, Facet Screw Spinal Device: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.

FDA decisions per year · MRW

7in 2025

2008: 32009: 62010: 62011: 32012: 42013: 72015: 22016: 22017: 12018: 22019: 32022: 32023: 32024: 72025: 72026 (partial year): 5
2007high 7 (2013) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MRW

97in 2025

2008: 88 days median2009: 89 days median2010: 108 days median2011: 122 days median2012: 119 days median2013: 110 days median2019: 90 days median2022: 252 days median2023: 190 days median2024: 50 days median2025: 97 days median2026 (partial year): 169 days median
2007high 252 (2022) · low 50 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MRW

3in 2011

2011: 3
2007high 3 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MRW

3in 2025

2007: 12009: 22010: 72011: 622012: 62013: 42014: 12015: 22016: 12017: 42018: 42021: 12023: 12024: 22025: 3
2007high 62 (2011) · low 0 (2008)2025

MAUDE reports naming product code MRW, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—01
200838800
200968902
2010610807
20113122362
2012411906
2013711004
20140—01
20152—02
20162—01
20171—04
20182—04
201939000
20200—00
20210—01
2022325200
2023319001
202475002
202579703
202651690—

What is it indicated for?

CORUS™ Posterior Cervical Stabilization System 3D (CORUS™ PCSS 3D) is posterior spinal instrumentation with integrated screw fixation intended to provide immobilization and stabilization of spinal segments. CORUS PCSS 3D is placed through a posterior surgical approach in up to 3 consecutive levels of the cervical spine (C3-C7) and achieves bilateral facet fixation by spanning the facet interspace at each level with points of fixation at each end of the…

Read the full statement (153 words)

CORUS™ Posterior Cervical Stabilization System 3D (CORUS™ PCSS 3D) is posterior spinal instrumentation with integrated screw fixation intended to provide immobilization and stabilization of spinal segments.

CORUS PCSS 3D is placed through a posterior surgical approach in up to 3 consecutive levels of the cervical spine (C3-C7) and achieves bilateral facet fixation by spanning the facet interspace at each level with points of fixation at each end of the construct.

CORUS PCSS 3D is intended as an adjunct to posterior cervical fusion (PCF) and is only intended to be used in combination with FDA cleared/approved spine stabilization hardware for anterior cervical fusion at the same level(s).

CORUS PCSS 3D is indicated for skeletally mature patients with degenerative disc disease (DDD). DDD is defined as radiculopathy and/or myelopathy, neck and/or arm pain of discogenic origin as confirmed by radiographic studies.

CORUS PCSS 3D is to be used with autogenous bone and/or allogenic bone graft.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K253676: CORUS™ Posterior Cervical Stabilization System 3D (CORUS™ PCSS 3D).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K253676

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded Oct 30, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026