# K253739: SCRIPT™ Rods, CREO™ Stabilization System,  REVERE® Stabilization System, REVERE® 4.5 Stabilization System, NuVasive Reline™ System

- Pathway: 510(k) (Traditional)
- Applicant: Globus Medical, Inc.
- Decided: May 7, 2026 after 164 days
- Product code: NKB (Thoracolumbosacral Pedicle Screw System)
- Device class: 2
- Regulation: 21 CFR 888.3070
- Recalls of this device: none
- Data: FDA decisions to Oct 25, 2026; recalls to Oct 12, 2026

## Lineage
Longest line of descent: 24 generations back to K040583 (2004). 911 ancestors in all.
No later device cites it as a predicate yet.
7 of 912 devices in its family (counting itself) have a Class I recall.

## Predicates on the family tree (from the FDA summary)
- K124058: Creo Stabilization System, Globus Medical, Inc. (2013) Summary page 8.
- K143633: CREO Stabilization System, Globus Medical, Inc. (2015) Summary page 8.
- K203153: CREO Stabilization System, Navigation Instruments, ExcelsiusGPS, Globus Medical, Inc. (2021) Summary page 8.
- K061202: Revere Stabilization System, Globus Medical, Inc. (2006) Summary page 8.
- K133350: Revere Stabilization System, Globus Medical, Inc. (2014) Summary page 8.
- K181068: CREO® Stabilization System, REVERE® Stabilization System, Globus Medical, Inc. (2018) Summary page 8.
- K113395: Revere 4.5 Stabilization System, Globus Medical, Inc. (2012) Summary page 8.
- K132014: GSB Global Spinal Balance System, Nuvasive, Inc. (2013) Summary page 8.
- K223181: NuVasive Reline System, Nu Vasive, Incorporated (2023) Summary page 8.
- K140738: Pass LP Spinal System, Medicrea International (2014) Summary page 8.
- K220724: CD Horizon™ Spinal System and PASS LP™ Spinal System, Medicrea International (2022) Summary page 8.

