510(k) Report

510(k) · Cleared

Cleared

Veineo System (00MEDRF4000TCUS 05CR45iT 06Pedal1St)

K253918510(k) TraditionalCleared Jun 2, 2026176-day reviewClass II21 CFR 878.4400

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

F Care Systems USA, LLC · GEI Electrosurgical, Cutting & Coagulation & Accessories

Cleared on Jun 2, 2026 as substantially equivalent to K111887 (Covidien, 2011) and 1 other predicate after a 176-day review. Its family tree reaches back 10 generations to 1995.

Decided
Jun 2, 2026
Review
176 days
Class
Class II
Product code
GEI
Recalls
None
Predicates
2

Its longest line of descent runs back 10 generations to K943450 (1995). 27 ancestors in all, the oldest K800617 (1980). No later device cites it as a predicate yet.

  1. Root · 10 generations backK943450 Arthrocare Arthroscopic Electrosurgery System Model 970Arthrocare Corp. · 1995
  2. 6 generations between
  3. 3 generations backK030557 Modification to Vnus Closure SystemVnus Medical Technologies, Inc. · 2003
  4. 2 generations backK061373 Vnus Closurefast Catheter, Models CF7-7-60 and CF7-7-100Vnus Medical Technologies, Inc. · 2006 · Recalled
  5. 1 generation backK111887 Closurefast Radiofrequency CatheterCovidien · 2011
  6. This deviceK253918 Veineo System (00MEDRF4000TCUS 05CR45iT 06Pedal1St)F Care Systems USA, LLC · 2026
Show all 10 generations
  1. Root · 10 generations backK943450 Arthrocare Arthroscopic Electrosurgery System Model 970Arthrocare Corp. · 1995
  2. 9 generations backK961069 Arthrocare Urologic Multi-Electrode Electrosurgery SystemArthrocare Corp. · 1996
  3. 8 generations backK962445 Arthrocare Dental Electrosurgery SystemArthrocare Corp. · 1996
  4. 7 generations backK964849 Arthrocare Dermatologic Electrosurgery SystemArthrocare Corp. · 1997
  5. 6 generations backK971532 Arthrocare Electrosurgery SystemArthrocare Corp. · 1997
  6. 5 generations backK974521 Vnus Closure SystemVnus Medical Technologies, Inc. · 1998
  7. 4 generations backK982816 Vnus Closure SystemVnus Medical Technologies, Inc. · 1999
  8. 3 generations backK030557 Modification to Vnus Closure SystemVnus Medical Technologies, Inc. · 2003
  9. 2 generations backK061373 Vnus Closurefast Catheter, Models CF7-7-60 and CF7-7-100Vnus Medical Technologies, Inc. · 2006 · Recalled
  10. 1 generation backK111887 Closurefast Radiofrequency CatheterCovidien · 2011
  11. This deviceK253918 Veineo System (00MEDRF4000TCUS 05CR45iT 06Pedal1St)F Care Systems USA, LLC · 2026
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−10K943450Arthrocare Arthroscopic Electrosurgery System Model 970Arthrocare Corp.1995—
−9K961069Arthrocare Urologic Multi-Electrode Electrosurgery SystemArthrocare Corp.1996—
−8K962445Arthrocare Dental Electrosurgery SystemArthrocare Corp.1996—
−7K964849Arthrocare Dermatologic Electrosurgery SystemArthrocare Corp.1997—
−6K971532Arthrocare Electrosurgery SystemArthrocare Corp.1997—
−5K974521Vnus Closure SystemVnus Medical Technologies, Inc.1998—
−4K982816Vnus Closure SystemVnus Medical Technologies, Inc.1999—
−3K030557Modification to Vnus Closure SystemVnus Medical Technologies, Inc.2003—
−2K061373Vnus Closurefast Catheter, Models CF7-7-60 and CF7-7-100Vnus Medical Technologies, Inc.20062
−1K111887Closurefast Radiofrequency CatheterCovidien2011—
0 (this device)K253918Veineo System (00MEDRF4000TCUS 05CR45iT 06Pedal1St)F Care Systems USA, LLC2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198010
198510
199520
199640
199760
200010
200410
201410
FIG. 1 — Lineage of K253918, 1995–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GEI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GEI device

  1. #1 K231790 The InMode System with the Morpheus8 Applicatorsscore 32.7 · 21 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K111887Closurefast Radiofrequency Catheter
Summary page 6
…Table 1: Device Identification Legally Marketed Equivalent Device: 510(K) Number Device Name Manufacturer K111887 CLOSUREFAST COVIDIEN RADIOFREQUENCY CA…
Covidien2011—
*K141858Closurerfg Radiofrequency Generator
Summary page 6
…ufacturer K111887 CLOSUREFAST COVIDIEN RADIOFREQUENCY CATHETER K141858 ClosureRFG Radiofrequency COVIDIEN Generator T…
Covidien2014—

Also cleared against K111887: 5 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 31 years and passes through 4 companies; a new generation was cleared every 1.2 years on median.
  • 2 of the 27 ancestors have a recall of any class.
  • 5 other devices also cite its predicate K111887.

How does its category compare?

All GEI devices

GEI Electrosurgical, Cutting & Coagulation & Accessories: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.

FDA decisions per year · GEI

52in 2025

2007: 502008: 612009: 422010: 462011: 352012: 392013: 482014: 492015: 472016: 642017: 522018: 472019: 482020: 592021: 462022: 552023: 652024: 592025: 522026 (partial year): 43
2007high 65 (2023) · low 35 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GEI

113in 2025

2007: 51 days median2008: 71 days median2009: 130 days median2010: 109 days median2011: 135 days median2012: 133 days median2013: 136 days median2014: 103 days median2015: 123 days median2016: 108 days median2017: 72 days median2018: 93 days median2019: 93 days median2020: 105 days median2021: 146 days median2022: 150 days median2023: 104 days median2024: 125 days median2025: 113 days median2026 (partial year): 183 days median
2007high 183 (2026) · low 51 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GEI

4in 2025

2007: 212008: 192009: 272010: 512011: 322012: 302013: 132014: 32015: 42016: 32017: 22018: 62019: 52020: 12021: 62022: 492023: 27, 4 Class I2024: 22, 10 Class I2025: 42026 (partial year): 8
2007high 51 (2010) · low 1 (2020)2026

Class I (14 since 2007) Class II/III not classified

Adverse event reports per year · GEI

7,592in 2025

2007: 2,7952008: 2,5562009: 3,5912010: 3,3772011: 4,4632012: 5,2162013: 4,8972014: 4,9082015: 4,9362016: 5,6162017: 6,0732018: 6,5452019: 7,0672020: 6,4902021: 6,3542022: 6,1032023: 7,1762024: 7,8972025: 7,592
2007high 7,897 (2024) · low 2,556 (2008)2025

MAUDE reports naming product code GEI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20075051212,795
20086171192,556
200942130273,591
201046109513,377
201135135324,463
201239133305,216
201348136134,897
20144910334,908
20154712344,936
20166410835,616
2017527226,073
2018479366,545
2019489357,067
20205910516,490
20214614666,354
202255150496,103
20236510427 (4)7,176
20245912522 (10)7,897
20255211347,592
2026431838—

What is it indicated for?

The Veineo System is intended for endovascular coagulation of blood vessels in patients with superficial vein reflux. The devices are prescription use (Rx) devices.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K253918: Veineo System (00MEDRF4000TCUS 05CR45iT 06Pedal1St).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K253918

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded Oct 30, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026