## Indications for use
CREO™ Stabilization System implants are non-cervical spinal fixation devices intended for posterior pedicle screw fixation (T1-S2/ilium), posterior hook fixation (T1-L5), or anterolateral fixation (T8-L5). Pedicle screw fixation is indicated for skeletally mature patients (including small stature) and for pediatric patients. These devices are indicated as an adjunct to fusion for the following indications: degenerative disc disease (defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis, Scheuermann’s Disease), tumor, stenosis, and failed previous fusion (pseudoarthrosis). When used as an adjunct to fusion, the CREO™ Stabilization System is intended to be used with autograft and/or allograft. In addition, the CREO™ Stabilization System is intended for treatment of severe spondylolisthesis (Grades 3 and 4) of the L5-S1 vertebra in skeletally mature patients receiving fusion by autogenous bone graft, having implants attached to the lumbosacral spine and/or ilium with removal of the implants after attainment of a solid fusion. Levels of pedicle screw fixation for these patients are L3-sacrum/ilium. When used for posterior non-cervical pedicle screw fixation in pediatric patients, the CREO™ Stabilization System implants are indicated as an adjunct to fusion to treat adolescent idiopathic scoliosis. The CREO™ Stabilization System is intended to be used with autograft and/or allograft. Pediatric pedicle screw fixation is limited to a posterior approach. In order to achieve additional levels of fixation, the CREO™ Stabilization System rods may be connected to the REVERE™ Stabilization System (4.5mm, 5.5mm, or 6.35mm rod) or ELLIPSE™ Occipito-Cervico-Thoracic Spinal System (3.5mm rod) using corresponding connectors. Refer to the REVERE™, or ELLIPSE™ system package insert for instructions and indications of use. In-Line Connector Growing Rods are indicated in patients under 10 years of age with potential for additional spine growth who require surgical treatment to obtain and maintain correction of severe, progressive, life-threatening, early onset spinal deformities associated with thoracic insufficiency, including early onset scoliosis, as part of a growing rod construct. Globus Navigation Instruments are intended to be used during the preparation and placement of CREO® screws during spinal surgery to assist the surgeon in precisely locating anatomical structures in either open or minimally invasive procedures. These instruments are designed for use with the Medtronic StealthStation® System, which is indicated for any medical condition in which the use of stereotactic surgery may be appropriate, and where reference to a rigid anatomical structure, such as a skull, a long bone, or vertebra, can be identified relative to a CT or MR based model, fluoroscopy images, or digitized landmarks of the anatomy. When used for posterior fixation in conjunction with FORTRESS™ or FORTRESS-Plus™ bone cement, the CREO™ Fenestrated Screw System is intended to restore the integrity of the spinal column even in the absence of fusion for a limited time period in patients with advanced stage tumors involving the thoracic and lumbar spine in whom life expectancy is of insufficient duration to permit achievement of fusion. CREO™ Fenestrated screws augmented with FORTRESS™ and FORTRESS-Plus™ bone cements are for use at spinal levels where the structural integrity of the spine is not severely compromised. The REVERE® Stabilization System, when used as a posterior pedicle screw system, is intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar and sacral spine: degenerative disc disease (defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies), degenerative spondylolisthesis with objective evidence of neurologic impairment, fracture, dislocation, scoliosis, kyphosis, spinal tumor, pseudoarthrosis and failed previous fusion. In addition, the REVERE® Stabilization System is intended for treatment of severe spondylolisthesis (Grades 3 and 4) of the L5-S1 vertebra in skeletally mature patients receiving fusion by autogenous bone graft, having implants attached to the lumbosacral spine and/or ilium with removal of the implants after attainment of a solid fusion. Levels of pedicle screw fixation for these patients are L3-sacrum/ilium. When used as a posterior non-pedicle screw fixation system, the REVERE® Stabilization System is intended for the treatment of degenerative disc disease (defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies), spinal stenosis, spondylolisthesis, spinal deformities (i.e. scoliosis, kyphosis, and/or lordosis, Scheuermann’s disease), fracture, pseudarthrosis, tumor resection, and/or failed previous fusion. Overall levels of fixation are T1-sacrum/ilium. When used as an anterolateral thoracolumbar system, the REVERE® Stabilization System is intended for anterolateral screw (with or without staples or staple plates) fixation for the following indications: degenerative disc disease (defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies), spinal stenosis, spondylolisthesis, spinal deformities (i.e. scoliosis, kyphosis, and/or lordosis), fracture or dislocation of the thoracolumbar spine, pseudoarthrosis, tumor resection, and/or failed previous fusion. Levels of screw fixation are T8-L5. In-Line Connector Growing Rods are indicated in patients under 10years of age with potential for additional spine growth who require surgical treatment to obtain and maintain correction of severe, progressive, life-threatening, early onset spinal deformities associated with thoracic insufficiency, including early onset scoliosis, as part of a growing rod construct. Globus Navigation Instruments are intended to be used during the preparation and placement of REVERE® screws during spinal surgery to assist the surgeon in precisely locating anatomical structures in either open or minimally invasive procedures. These instruments are designed for use with the Medtronic StealthStation® System, which is indicated for any medical condition in which the use of stereotactic surgery may be appropriate, and where reference to a rigid anatomical structure, such as a skull, a long bone, or vertebra, can be identified relative to a CT or MR based model, fluoroscopy images, or digitized landmarks of the anatomy. The REVERE® 4.5 Stabilization System implants are non-cervical spinal fixation devices intended for posterior pedicle screw fixation (T1-S2/ilium), posterior hook fixation (T1-L5), or anterolateral fixation (T8-L5). Pedicle screw fixation is indicated for skeletally mature patients (including small stature) and pediatric patients. These devices are indicated as an adjunct to fusion for all of the following indications: degenerative disc disease (defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis, Scheuermann’s Disease), tumor, stenosis, and failed previous fusion (pseudoarthrosis). When used for posterior non-cervical pedicle screw fixation in pediatric patients, the REVERE® 4.5 Stabilization System implants are indicated as an adjunct to fusion to treat adolescent idiopathic scoliosis. The REVERE® 4.5 Stabilization System is intended to be used with autograft and/or allograft. Pediatric pedicle screw fixation is limited to a posterior approach. In order to achieve additional levels of fixation in skeletally mature patients, the REVERE® 4.5 Stabilization System rods may be connected to the REVERE® Stabilization System (5.5mm or 6.35mm rod) or ELLIPSE® Occipito-Cervico-Thoracic Spinal System (3.5mm rod) using corresponding connectors. Refer to the REVERE® or ELLIPSE® system package insert for instructions and indications of use. In-Line Connector Growing Rods are indicated in patients under 10years of age with potential for additional spine growth who require surgical treatment to obtain and maintain correction of severe, progressive, life-threatening, early onset spinal deformities associated with thoracic insufficiency, including early onset scoliosis, as part of a growing rod construct. When used as a pedicle screw fixation system in skeletally mature patients, the NuVasive Reline System is intended to provide immobilization and stabilization of spinal segments as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the posterior thoracic, lumbar, and sacral spine: 1. Degenerative disc disease (as defined by back pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies) 2. Degenerative spondylolisthesis with objective evidence of neurologic impairment 3. Fracture 4. Dislocation 5. Scoliosis 6. Kyphosis 7. Spinal tumor and/or 8. Failed previous fusion (pseudoarthrosis) The NuVasive Reline System is also indicated for the treatment of severe spondylolisthesis (Grades 3 and 4) of the L5-S1 vertebral joint in skeletally mature patients receiving fusion by autogenous bone graft, having the device fixed or attached to the lumbar and sacral spine (L3 to sacrum), with removal of the implants after attainment of a solid fusion. When used as an anterolateral non-pedicle screw system in the thoracic and lumbar spine, the NuVasive Reline System is also intended for the following indications: 1. Degenerative disc disease (as defined by back pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), 2. Spinal stenosis, 3. Spondylolisthesis, 4. Spinal deformities, 5. Fracture, 6. Pseudoarthrosis 7. Tumor resection and/or 8. Failed previous fusion When used for posterior non-cervical screw fixation in pediatric patients, NuVasive Reline System is indicated as an adjunct to fusion to treat: 1. Adolescent idiopathic scoliosis 2. Progressive spinal deformities (i.e., scoliosis, kyphosis, or lordosis) including infantile and juvenile idiopathic scoliosis, neuromuscular scoliosis, and congenital scoliosis 3. Spondylolisthesis 4. Spondylolysis 5. Pseudarthrosis 6. Failed prior fusion and 7. Fracture caused by tumor and/or trauma in pediatric patients Pediatric pedicle screw fixation is limited to a posterior approach and is intended to be used with autograft and/or allograft. In order to achieve additional levels of fixation, the Reline System rods may be connected to the Armada System.